ページ1に含まれる内容の要旨 
                    
                        R
Tested and Portland
O-T L
Listed by Oregon USA
C US
5700 WOOD STOVE
OMNI-Test Laboratories, Inc.
Advanced Combustion Technology (ACT)
Owner’s Manual 
VERY IMPORTANT!!
Installation and Operation
BEFORE STARTING 
YOUR FIRST FIRE READ 
HOW TO OPERATE 
Model:
THE 2-STEP DOOR 
HANDLE 
820-0721
ON PAGE 19
This manual contains instructions for Installation, Operation & Maintenance.
Please read this entire manual before you install and use your new room heater.  Failure to follow 
instructions may res
                    
                    ページ2に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  and Welcome to the Quadra-Fire Family! Hearth & Home Technologies welcomes you to our tradition nology to achieve the optimum operation of our stoves, inserts and  of excellence!  In choosing a Quadra-Fire appliance, you have fireplaces.  And yet we are old-fashioned when it comes to crafts- manship.  each unit is meticulously fabricated and surfaces are  our assurance of commitment to quality, durability, and perfor- hand-finished for lasting beauty and enjoyment.  Our p
                    
                    ページ3に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  TABLE OF CONTENTS Listings & Safety Cautions.............................................4 ACCESSSORY / PARTS REPLACEMENT  Installation Materials Needed ........................................4 Ash removal System .................................................. 15 Venting System Overview..............................................4 Pedestal & Leg Kit Installation ..................................... 16 Dimensions .....................................................
                    
                    ページ4に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  LISTINGS & SAFETY CAUTIONS These installation instructions describe the installation and opera- FIRE SAFETY:  To provide reasonable fire safety, the following should  tion of the QUADRA-FIRE 5700 woodstove.  This stove meets the  be given serious consideration: U.S. environmental Protection Agency’s 1990 particulate emission  1. Install at least one smoke detector on each floor of your home  standards.  The 5700 is listed by OMNI-Test Laboratories, Inc. to  to ensure your
                    
                    ページ5に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  DIMENSIONS  26-5/8" (676mm) 33-1/16" (840mm) 10-1/16" 13-5/16" 30-1/4" (768mm) (256mm) (338mm) 17.0" (768mm) C L 11.0" (279mm) 17-1/8" (494mm) back of stove to glass 14-15/16" 29-3/16" (742mm) 21-1/16" (535mm) (379mm) 38-3/4" (984mm) 21-9/16"	 (548mm) 13-11/16"  19-7/16" (494mm) (348mm) 24.0" (610mm) 7-1/4"  26-5/8" (676mm) (184mm) C L 4.0"  4-1/2"  (102mm) (114mm) 35-1/2"  (902mm) 10-7/16"  8-9/16"  (265mm) (217mm) 19-15/16" (506mm) 4-3/16" (106mm) 26-15/16" (684mm) 26-1
                    
                    ページ6に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  CLEARANCES TO COMBUSTIBLES (UL AND ULC) BACkWALL / SIDEWALL  ALCOVE SIDE VIEW A b g A C H * 90° OFF TOP  g UP & OUT CEILING  D B CLEARANCE STOVE TO CEILING  CLEARANCE  CORNER INSTALLATION ALCOVE TOP VIEW  e F C e D F MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS  In Inches and (Millimeters) NOTE:  All “A”, “C” and “F” Dimensions are to the inside diameter of the flue collar. 	 A b C D	 e F g H  INSTALLATION: Full Vertical OR Horizontal with 2 foot minimum vertical Off Stove
                    
                    ページ7に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  FLOOR PROTECTION FLOOR PROTECTION:  Floor protector must be non-combustible material, extending beneath heater and to the front/sides/rear  as indicated.  The floor must be non-combustible or otherwise adequately protected from radiant heat given off by the unit and  from sparks and falling embers.  A layer of thin brick or ceramic tile over a combustible floor is not sufficient.  A listed hearth pad  that has a “k” value of .84 or lower meets this requirement. In US inst
                    
                    ページ8に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  FLOOR PROTECTION (Cont’d)  ALTERNATE MATERIALS WORkSHEET How to determine if alternate floor protection materials are acceptable: All floor protection must be non-combustible (i.e., metals, brick, stone, mineral fiber boards, etc.).  Any organic materials  (i.e., plastics, wood paper products, etc.) are combustible and must not be used.  The floor protection specified includes  some form of thermal designation such as r-value (thermal resistance) or k-factor (thermal cond
                    
                    ページ9に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  CHIMNEY HEIGHT/DRAFT To be sure that your Quadra-Fire stove burns properly, the chimney draft (static pressure) should be approximately -.10”  water column (W.C.) during a high burn and -.04” W.C. during a low burn, measured 6” (152mm) above the top of the stove  after one hour of operation at each burn setting. NOTE:  These are guidelines only, and may vary somewhat for individual installations. Your Quadra-Fire stove was designed for and tested on a 6” (152mm) chimney, 
                    
                    ページ10に含まれる内容の要旨 
                    
                        FIGURE 6 R  5700 ACT Wood Stove  MASONRY CHIMNEY (Cont’d) FLUE SYSTEMS There are two separate and different parts to a flue system: the  The flue should be checked to determine that it is not too  chimney connector and the chimney itself. large for the stove. NFPA 211 allows the cross-sectional  area of the flue to be no more than 3 times the cross- A. Single wall connector or stove pipe.  This must be at least  sectional area of the flue collar of the stove (28 x 3 =  24 gauge mild steel or 26 
                    
