ページ1に含まれる内容の要旨 
                    
                        Stockton 3/4/5/6/7/8/11
Free Standing Stove
Models: 7118/7101/7102/7119/7160/7127/7130/7161/7100/7162/7117/7120/7163/7103/7104/
7105/7113/7113lC/7128/7114/7106/7106lC/7106HC/7116/7116lC/7116HC
Instructions for Use,
Installation and servicing
For use in GB & Ie (Great Britain and Republic of Ireland).
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated 
instructions and in some cases
                    
                    ページ2に含まれる内容の要旨 
                    
                        CoVeRING THe FolloWING Models: 7118/7101/7102/7119/7160/7127/7130/7161/7100/7162/7117/7120/7163/7103/7104/  7105/7113/7113lC/7128/7114/7106/7106lC/7106HC/7116/7116lC/7116HC APPlIANCe CoMMIssIo NING CHeCKlIsT    3 CoMMIssIoNING 24 UseR INsTRUCTIoNs         4 MAINTeNANCe & seRVICING 25 General Points 4 Using the Appliance for the first time 5 Annual Service 25 Recommended Fuels 5 Removal of Log Guard 26 Lighting the appliance 6 Removal of Fire Brick 26 Running the appliance 7 Removal of Baffle 26 
                    
                    ページ3に含まれる内容の要旨 
                    
                        APPlIANCe CoMMIssIoNING CHeCKlIsT To assist us in any guarantee claim please complete the following information:- dealer appliance was purchased from Name: ................................................................................................................................................................. Address: ...............................................................................................................................................................  ............
                    
                    ページ4に含まれる内容の要旨 
                    
                        UseR INsTRUCTIoNs 1. GeNeRAl PoINTs 1.1 Before use of this appliance please read these  instructions fully.    1.2 All local regulations, including those referring to national  and european standards need to be complied with when  installing the appliance. 1.3 Only use for domestic heating in accordance with these  operating instructions.  Data Plate 1.4 You must burn only approved fuels. Do not use with liquid  fuels or as an incinerator. PR7540 1.5 Appliance surfaces become very hot when in us
                    
                    ページ5に含まれる内容の要旨 
                    
                        UseR INsTRUCTIoNs WARNING  Properly installed, operated and maintained this  appliance will not emit fumes into the room.    Occasional fumes from de-ashing and refuelling may occur.     Persistent fume emission is potentially dangerous and  must not be tolerated.   If fume emission does persist: 	 •	 Open	 doors	 and	 windows	 to	 ventilate	 the	 room 	 •Allow	 fire	 to	 burn	 out	 or	 safely	 dispose	 of	 fuel	 from	 the	 appliance 	 •	 Check	 for	 chimney	 blockage	 and	 clean	 if	 required  
                    
                    ページ6に含まれる内容の要旨 
                    
                        UseR INsTRUCTIoNs  Poor quality timber:  — Causes low combustion efficiency 4. lIGHTING THe APPlIANCe  — Produces harmful condensation 4.1 For best results:  —  Reduces effectiveness of the airwash and life of the    appliance  	 •	 S e t 	 a i r 	 c o n t r o l s , 	 S e e 	 D i a g r a m 	 6  do not burn construction timber, painted, impregnated  / treated wood, manufactured board products or pallet  wood. 3.2 solid fuel:  	 •	 Burn	 only	 anthracite	 or	 manufactured	 briquette	 smokeless	 fu
                    
                    ページ7に含まれる内容の要旨 
                    
                        UseR INsTRUCTIoNs 5.2 Burning solid fuel:  To burn solid fuel efficiently in a wood version the multi- fuel kit should be fitted.  Multi-fuel kit part numbers: Appliance Part No. Stockton 5 (all) 7108 Stockton 6 (all) 7117 Stockton 7 7109 Stockton 8 7111 PR8004 Stockton 8 Slimline 7111SL 	 •	 Close	 the	 door	 if	 desired.  Only for use with recommended fuels, see Installation    	 •	 Use	 a	 sparkguard	 if	 running	 with	 the	 doors	 open section for full fitting details. 	 •	 S e t 	 a i r 	 c
                    
