                        Installation & Operating manual
The harman SF1500A, SF2500A, SF2600A, SF 3500A
r4
SAFETY NOTICE
PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur hEATINg APPlIANCE.  F AIlurE 
TO FOllOw INSTruCTIONS mAY rESul T IN PrOPErTY dAmAgE, bOdIl Y INjur Y, Or EvEN dEATh.
FOr uSE IN ThE u.S. ANd CANAdA.  NOT SuITAblE FOr INSTAllATION IN mObIlE hOmES
IF ThIS hArmAN STOvE IS NOT PrOPErl Y INSTAllEd, A hOuSE FIrE mAY rESul T.  FOr YOur SAFETY, FOl -
lOw INSTAllATION dIrECTIONS.  
CONTACT lOCAl b
                    
                    ページ2に含まれる内容の要旨 
                    
                        Table of Contents Packing List     3 Installation     5 Mounting Blower & Filter Box  7 Wiring      8 Duct Work      Operation      Safety Tips     3 Chimney Troubleshooting   3 Maintenance     4 Specifications	 	 	 	 15 Coil Installation    6  Oil Burner Setup    8 Warranty     9                                                                                                                                                                                                                
                    
                    ページ3に含まれる内容の要旨 
                    
                        Packing list - SF2600 Blue Angel Oil Burner Burner Gasket Automatic Draft Control Blower () Blower Brackets Filter Box Kit (3 pieces) + Filter Fan Control / High Limit 3-Speed Fan Switch (not on SF3500) ()  Thermostats () Junction Boxes Relay High Limit Snap Disc (4) /4 X 3/4 bolts & (4) Filter Box Mounting Clips 36” Flex Conduit () Straight Conduit Fitting  () Elbow Conduit Fitting Filter Ash Pan Shaker Handle Filter Box Kit Owner’s Manual  Warranty Registration Filter Box  Mounting Clips
                    
                    ページ4に含まれる内容の要旨 
                    
                        Packing list for SF1500, SF2500 & SF3500 Blower Mounting Plate w/ = 5/6X3/4 bolts ( SF3500 Only) Automatic Draft Control Blower () Blower Brackets Filter Box Kit (3 pieces) + Filter Fan Control / High Limit 3-Speed Fan Switch (not on SF3500) Thermostat Junction Box Relay (4) /4 X 3/4 bolts & (4) Filter Box Mounting Clips 36” Flex Conduit () Straight Conduit Fitting Filter () Elbow Conduit Fitting Ash Pan Filter Box Kit Shaker Handle Owner’s Manual  Warranty Registration Filter Box  Mountin
                    
                    ページ5に含まれる内容の要旨 
                    
                        Furnace Installation  To ensure a safe installation, it  is recommended that this furnace be  installed by a qualified installer.  The sheet metal top and sides can be  Inspect Gasket prior to re- easily removed to reduce the chance of dents  installing heat exchanger. or scratches on the painted surfaces.  T o	remove	the	sheet	metal,	first	lift	of f	the	top	 section. Now, the sides can be removed by  lifting up and out away from the furnace.    To lighten the SF600, the oil burner  heat exchan
                    
                    ページ6に含まれる内容の要旨 
                    
                        Furnace Installation  Bolt the auto- Installing w ood/Coal high limit Switch-  matic draft control to  SF600 only. the bottom door. Be   First, install the sheet metal sides as de- sure to hold the unit  scribed in the previous section. Install the snap disc  straight while tighten- switch into the hole on the right side sheet metal.  ing. After the auto- Then mount the open backed junction box around  matic draft control  the snap switch. Proceed with wiring as shown on  is mounted, the two  p
                    
                    ページ7に含まれる内容の要旨 
                    
                        Furnace Installation SF2600. 	 This	figure	represents	the	model	SF2600	furnace.	It’ s	intention	is	to	 represent the approximate location of the various controls. This draw- ing may also be used as a reference for wiring and control spacing.  Please	note	that	this	drawing	is	for	reference	only .	Specific	installa- tions will vary. mounting The blower And Filter box 	 Position	the	filter	box	between	the	brackets	on	the	rear	of	the	fur- nace,	with	the	bottom	of	the	box	resting	on	the	flange	at	the
                    
                    ページ8に含まれる内容の要旨 
                    
                        Furnace Installation - w iring w iring 	 Before	beginning	any	wiring,	study	the	appropriate	wiring	diagram	for	your	unit.	 Also	refer	back	to	fig- ures C or D for an example of what the completed job will look like. It is your reponsibility to follow all state  and local electrical codes.  Locate the best place to route the power for the blower, and drill a 7/8” hole in the  filter	box.	 This	hole	size	will	accomodate	a	“romex”	connector .	 Attach	the	blower	and	power	wires	as	shown	on	 the appr
                    
                    ページ9に含まれる内容の要旨 
                    
                        SF3500 w iring diagram SF3500 w iring diagram 9                                                                                                                                                                                                                                                                                                                                                                                                                                                                     
                    
                    ページ10に含まれる内容の要旨 
                    
                        SF2600 w iring diagram SF2600 w iring diagram 0                                                                                                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    ページ11に含まれる内容の要旨 
                    
