ページ1に含まれる内容の要旨 
                    
                                                       MODEL FP-BR-10-ZC 
                                        VENT-FREE 
March 2005 
WARNING: If the information in this manual is not followed exactly, a fire or 
explosion may result causing property damage, personal injury or loss of life. 
 
− Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this 
or any other appliance. 
    
      WHAT TO DO IF YOU SMELL GAS 
 
•  Do not try to light any appliance. 
• Do not touch any electri
                    
                    ページ2に含まれる内容の要旨 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ページ3に含まれる内容の要旨 
                    
                          TABLE OF CONTENTS  Safety Information and Warnings ................................................................................. 3  Installation ..................................................................................................................... 6  Fireplace and Framing Dimensions .............................................................................. 7  Fireplace Clearances ............................................................................................
                    
                    ページ4に含まれる内容の要旨 
                    
                          Page 2                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ページ5に含まれる内容の要旨 
                    
                        SAFETY INFORMATION  WARNINGS  IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY  BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THIS APPLIANCE.   IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEATH FROM  BURNS, FIRE,  EXPLOSION, AND CARBON MONOXIDE POISONING.    Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.  If  you have these signs, the heater may not be working properly.  Get fresh air at once!  Have burner  serviced.  
                    
                    ページ6に含まれる内容の要旨 
                    
                        5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure.    6.    What To Do IF You Smell Gas:         Shut off gas  supply.         - Do not try to light any appliance.         - Do not touch any electrical switch; do not use any phone in your building.         - Immediately call your gas supplier from a neighbor’s phone.           Follow the gas supplier’s instructions.         - If you cannot reach your gas supplier, call the fire department.    7
                    
                    ページ7に含まれる内容の要旨 
                    
                        21.  All heater screens must be kept clean when operating the gas logs.    22. .”WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in  sooting and property damage.”      24. Do not use this heater for burning trash or cooking.  Never place matches, paper, garbage, or any  other material on top of logs or into the flames.    24. Do not install or operate this heater in areas where impurities in the air exist (such as tobacco  smoke or heavy cooking grease).  Pa
                    
                    ページ8に含まれる内容の要旨 
                    
                        INSTALLATION    The Model FP-BR10-ZC Vent-Free gas fireplace may be installed in any  room in a Residential home or an After-Market* Manufactured Home.  (Exception:  This appliance may not be installed in a bathroom.)    *  (After Market:  Completion of sale, not for the purpose of resale from the manufacturer).  For After-Market Manufactured Home installation, check with state and local codes.    This appliance is only for use with the type of gas indicated on the rating plate.  This appliance 
                    
                    ページ9に含まれる内容の要旨 
                    
                        Fireplace and Framing Dimensions  (ins.)  25  1/8”  24”  11  5/8” 20  3/8”  26  1/8”  26  1/8”  GAS  LINE  1  3/4”  8”  25  1/8”  13  1/2”  FIGURE 2  WARNING:Installation and repairs should be performed by a qualified service person.  The  appliance should be inspected before use and at least annually by a professional service person.  More frequent cleaning may be required due to excessive lint from carpeting, bedding mate- rial, etc. It is imperative that control compartments, burners and circ
                    
                    ページ10に含まれる内容の要旨 
                    
                        FIREPLACE CLEARANCES  depth.  Alternatively, the carpeting, (vinyl) tile, etc. may be  The fireplace may be placed directly on a combustible floor, against  a combustible wall   at marked clear-ances, or on a raised wooden removed beneath the fireplace before installing.  COMBUSTIBLE MATERIALS MUST NOT BE  platform.  INSTALLED OVER OR TOUCH ANY BLACK  If the fireplace is to be installed on a raised wooden platform, the  PAINTED SURFACE.  DO NOT BLOCK HEAT  platform must be a continuous level sur
                    
                    ページ11に含まれる内容の要旨 
                    
                        FINISHING YOUR FIREPLACE  There is a wide variety of finishing material available Check to see whether man-made brick and stone are  for your fireplace from formal wall treatments with made of non combustible materials before using them  marble and mantels, to rustic wood paneling, stone or on the face of the fireplace.  Some of these products  brick. Non-Combustible materials used in this contain combustible materials.  Combustible wall  installation such as slate, tile, marble, etc. must be at
                    
