ページ1に含まれる内容の要旨 
                    
                        DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Models:
FL92 Multi-Sided
Wood Burning Fireplace
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand • Leave this manual with 
• Important operating 
and follow these party responsible for 
and maintenance 
instructions for safe use and operation.
instructions included.
installation and 
operation.
WARNING
WARNING
HOT SURFACES!
If the information in these instruc-
tions is not followed exactly, a Screen/mesh, glass doors 
and other surface
                    
                    ページ2に含まれる内容の要旨 
                    
                        Read this manual before installing or operating this fi replace. Please retain this owner’s manual for future reference. Congratulations! Congratulations on selecting a Heatilator wood burning This owner’s manual should be retained for future refer- fi replace. The Heatilator fi replace you have selected is ence. We suggest you keep it with your other important  designed to provide the utmost in safety and reliability. documents and product manuals. As the owner of a new fi replace, you’ll want to r
                    
                    ページ3に含まれる内容の要旨 
                    
                         Safety Alert Key: ! • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Indicates practices which may cause damage to the fi replace or to property. Table of Contents Congratulations! 2 7 Installation of Fireplace  21 Limite
                    
                    ページ4に含まれる内容の要旨 
                    
                        Limited Warranty Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood,  pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or  Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.  Warranty Period HHT Manufactured Appliances and Venting Components Covered EPA Parts La
                    
                    ページ5に含まれる内容の要旨 
                    
                        This limited warranty does not extend to or include surface ?nish on the appliance or terminations, door gasketing, glass  gasketing, glass discoloration, ?rebrick, pellet logs, kaowool or other ceramic insulating materials.  Rust and/or corrosion  on any of the metal surfaces, cast iron components, baf?es, ?repots, doors, or ?rebox area are not covered by this  warranty. Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to  this noi
                    
                    ページ6に含まれる内容の要旨 
                    
                        Listing and Code Approvals  1 1   B. Non-Combustible Materials A. Appliance Certifi cation • Materials which will not ignite and burn, composed of  any combination of the following: This fi replace system has been tested and listed in accor- - Steel  - Iron dance with UL 127 standards by Underwriters Laborato- - Brick  - Tile ries Inc. for installation and operation in the United States. - Concrete - Slate This fi replace may be installed in sleeping rooms EX- - Glass - Plasters CEPT in manufacture
                    
                    ページ7に含まれる内容の要旨 
                    
                        User Guide Operating Instructions  2 2   WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. • DO NOT touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fi replace. • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other fl ammable materials. • Keep clothing, furniture, draperies and other fl ammable 
                    
                    ページ8に含まれる内容の要旨 
                    
                        B. Seasoned Wood D. Grate Properly seasoned wood is important for successful This fi replace is designed to be used with the grate sup- operation of your fi replace. Most woodburning fi replace plied with this unit or one approved by HHT. The grate will  problems are caused by burning wet, unseasoned wood. break down over time and will need occasional replace- ment. Seasoned fi rewood is wood that is cut to size, split and air  dried to a moisture content of around 20%.  WARNING! Risk of Fire! Use o
                    
                    ページ9に含まれる内容の要旨 
                    
                        H. Glass Doors J. Vented Gas Log Sets & Gas Log Lighters • Optional • Glass doors are optional. • Vented gas logs or gas log lighters can be installed in  • Refer to Figure 2.2 for how to properly use them. this fi replace. Follow the instructions provided with the   WARNING! Risk of Fire! Install ONLY doors ap- accessory for operation. proved by Hearth & Home Technologies, Inc.  WARNING! Risk of Fire or Asphyxiation!  WARNING! Risk of Fire and Smoke! Fireplaces   • DO NOT install unvented gas lo
                    
                    ページ10に含まれる内容の要旨 
                    
                        M. Wood Fuel Seasoned Wood • Cut logs to size Hardwood vs Softwood • Split to 6 in. (152 mm) or less Your fi replace performance depends on the quality of the  • Air dry to a moisture content of around 20% fi rewood you use.  - Soft wood - about nine months • Seasoned wood contains about 8,000 BTUs per pound  - Hard wood - about eighteen months . • Hard woods are more dense than soft woods.  NOTICE: Seasoning time may vary depending on drying  • Hard woods contain 60% more BTUs than soft woods. co
                    
                    ページ11に含まれる内容の要旨 
                    
                        Maintainance and Service  3 3   B. Chimney Inspection/Cleaning A. Disposal of Ashes Frequency: At least twice a year during heating season  Frequency: When they reach bottom of grate or as recommended by a certifi ed chimney sweep By: Homeowner By: Certifi ed chimney sweep WARNING! Risk of Fire! Ashes could contain hot em- WARNING! Risk of Fire! Ignited creosote is extremely  bers. HOT. Prevent creosote buildup. • Place ashes in a metal container with a tight-fi tting lid. Refer to Figure 3.1 to re
                    