                    ページ8に含まれる内容の要旨 
                    
                        UseR INsTRUCTIoNs  1) To safely remove the smoke, gases and fumes from the  5.5 When in use, burning the appliance at high output for a  house. short period also reduces tars and creosote.  2) To provide a sufficient amount of draught (suction) in the  5.6 You must burn only anthracite or smokeless fuels  appliance ensuring the fire keeps burning. suitable for use in closed appliances.  Draught is caused by the rising hot air in the chimney when  the appliance is lit. 5.7 do not burn bituminous 
                    
                    ページ9に含まれる内容の要旨 
                    
                        UseR INsTRUCTIoNs  do not re-light the appliance until the problem is solved. 8. oVeR NIGHT BURNING 7. AsH ReMoVAl 8.1 It is possible to get the appliance to burn over night.  In order to do this:   7.1 All Fuels when Multi-fuel kit is fitted:  •	 De-ash	 prior	 to	 final	 refuelling 	 •	 Riddle,	 See	 Diagram	 11  •	 Set	 air	 controls	 to	 low	 combustion	 settings  This will blacken the glass over night but it will clear when  operated at high output for a short period.  •	 Use	 smokeless	 fu
                    
                    ページ10に含まれる内容の要旨 
                    
                        UseR INsTRUCTIoNs 13.3 Ensure adequate access to cleaning doors where it is not  11. GeNeRAl CleANING possible to sweep through the chimney. 11.1 Allow appliance to cool thoroughly to avoid risk of burns: 13.4 If the appliance is believe to have previously served an  	 •	 Clean	 regularly,	 according	 to	 the	 level	 of	 use open fire the chimney must be swept a second time within  	 •	 Give	 attention	 to	 the	 baffle	 system,	 flue	 ways	 and	 a month of regular use after installation. removin
                    
                    ページ11に含まれる内容の要旨 
                    
                        UseR INsTRUCTIoNs 	 •	 Glass	 blackening 15. seAsoNAl Use 	 •	 Thick,	 brown	 and	 sticky	 tar	 oozes	 from	 the	 pipe	 joints 15.1 Clean and service the appliance if it is not used during the   This is caused by burning damp wood and burning your  warmer periods of the year as detailed in the Maintenance  appliance at too low a temperature;  and Servicing section 	 •	 Use	 wel l	 season ed	 wood	 and	 operate	 the	 appliance	 in	 the	 ideal temperature range 15.2 Set the air controls 50% open t
                    
                    ページ12に含まれる内容の要旨 
                    
                        TeCHNICAl sPeCIFICATIoN sToCKToN Model Stockton 3 - 7118 Stockton 4 - 7101/7102 Stockton 5 - 7119/7160/7108/7127/Stockton 5ML - 7130 Stockton 6 - 7100/7162/Stockton 6HL - 7117 Stockton 7 - 7120/7163 Stockton 8 - 7103/7104/7105/7113/7113LC/7113HC/7114/7128 Stockton 11 - 7106/7106LC/7106HC/7116/7116LC/7116HC Wood Nominal Heat Output kW 3.75 4.0 4.9 4.9 6.0 6.0 7.0 8.0 7.0 11.0 kW Solid Fuel 3.75 4.0 4.9 4.9 6.0 6.0 7.0 8.6 7.0 N/A mm Wg Flue Draught at Nominal Heat Output All Fuels 1.25 1.25 1.25 
                    
                    ページ13に含まれる内容の要旨 
                    
                        TeCHNICAl sPeCIFICATIoN sToCKToN dIMeNsIoN s 1. sTANdARd FeATURes B •	 Primary	 air	 (under	 grate	 air	 for	 full	 multi-fuel	 use) C •	 Airwash	 (for	 wood	 burning	 /	 clean	 glass) •	 Preset	 secondary	 air	 control	 (to	 ensure	 complete	 burning	 of	 H (dia) flue gases) •	 Riddling	 grate	 system	 for	 clean	 de-ashing	 (when	 fitted	 with	 D multi-fuel kit) •	 Removable	 door	 handle	 tool •	 Top	 or	 rear	 flue	 exit	 option A A A 2. PACKING lIsT E •	 User	 Instructions G •	 Installer	 I
                    
