ページ1に含まれる内容の要旨 
                    
                         
Equinox (8000) 
Wood Stove 
OWNER'S MANUAL 
 
INSTALLATION AND 
OPERATING INSTRUCTIONS 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
PLEASE READ THIS ENTIRE OWNER’S MANUAL BEFORE YOU INSTALL AND USE YOUR 
NEW EQUINOX WOOD STOVE. 
 
SAVE THIS OWNER’S MANUAL FOR FUTURE REFERENCE 
 
To reduce the risk of fire, follow the installation instructions. 
Failure to follow these instructions can result in property damage, 
bodily injury, or even death. 
 
 
CONTACT LOCAL AUTHORITIES WITH JURISDICTION (BUILDING DEPARTMEN
                    
                    ページ2に含まれる内容の要旨 
                    
                          TABLE OF CONTENTS  INTRODUCING YOUR EQUINOX WOOD STOVE.......................................................................... 3  CODES...........................................................................................................................................................3  SAFETY INFORMATION..................................................................................................................................3  Periodic Checklist .................................
                    
                    ページ3に含まれる内容の要旨 
                    
                        
                    
                    ページ4に含まれる内容の要旨 
                    
                           Burn natural wood only. Higher efficiencies and lower   Clean your chimney system as needed. (See page 20)  emissions result when burning air-dried, seasoned wood, as    compared to green or freshly cut wood. Manufactured wood  products may contain adhesives, bonding agents, and PERIODIC CHECKLIST  coatings that can produce dangerous burning conditions and   hazardous fumes.  Perform each of these tasks at, or before the specified    intervals.   Use caution when loading firewood into a hot s
                    
                    ページ5に含まれる内容の要旨 
                    
                        SPECIFICATIONS    Maximum Heat Output  120,000 BTU per hour of cordwood (based on independent  laboratory test results).    Floor Size of Heated Area  Up to a maximum of 3,500 square feet. Factors unique to  your home can reduce the square footage the stove will  heat. Home insulation value, number and efficiency of  windows, floor plan, stove placement, quality of the fuel  and other conditions may limit the heating ability of the    stove.  View 2 - Equinox Top    Firebox Capacity    4.0 cubic
                    
                    ページ6に含まれる内容の要旨 
                    
                        Setting Up Your Equinox Wood Stove    UNPACKING HEARTH REQUIREMENTS AND FLOOR    PROTECTION  HearthStone packages your Equinox stove with the    greatest care so that it ships safely. Under certain Ensure you protect combustible flooring with a covering of  circumstances, however, damage may occur during transit noncombustible material. The floor protection must extend  and handling. When you receive the Equinox, carefully beyond the body of the stove at the minimum as follows:    unpack and ins
                    
                    ページ7に含まれる内容の要旨 
                    
                          structural members of the house. The outside air kit  Noncombustible Material Thickness R-value will attach to the back of the stove.  1 1   Gypsum or plaster board / ″ 0.45  2 The International Residential Code (IRC) does not  Wallboard, Wonderboard, or 0.20  1 / ″  1 2 allow the outside air duct to terminate higher than the  Durock  appliance. Some building officials also do not like to  1 1 Ceramic board (Fiberfrax or Micor) 1.10  / ″  2 see any vertical rise in the duct’s termination.  1 N
                    
                    ページ8に含まれる内容の要旨 
                    
                        COMBUSTIBLE SURFACE REQUIRED CLEARANCES:   It is very important to follow minimum clearances for chimney connectors to combustibles such as walls and ceilings when  installing the stove near combustible surfaces.     MINIMUM CLEARANCES TO COMBUSTIBLES (from closest point of stove)      Figure 3: Freestanding Installation Clearances (US Requirements)      Figure 4: Fireplace Installation Clearances  HearthStone Quality Home Heating Products, Inc ®                                                  
                    
                    ページ9に含まれる内容の要旨 
                    
                          FREESTANDING COMBUSTIBLE SURFACE CLEARANCE DIMENSIONS (Inches)   Parallel Corner  G  Installation type A B C D E F H I J K  No Heat Shield &  21 21 22-3/4 26-3/4 37-1/4 18-1/4 59-3/4 15 26-3/8 30-3/8 76  single wall connector  No Heat Shield &  20 17 18-3/4 22-3/4 36-1/4 14-1/4 55-3/4 14-1/2 25-7/8 29-7/8 75-1/3 double wall connector Rear Heat Shield &  22 8 * 9-3/4 13-3/4 38-1/4 5-1/4 46-3/4 15-1/2 26-7/8 30-7/8 76-3/4 single wall connector  Rear Heat Shield &  19 6 * 7-3/4 11-3/4 35-1/4 3-1/
                    