                    ページ12に含まれる内容の要旨 
                    
                        C. Check Firebox Refractory Frequency: After each ash removal By: Homeowner WARNING! Risk of Fire! Inspect fi replace refractory.  Crumbling, deteriorated refractory can allow overheating  of surrounding materials. Expansion and contraction will cause minor cracking of  the refractory. This is normal. The refractory will require  periodic replacement depending on use.  The panels should be replaced if • Cracks exceed ¼ inch (6 mm) in width,  • Metal is exposed behind the refractory, • Large piece
                    
                    ページ13に含まれる内容の要旨 
                    
                        Troubleshooting Guide  4 4   Start Fire Problems Possible Cause Solution Can’t get fi re started Not enough kindling/paper or no Use dry kindling, more paper. Arrange kindling &  Excessive smoke or spillage kindling/paper wood for air movement. Burns too slowly Damper closed/not fully open Open damper. Smolders, sizzles Not enough air for fi re to ignite Check for restricted cap/shroud. Open air kit (if installed). Check for fl ue blockage. Pre-warm fl ue before starting fi re (refer to starting  fi r
                    
                    ページ14に含まれる内容の要旨 
                    
                        ) ) ) ) ) ) Installer Guide Getting Started  5 5  A. Typical Fireplace System Additional lateral NOTICE: support for chimney • Illustrations and photos reflect typical installations  above roof (or enclosed and are for design purposes only. in chase) if needed • Illustrations/diagrams are not drawn to scale. (Section 8) • Actual product may vary from pictures in manual. Termination cap  Non-combustible (Section 8 & 9) roof flashing maintains Storm Collar minimum clearance (Section 8) around chim
                    
                    ページ15に含まれる内容の要旨 
                    
                        B. Design and Installation Considerations D. Negative Pressure WARNING! Risk of Asphyxiation! Negative pressure  NOTICE: Check building codes prior to installation. can cause spillage of combustion fumes and soot. Fire  must draft properly for safe operation. • Installation MUST comply with local, regional, state and  national codes and regulations. Negative pressure results from the imbalance of air avail- • Consult insurance carrier, local building inspector, fi re  able for the fi replace to op
                    
                    ページ16に含まれる内容の要旨 
                    
                        E. Locating Fireplace & Chimney Location of the fi replace and chimney will affect perfor- mance.  • Install within the warm airspace enclosed by the building  envelope. This helps to produce more draft, especially  during lighting and die-down of the fi re. • Penetrate the highest part of the roof. This minimizes  the effects of wind loading. • Locate termination cap away from trees, adjacent  structures, uneven roof lines and other obstructions. • Minimize the use of chimney offsets.  • Consider
                    
                    ページ17に含まれる内容の要旨 
                    
                        F. Tools and Supplies Needed H. Inspect Fireplace and Components WARNING! Risk of Fire and/or Explosion! Damaged  Before beginning the installation be sure the following  parts could impair safe operation. DO NOT install dam- tools and building supplies are available: aged, incomplete or substitute components. Keep fi re- Reciprocating saw Framing material place dry. Pliers Non-combustible sealant • Remove fi replace and components from packaging and  inspect for damage. Hammer Gloves • Vent syste
                    
                    ページ18に含まれる内容の要旨 
                    
                        Framing & Clearances  6 6   A. Select Fireplace Location 12 in. (305 mm)  62 in.  from opening of  Note: 1/2 in. min. (13 mm)  (1575 mm)  fireplace distance from fireplace to  16 in.  combustible materials. (406 mm)  In addition to these  Note: framing dimensions,  also reference the  following sections: 56 in.  (1422 mm) • Clearances • Mantel Projections • Fireplace Dimensions  HEARTH  EXTENSION (shaded) 64 in.  (1626 mm)  Figure 6.1 Fireplace Locations 18 Heatilator • Multi-Sided Woodburning F
                    
                    ページ19に含まれる内容の要旨 
                    
                        B. Clearances WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specifi ed in Fig- ure 6.2. DO NOT pack required air spaces with insulation or other materials. Storm Collar  Roof Flashing  Shaded areas represent 2 in. (51 mm) min. air space clearance required around pipe  (attic) Attic Insulation Shield (insulation) (ceiling) Offset/Return (secured 2 in. (51 mm) min.  with hanger straps) (ceiling) Ceiling Firestop Must have 2 in. (51 mm) minimum clear
                    
                    ページ20に含まれる内容の要旨 
                    
                        39° angle C. Sidewalls/Surrounds • Adjacent combustible sidewalls must be located a minimum of 12 in. (305 mm) from the fi replace opening. • Combustible and noncombustible mantel legs, surrounds and stub walls may be constructed within the gridded area,  Figure 6.3. 4 in. [102 mm] 11.92 in. 36 in. 36 in. 9 3/4 in. [303 mm] [914 mm] [914 mm] [248 mm] (fireplace opening) (fireplace opening 40 in. 40 in. FLUSH [1016 mm] [1016 mm] BRICK FRONT FRONT 12 in. 12 in. [305 mm] [305 mm] Figure 6.3 Mantel L