                    ページ11に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  SOLID PACk CHIMNEY WITH METAL SUPPORTS AS A THIMBLE For the method of installation to a masonry chimney shown in Figures 13A & 13B on page 13, it will be necessary to pur- chase a 12” (305mm) long 8" (203mm) inside diameter, section of prefabricated Listed solid pack chimney to use as a thimble.   Purchase a wall spacer, trim collar, and a wall band manufactured to fit the chimney section you purchase. The safety features of this system are two fold:   1.  A 2" (51 mm) ai
                    
                    ページ12に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  SOLID PACk CHIMNEY WITH METAL SUPPORTS AS A THIMBLE (Cont’d) First, make the frame for the thimble, ensuring it is no  Min. Chimney Clearance  Min. Clearance  smaller than 14" (356mm) square, to maintain a 2"  to	W all Spacer and  2" (51mm) (51mm) air space around the chimney section. Combustibles - 2" (51mm) 		 1" (25mm) Air  Attach the wall spacer to the chimney side of the  Space to Chimney  Chimney Flue  frame.  Then insert the frame into the opening, toe  Section Lin
                    
                    ページ13に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  CONNECTION TO A METAL PRE-FABRICATED CHIMNEY When a metal prefabricated chimney is used,  Listed  Chimney Attic  the manufacturer’s installation instructions  Listed Cap Insulation  Combustible  must be followed precisely.  You must also  Shield Maintain 2" (51mm)	 Storm Collar Ceiling  Clearance purchase (from the same manufacturer)  Specified  Joists Clearance and install the ceiling support package or  Flashing wall pass-through and “T” section package,  Ceiling  fires
                    
                    ページ14に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  MOBILE HOME INSTALLATION You must use a Quadra-Fire Outside Air kit for installation in a mobile home.   1. An outside air inlet must be provided for combustion and  must remain clear of leaves, debris, ice and/or snow. It  Spark Arestor Cap must be unrestricted while unit is in use to prevent room  air starvation which can cause smoke spillage and an  inability to maintain a fire.  Smoke spillage can also set  off smoke alarms. Storm Collar 2. Stove must be secured to th
                    
                    ページ15に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  ASH REMOVAL SYSTEM (ARS) INSTALLATION ARS OPERATING AND CLEANING 1. Place protective pad or stove pallet on floor. 1. When stove is cool, open front door and brush most  2. Lay body of stove on its back on protective pad or pallet. of the ash into the center of the firebox.  remember  to leave 1/4” to 1/2” (6-13mm) of ash on the firebox  3.  remove ash removal system top and bottom cover plates by  floor to act as a natural grate, allowing air to flow  loosening nuts unde
                    
                    ページ16に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  PEDESTAL OR LEG kIT INSTALLATION WARNING:  DO NOT OPERATE STOVE BEFORE FULLY ASSEMBLING ALL  COMPONENTS.  BURNING YOUR STOVE WITHOUT A PEDESTAL OR LEG  kIT ATTACHED WILL VOID YOUR WARRANTY AND COULD PRESENT A  SAFETY HAZARD. PEDESTAL MODEL 1  Place protective pad or stove pallet on floor. 2. Lay body of stove on its back on protective pad or  pallet. 3. Loosen screws on adapter and slide pedestal over              adapter on bottom of stove           4. Line up holes in s
                    
                    ページ17に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  INSTALLATION OF OPTIONAL BLOWER, 	 Part 831-1701 The blower is shipped fully assembled and ready for installation. 1. remove the three bolts (1/4”-20 Phillips Head) on the outer skin at the bottom rear of stove. 2. Align holes in mounting flange of blower with bolt holes in stove. blower should be positioned around bottom of rear outer  skin as shown in drawing below. 3. re-insert and tighten bolts, securing blower onto outer wall of stove. Do not remove ground from plug.
                    
                    ページ18に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  OUTSIDE AIR kIT INSTALLATION Included in kit: 1 front cover; fiberglass rope; 2 vent  Pedestal Model straps; venting flange & 4 screws; termination cap  & screws.  Not all materials are needed for each  model.   Items Needed for Installation: 4” (102mm)  flex pipe  in the length as required for your installation;  Phillips screwdriver; Silicone sealant; Drills and  saws necessary for cutting holes through the wall  or flooring in your home. Flex  1. remove all materials f
                    
                    ページ19に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  OPERATING INSTRUCTIONS IMPORTANT - PLEASE READ BEFORE USING STOVE BURNING PROCESS and rekindle the next load of wood.  It is best to open the air  controls for a short while before reloading.  This livens up  In	 recent	 years	 there	 has	 been	 an	 increasing	 concern	 about	 air	 the	 coalbed.  Open door slowly so that ash or smoke does  quality.  Much of the blame for poor air quality has been placed  not exit stove through opening.  You should also break up any  on th
                    
                    ページ20に含まれる内容の要旨 
                    
                        R  5700 ACT Wood Stove  OPERATING INSTRUCTIONS (Cont’d) IMPORTANT - PLEASE READ BEFORE USING STOVE For maximum operating efficiency with the lowest emissions, follow these operating procedures: 1. r egardless of desired heat output, when loading stove, burn your Quadra-Fire with both air controls wide open for 5 to  15 minutes. 2. regulate burn rate (heat output) by using the Primary Control (center under ashcatcher).  The Start-Up Air Control (on the  right) is mainly for initial start-up and r