                        duct w ork and Operating Instructions duct w ork. 	 This	figure	shows	a	typical	duct	 system layout. Be sure the entire sys- tem is properly sized to provide the cor- return Air rect static pressure for optimum blower  Supply Trunk performance. Have any new duct sys- tem designed by a HVAC professional. Plenum Operating Instructions  Adjusting Automatic draft  Control - In order for your new furnace  to function, the controls must be prop- Figure 5 erly adjusted. The heat output is regu- lated b
                    
                    ページ12に含まれる内容の要旨 
                    
                        Operating Instructions SF 2600 - Oil Operation as backup - furnaces may be loaded with wood as full as possible  The SF 600 offers a unique option to the homeowner.  for high output and long burn time. Then close the door  The	 ability	 to	 have	 an	 efficient	 oil	 backup	 heat	 source	 a n d 	 a l l o w 	 a l l 	 t h e 	 w o o d 	 t o 	 c a t c h 	 fi r e . 	 T h e 	 b o t t o m 	 d o o r 	 m a y	 built right into a wood/coal furnace. again be opened to speed the process. The object is to  Th
                    
                    ページ13に含まれる内容の要旨 
                    
                        Operating Instructions/Safety Tips The amount of shaking is critical. Too much will disrupt the nace into the room with possible fatal consequences. fire	bed	and	too	little	will	restrict	the	air	flow . With the exception of start up or increasing heat from a  low	 fire,	 or	 removing	 ashes,	 the	 bottom	 door	 should	 be	 The	 proper	 amount	 normally	 occurs	 when	 red	 coals	 first	 kept closed. Never install a Harman furnace to a chimney  start to drop through the grates into the ash pan. wi
                    
                    ページ14に含まれる内容の要旨 
                    
                        maintenance maintenance warranty  The spiral chamber is basically self-cleaning.  Warranty is issued at time of purchase. For the warranty  However, if there is a draft problem and you have been  to become effective, you must return the activation  burning wood for a long time with little heat demand,  coupon to Harman, 35 Mountain House Rd., Halifax,  the spiral chamber may need cleaning. Soft coal will  Pennsylvania 703   as soon as possible. The model/ also require more frequent cleaning. 
                    
                    ページ15に含まれる内容の要旨 
                    
                        Specifications SF1500 SF2500 SF2600 SF3500 Complete Complete Complete Complete heating Capacity- square ft. 00 300 300 400 Approximate bTu Input 90,000 0,000 0,000 70,000 blower Size 000 cfm  000 cfm 000 cfm 450 cfm Automatic draft Standard Standard Standard Standard Filter box & Filter Standard Standard Standard Standard 3-Speed Fan Switch Standard Standard Standard Single Speed Fan Control / high limit Standard Standard Standard Standard Thermostat Standard Standard Standard Stan
                    
                    ページ16に含まれる内容の要旨 
                    
                        Special Instructions Coil Installation: Cold Water In Hot Water Out Pressure Relief Valve Automatic Air Valve 1 2 5 Pressure Relief Valve  (Must be within    2 feet of coil) 3 3 Existing Water  Rear Of  Heater Furnace 10 Feet Maximum Drain Valve 4 Plumbing diagram For Thermo-Siphon method - maximum distance = 10 Feet Place one of the supplied nuts on each leg of the coil. Place the coil through the holes on the back of  the furnace, and adjust the nuts so that the pipes stick out about ¼ to  ½ 
                    
                    ページ17に含まれる内容の要旨 
                    
                        Special Instructions Cold Water In Hot Water Out Aquastat, close on rise.          Optional Temp. / Pressure Automatic     Relief Valve 8 Air Valve 2 1 7 Pressure Relief Valve - Must be  within 2 ft. of coil 3 3 Drain Optional Gate Valve Valve to Control 5 Rate of Flow 4 6 Circulator Pump Distance between of more than 10 feet Circulating Pump method - distance = 10 Feet or more This method is used when the water heater tank is more than ten feet away from the furnace or the fur- nace is on a hig
                    
                    ページ18に含まれる内容の要旨 
                    
                        SF2600 burner Set up SF2600 Oil burner Setup Nozzle                                                  80 Degree Solid Cone Off Cycle Damper Setting (B)             No. (as low as it goes  Flamelock Setting (A)                                                     No.  Combustion Air (C)                                                No.  to  ¼ Draft - (Inches of water column)                               .06 to .08 Tests for CO² must be made without a fire in the wood/ coal firebox, and with a
                    
                    ページ19に含まれる内容の要旨 
                    
                        1 Year Limited Warranty (Commerical) 5 Year Limited Warranty (Residential)      Warranties are not transferable. Harman Stove Company warrants its products to be free from defects in material  and workmanship, in normal use and service, for five (5) years from the date of sales invoice.       If defective in material or workmanship, and if removed by the owner with in 60 months of installation, Harman  Stove Company will, at its option, repair or replace the product as described below.       The
                    