SHOULD ATTEMPT INSTALLATION!                                                                                                                                                                                                                                                                                                                                         
                    
                    ページ2に含まれる内容の要旨 
                    
                        The operator is responsible for proper and safe use  INTRODUCTION of the equipment. The manufacturer strongly recom- Thank you for purchasing the PowerMaster Assembly  mends that the operator read this Owner's Manual  by Generac Power Systems, Inc. and thoroughly understand all instructions before  Every effort was expended to make sure that the  using this equipment. The manufacturer also strong- information and instructions in this manual were  ly recommends instructing other users to properly
                    
                    ページ3に含まれる内容の要旨 
                    
                        Table of Contents PowerMaster Technical Manual Introduction ........................Inside Front Cover Section 3 – Operation ......................................7  Read This Manual Thoroughly ........................ IFC 3.1 Testing the PowerMaster Operation ................ 7  Operation and Maintenance ............................ IFC  How to Obtain Service ..................................... IFC Section 4 – Electrical Data ..............................8  Authorized Dealer Locator Number .
                    
                    ページ4に含まれる内容の要旨 
                    
                        IMPORTANT SAFETY INSTRUCTIONS PowerMaster Technical Manual   SAVE THESE INSTRUCTIONS – This manual contains important instructions that should be  followed during installation and maintenance of the generator and batteries. The manufac-   turer suggests that these rules for safe operation be copied and posted in potential hazard  areas. Safety should be stressed to all operators and potential operators of this equipment. � WARNING:    GENERAL HAZARDS    � The engine exhaust from this produ
                    
                    ページ5に含まれる内容の要旨 
                    
                        IMPORTANT SAFETY INSTRUCTIONS PowerMaster Technical Manual  ELECTRICAL HAZARDS  FIRE HAZARDS      � All generators covered by this manual produce  � For fire safety, the generator(s) must be installed  dangerous electrical voltages and can cause fatal  and maintained properly. Installation always must  electrical shock. Utility power delivers extremely  comply with applicable codes, standards, laws  high and dangerous voltages to the transfer switch  and regulations. Adhere strictly to local
                    
                    ページ6に含まれる内容の要旨 
                    
                        Section 1 — General Information PowerMaster Technical Manual 1.1 INTRODUCTION 1.4 ENCLOSURE DETAILS This manual has been prepared especially for the The enclosure is a National Electrical Manufacturer’s  purpose of familiarizing personnel with the design, Association (NEMA) 1 type. NEMA 1 type enclosures  application, installation, and operation of the appli- are suitable only for indoor mounting. cable equipment. Read the manual carefully and  comply with all instructions. This will help to pre
                    
                    ページ7に含まれる内容の要旨 
                    
                        Section 2 — Installation PowerMaster Technical Manual 2.3  CONNECTING THE SOURCE 2.4  CONNECTING THE CONTROL  VOLTAGE(S) AND LOAD(S) CIRCUITS The source voltage(s) are taken from the load center The PowerMaster Load center is controlled by a  and connected to the PowerMaster assembly as fol- 24Vac control voltage. The most common application  lows: is to use the 24Vac control signal from a furnace or  central air conditioning system, but any 24Vac con- � Refer to the system diagram and the wirin
                    
                    ページ8に含まれる内容の要旨 
                    
                        Section 2 — Installation PowerMaster Technical Manual 2.5  INSTALLING THE AUXILIARY 2.6  CONNECTING THE AUXILIARY  SWITCHES TO THE TRANSFER SWITCHES The auxiliary switches need to be connected to the  SWITCH PowerMaster assembly using a minimum of 18AWG  The included auxiliary switches need to be added to  wire as follows: Refer to figure 2. the transfer switch to provide switch position sens- ing to the PowerMaster assembly. This allows the   2.6.1 GENERATOR SIDE AUXILIARY SWITCH PowerMaster as
                    
                    ページ9に含まれる内容の要旨 
                    
                        Section 3 — Operation PowerMaster Technical Manual Figure 3 — System Diagram 3.1  TESTING THE POWERMASTER  OPERATION p The PowerMaster assembly can be functionally tested OWERMaster using the following steps: K1 Load Center Note: the following steps will reference a central air  Customer conditioner being used as the high demand appliance  Selected Load #1 controlling the PowerMaster assembly. 1. Ensure the Utility supply is available and the  transfer switch is in the utility position. K2 � Ens
                    
                    ページ10に含まれる内容の要旨 
                    
                        Section 4 — Electrical Data Electrical Schematic - Drawing No. 0F8146-A  8  8                                                                                                                                                                                                                                                                                                                                                                                                                                       
                    
                    ページ11に含まれる内容の要旨 
                    
                        Section 4 — Electrical Data Electrical Schematic - Drawing No. 0F8146-A     99                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    ページ12に含まれる内容の要旨 
                    
                        Section 5 — Exloded Views & Parts Lists Assembly - Drawing No. 0F9110-A  10                                                                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    ページ13に含まれる内容の要旨 
                    
                        Section 5 — Exloded Views & Parts Lists Assembly - Drawing No. 0F9110-A ITEM PART NO. QTY. DESCRIPTION  1 0F9080 1 LOAD DISCONNECT ENCLOSURE  2 0F9081 1 LOAD DISCONNECT ENCLOSURE COVER  3 0C3211T 2 RELAY 40A @ 300VAC DPDT  4 0C3211U 2 RELAY DPDT 24VAC 5A 8 PIN  5* 0C3211G 2 SOCKET RELAY 8 PIN  6* 0F9072 1 BLOCK TERM 10MM 8 POS MOLEX  7 074908 4 SCREW HHTT M5-0.8 X 10BP  8 0C2265 4 SCREW PHTT M5-0.7 X 12 ZYC  9 0C2695 4 SCREW PHTT M4-0.7 X 20 ZYC  10 0C2323 3 SCREW PHTT #6-32 X 5/8 ZYC  11 0F9151
                    
                    ページ14に含まれる内容の要旨 
                    
                        Section 6 — Notes  12                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               
                    
                    ページ15に含まれる内容の要旨 
                    
                        Section 6 — Notes   13                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    ページ16に含まれる内容の要旨 
                    
                        Section 7 — Warranty PowerMaster Technical Manual GENERAC POWER SYSTEMS STANDARD TWO-YEAR LIMITED WARRANTY FOR GENERAC TRANSFER SWITCH SYSTEMS NOTE: ALL UNITS MUST HAVE A START-UP INSPECTION PERFORMED BY AN AUTHORIZED GENERAC DEALER. For a period of two (2) years or two thousand (2,000) hours of operation from the date of sale, which ever occurs first, Generac Power Systems, Inc. will, at its  option, repair or replace any part(s) which, upon examination, inspection, and testing by Generac Power