                    ページ10に含まれる内容の要旨 
                    
                          HearthStone Quality Home Heating Products, Inc ®                                                                                                                                                                      Equinox Model 8000            10                                                                                                                                                                                                                                                            
                    
                    ページ11に含まれる内容の要旨 
                    
                        chimney connector passes to the chimney. It keeps the  VENTING COMPONENTS AND CONFIGURATION  walls from igniting. You must use a wall thimble when  REQUIREMENTS  installing a chimney connector through a combustible    wall to the chimney.     DO NOT CONNECT THIS UNIT TO A CHIMNEY    FLUE SERVING ANOTHER APPLIANCE  • A wall pass-through (or chimney support package) also    keeps the walls from igniting. You must use one when  • Single wall connector that is 24 MSG or 25 MSG blued  connecting thro
                    
                    ページ12に含まれる内容の要旨 
                    
                          In general, you do not need to install a stovepipe damper  with the Equinox. Some installations, however, could Connection to a Masonry Chimney    benefit from a stovepipe damper, such as a tall chimney  Consider two primary elements when connecting your stove  which can create a higher than normal draft. In such cases, a  to a masonry chimney: the chimney itself and the thimble  damper can help regulate the draft. The Equinox requires a  where the stovepipe connects to the chimney. Use only  
                    
                    ページ13に含まれる内容の要旨 
                    
                            Figure 5: Typical Acceptable Chimney Configurations  HearthStone Quality Home Heating Products, Inc ®                                                                                                                                                                      Equinox Model 8000            13                                                                                                                                                                                                     
                    
                    ページ14に含まれる内容の要旨 
                    
                        
                    
                    ページ15に含まれる内容の要旨 
                    
                        INSTALLING IN A MOBILE HOME     Follow these special requirements for installing your stove  in a mobile home.      • Install the stove in accordance with 24 CFR, Part 3280  (HUD).    • A chimney cap spark arrestor is a requirement in  mobile home installations.    • HearthStone recommends you install at least one  smoke detector.    • Permanently attach the stove to your mobile home’s  floor. Use appropriate bolts through the existing holes  in the legs, or use the clips that secured the Equino
                    
                    ページ16に含まれる内容の要旨 
                    
                        
                    
                    ページ17に含まれる内容の要旨 
                    
                        
                    
                    ページ18に含まれる内容の要旨 
                    
                          good, hot fire will clean the glass. We recommend a visual  MEDIUM LOW BURN: With the primary air control in the  inspection (and cleaning if necessary) of your stovepipe and  open, left most position, push the handle about ¾ of the  chimney after the break-in procedure is completed.  distance to the right. A medium-low burn rate is the typical    setting and is preferable if the stove is unattended.   NORMAL OPERATION       LOW BURN: Push the primary air control inward all the way  Prior to l
                    
                    ページ19に含まれる内容の要旨 
                    
                        REMOVAL AND DISPOSAL OF ASHES     Remove ashes only when the stove is cold. Use protective  fireplace gloves if the ash pan is warm. Exercise extreme  caution when handling, storing or disposing of ashes.    The ash pan is behind the ash compartment door located  under the front ash lip. The ash pan collects burned ash from  a fire and allows you to remove the ash conveniently from  your wood stove. Clear the firebox of ashes often, and do not  let them build up too high. It is important to prev
                    
                    ページ20に含まれる内容の要旨 
                    
                        Maintaining Your Equinox Wood Stove     NOTE: ANY SYMPTOMS OF OVER-FIRING FRONT DOOR REMOVAL PROCEDURE:    WILL VOID YOUR WARRANTY!    1. Open the door 45 to 90 degrees.  CREOSOTE FORMATION AND NEED FOR REMOVAL  2. Remove the front door by lifting it straight up off the   hinges with the hinge pins remaining in the door.   When wood burns slowly at low temperatures, it produces tar 3. It may be necessary to apply considerable upward  and other organic vapors, which combine with expelled pressure