                    ページ12に含まれる内容の要旨 
                    
                        MANTEL PROFILES FOR ZERO CLEARANCE CABINET  MUST BE FOLLOWED  MANTELS WITH 3/4" BASE CEILING 12" 3-1/2" COMBUSTIBLE 3"  MATERIAL 10" COMBUSTIBLE  MATERIAL 42" 3-1/2" 3/4" 3/4" 3" 2-1/2" STAND OFF LOUVERS 2"  FP-BR10-ZC STAND OFF LOUVERS HOOD 2"  FP-BR10-ZC HOOD Bottom of 3/4" Base or Support Bottom of 3/4" Base or Support must be at least 2-1/2" from top must be Flush with top of Unit of Unit if mantel is 10" wide or more. if mantel is 10" wide or less. MANTELS WITH 2-1/2" BASE SUPPORT 12" COMBU
                    
                    ページ13に含まれる内容の要旨 
                    
                        INSTALLATION OF MODEL FP - BR10- ZC  WITH OPTIONAL WOODEN MANTEL    (1) When choosing the right location for your heater and mantel keep the following in mind:  NOTE:  Due to high temperatures, this  heater should be located out of traffic and away      from furniture and draperies.    NOTE:   Kit No. (PA KDMH10)  Deluxe Wooden Mantel for FP-BR10-ZC.       Kit No. (PA KDM10)    Standard Wooden Mantel for FP-BR10-ZC    CAUTION: THE INSTALLATION MUST CONFORM WITH LOCAL CODES OR,  IN  THE ABSENCE O
                    
                    ページ14に含まれる内容の要旨 
                    
                          TOP MANTEL 1/2" WOOD SCREWS (9) REAR  OF HEATER MANTEL BASE FIGURE 6  Page 12                                                                                                                                                                                                                                                                                                                                                                                                                                     
                    
                    ページ15に含まれる内容の要旨 
                    
                        INSTALLATION        AFTER-MARKET MOBILE HOMES  THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET*, PERMANENTLY  LOCATED, MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY  LOCAL CODES.  *After Market: Completion of sale, not for the purpose of  resale from  the  manufacturer.    THIS APPLIANCE IS ONLY FOR USE WITH  THE TYPE OF GAS INDICATED ON THE  RATING PLATE.  THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER  GASES.    NOTE:  For mobile home installation follow “Installation”, pages 6-1
                    
                    ページ16に含まれる内容の要旨 
                    
                        PRODUCING ADEQUATE  VENTILATION  This section is for residential or manufactured (mobile) installation    “This heater shall not be installed in a confined space or unusually tight construction unless  provisions are provided for adequate combustion and ventilation air.”     The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space   3 whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8m per kw) of the  aggregate input rating of all appliances installed 
                    
                    ページ17に含まれる内容の要旨 
                    
                        DETERMINING FRESH-AIR FLOW FOR   HEATER LOCATION    DETERMINE IF YOU HAVE A CONFINED OR UNCONFINED SPACE    Use  this worksheet to determine if you have confined  or  unconfined space.    SPACE:  Includes the room in which you will install  heater  plus adjoining  rooms with  doorless passageways or ventilation  grills between the rooms.       1.  Determine  the  volume  of the space  (length  x  width  x height).         Length x Width x Height =_________cu.ft.(volume of space)         EXAMPLE:
                    
                    ページ18に含まれる内容の要旨 
                    
                           A.  Rework worksheet, adding the space of an adjoining room.  If the extra space provides an  unconfined space, remove door to adjoining room or add ventilation grills between rooms.  See  “Ventilation Air From Inside Building”, page 21.     B.   Vent room directly to the outdoors.  See “Ventilation  Air From Outdoors”, page 22.     C.  Install a lower BTU/Hr heater, if lower BTU/Hr size  makes room unconfined.    If  the  actual BTU/Hr used is less than the maximum  BTU/Hr  the space  can su
                    
                    ページ19に含まれる内容の要旨 
                    
                        VENTILATION AIR FROM OUTDOORS    Provide extra fresh air by using ventilation grills or ducts.  You must provide two permanent  openings: one within 12" of the ceiling and one within 12" of the floor.  Connect these items  directly to the outdoors.  These spaces include attics and crawl spaces.  Follow the National  Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, “Air For Combustion and Ventilation” for  required size of ventilation grills or ducts.    IMPORTANT:  Do not provide openings for inl
                    
                    ページ20に含まれる内容の要旨 
                    
                        GAS PRESSURE CHECK  Check the inlet pressure to the burner to insure that it is as shown in the table below.    NOTE:  The pressure check point is located on the right side of the valve facing burner.    The appliance and its appliance main gas valve must be disconnected from the gas supply  piping system during any pressure testing of that system at test pressures in excess of 1/2  psi (3.5kPa).    The appliance must be isolated from the gas supply piping system by closing its equipment  shut-o