                    ページ14に含まれる内容の要旨 
                    
                        TeCHNICAl sPeCIFICATIoN sToCKToN dIMeNsIoN s description Model A B C d e F G H (dia)  stockton 3 7118 510 389 291 90 405 338 96 125  7101  stockton 4 572 389 291 90 465 338 112 125 7102 7119  stockton 5 544 481 294 90 436 335 120 125 7127 7160  stockton 5 lC 684 503 294 90 436 335 120 125 7161  stockton 5Ml 7130 600 481 294 90 493 294 175 125 7100  stockton 6 609 456 339 90 501 380 120 125 7162  stockton 6 Hl 7117 1020 456 338 90 913 380 263 125 7120  stockton 7 580 536 341 105 455 385 121 150 7
                    
                    ページ15に含まれる内容の要旨 
                    
                        sITe ReQUIReMeNTs 1.5 You must sweep and inspect the flue when the appliance is  1. FlUe oR CHIMNeY installed. 1.6 You must check the flue draught with all windows and  1.1 The flue or chimney system must be in good condition. doors closed and any extraction fans in this or adjoining   It must be inspected by a competent person and passed for  rooms running at maximum speed. (See next section for  use with the appliance before installation additional ventilation requirements)  Products of combus
                    
                    ページ16に含まれる内容の要旨 
                    
                        sITe ReQUIReMeNTs 1. FlUe oUTleT PosITIoNs Horizontal  Terminal Measurement Flue 150mm  Vertical  max Measurement Adjacent  Building Insulation The vertical measurement is the lowest from either the  point of discharge or 150mm above insulation. Position on Roof Minimum Clearances IMPORTANT: Seek specialist  On ridge or within 600mm 600mm above ridge A advice if installing in a dwelling  with a thatched roof Elsewhere on roof 2300mm horizontally from roof surface and: B a) 1000mm above highest p
                    
                    ページ17に含まれる内容の要旨 
                    
                        sITe ReQUIReMeNTs WAlls NeXT To A HeARTH Thickness W Solid, non-combustible  material e.g. masonry or  concrete H 150mm minimum C 150mm C minimum PR7204 Position of Appliance & Hearth in relation to walls Requirement for the walls distance of hearth from wall distance of Appliance to wall Min thickness of Wall Min height of wall  'C' 'W' 'H' 0mm 0mm - 50mm 200mm Height of appliance + 300mm Or 1200mm from the hearth (take largest  0mm 51mm - 300mm 75mm dimension) 0 - 150mm 150mm + 75mm 1200mm 150
                    
                    ページ18に含まれる内容の要旨 
                    
                        PRe-INsTAllATIoN CHeCKs 1. FlUe Model Stockton 3 - 7118 Stockton 4 - 7101/7102 Stockton 5 - 7119/7160/7161/7127/Stockton 5ML - 7130 Stockton 6 - 7100/7162/Stockton 6HL - 7117 Stockton 7 - 7120/7163 Stockton 8 - 7103/7104/7105/7113/7113LC/7113HC/7114/7128 Stockton 11 - 7106/7106LC/7106HC/7116/7116LC/7116HC Without Liner System Flue/Chimney  mm 150 150 150 150 150 150 150 180 Round (diameter) Size inch 6 6 6 6 6 6 6 7 Without Liner System (square)  mm 135 135 135 135 135 135 135 165 Minimum Dimens
                    
                    ページ19に含まれる内容の要旨 
                    
                        PRe-INsTAllATIoN CHeCKs 3. VeNTIlATIoN 3.1 This appliance requires ventilation to supply combustion air.  Any room containing the appliance must have a permanent  2  air vent opening with a total free area of at least 550mm per kW of appliance rated output above 5kW. 3.2 Increase air supply provisions where a room contains  multiple appliances. 3.3 If vents open into adjoining rooms or spaces there must be  an air vent of at least the same size direct to the outside. 3.4 Permanent air vents shou
                    
                    ページ20に含まれる内容の要旨 
                    
                        INsTAllATIoN INsTRUCTIoNs  leGAl ReQUIReMeNTs Before installation of this product please read these  instructions fully. It is very important to understand the requirements of the national  Building Regulations* and standards**, along with any local  regulations and working practices that may apply. Should any  conflict occur between these instructions and these regulations  Top Rear then the regulations must apply. PR8007 PR8008 Your local Building Control Office can advise regarding the 	 •	 F