ページ1に含まれる内容の要旨 
                    
                         
 
 
 
 
Page 
Table of Contents 
 
OWNER’S AND 
 
 
1 Safety Guidelines 2 
OPERATOR’S MANUAL 2 Specifications 5 
2.1  Specification Matrix 5 
 
2.2  Ambient Condition 6 
6 
3 Use 
Sound Proof  
4 Parts 6 
 
4.1  External View 6 
Diesel Engine Generator 
7 
4.2  Control Panel 
8 
5 Equipment 
5.1  Monitor Display 8 
11 
5.2  Gauges 
14 
5.3  Fuel Line Changeover Valve 
DG150MI 
15 
6 Transportation and installation 
15 
6.1  Transportation 
16 
6.2  Installation 
DG250MI 
17 
7 Connection 
17 
                    
                    ページ2に含まれる内容の要旨 
                    
                        Introduction    Thank you for purchasing Shindaiwa Sound Proof Diesel Engine Generator.     This user manual was created to ensure the safe operation of this equipment.  Therefore, the manufacturer of  this equipment strongly recommends that the user follow the instructions herein, to avoid unnecessary  accidents and repairs.   Please operate this equipment after thoroughly reviewing and understanding the contents of this manual.   Please attach this manual, if the equipment will be sub-lease
                    
                    ページ3に含まれる内容の要旨 
                    
                        1    Safety Guidelines  ! Danger :Suffocation from exhaust fume   Exhaust fume from the engine contains many elements harmful to human.  Do not operate this  equipment in poorly ventilated area, such as inside a room or in a tunnel    ! Danger :Electrical Shock   Do not touch the output terminals during operation.   Be sure to place covers over the output terminals and fasten with fasteners.   Do not insert metal objects (such as pin or wire) into plug-in receptacles.   Do not touch wiring 
                    
                    ページ4に含まれる内容の要旨 
                    
                        Caution ! :Injuries to eyes and skin   Battery fluid contains diluted sulfuric acid.  Avoid contact with eyes, skin or on clothing.  If the acid comes  in contact, especially with eyes, flush with a lot of water, and contact your physician immediately.  Caution ! :Fire   This equipment uses Diesel Oil as a fuel.  When refueling, always stop the engine, and keep away from  fire.  Moreover, always wait until the engine cools down before refueling.   Always wipe any drip of Diesel fuel or Lubric
                    
                    ページ5に含まれる内容の要旨 
                    
                        Location of Warning labels    When the warning labels become unreadable or damaged, place new labels on the appropriate location, as  specified in the following figure.  When ordering the label, use following part numbers.    1 Safety guidelines Part Number  19402-00188  2 Suffocation from exhaust fume Part Number  19402-00161  3 Electrical Shock Part Number  19402-00163  4 Injuries Part Number  19402-00167  5 Injuries Part Number  19402-00162  6 Burns Part Number  19402-00165  7 Burns Part Numb
                    
                    ページ6に含まれる内容の要旨 
                    
                        2    Specifications  2.1    Specification Matrix    Name of Generator DG150MI DG250MI  Blushless, Rotating Field, 3-Phase, 4-Pole,  Type Unit  Synchronous  AC Generator  kVA 12.5 15 20 25  Rated Output  kW 10 12 16 20  Rated Voltage (or the below) V 200 220 200 220  Rated Current (or the below) A 36.1 39.4 57.7 65.6  Rated Voltage V 400 440 400 440    Rated Current A 18 19.7 28.8 32.8  Alternator  Frequency Hz 50 60 50 60  -1 Rated speed min 1500 1800 1500 1800  Winding - 3-phase, 4-wire, Star w
                    
                    ページ7に含まれる内容の要旨 
                    
                          2.2    Ambient Condition                 Use the equipment under the following ambient condition. The other condition may cause                  trouble, insufficient output power or deterioration of durability.                 ■ Ambient Temperature: -15ºC ~ 40ºC                 ■ Humidity                    : less than 80%                 ■ Altitude                      : less than 300m       3   Use        Power source for construction –use equipment, such as submersible pump   Power sourc
                    
                    ページ8に含まれる内容の要旨 
                    
                         4.2   Control panel    [DG150MI]                                                          [DG250MI]                              No. Name No. Name    1 3-Phase Circuit Breaker 11 Monitor Indication Lamp   2 Pilot Lamp 12 Water Temperature Gauge   Tachometer    3 Single-Phase Circuit Breaker 13  (Hour Meter incorporated)    4 Earth Leakage Relay 14 Oil Pressure Gauge    5 Voltage Meter 15 Preheat Lamp    6 Amp. Meter 16 Emergency Stop Button    7 Frequency Meter 17 Throttle Handle  8 Panel Light
                    
                    ページ9に含まれる内容の要旨 
                    
                        5   Equipment   5.1   Monitor Display                    [DG250MI]                                                                      [DG150MI]  + ++ + - - -- + ++ + -- -- WATER TEMP OIL PRESS CHARGE AIR FILTER BATTERY LOW LEVEL FUEL LEVEL                                 DG250MI is equipped with monitoring function for water/coolant temperature, oil pressure, battery charge, air  filter flow, battery fluid level, and fuel level. DG150MI is equipped with monitoring function for water/coolant  t
                    
                    ページ10に含まれる内容の要旨 
                    
                        When the water temperature reaches 110 degrees Celsius during operation,   the water temperature-monitoring lamp will flash, and the automatic shutoff will be engaged.    When this occurs, check the Coolant reservoir tank, and replenish if needed   (refer to 8-2 Checking coolant / water level).    If the water level is normal, check for loose fan belt or possible water leak in the cooling system,   after the engine is cooled down.       If the water level is too low, the sensor cannot d
                    
                    ページ11に含まれる内容の要旨 
                    
                        5.1.3   Battery Charge Monitoring Lamp (charge lamp)    When the battery is unable to be charged during operation, the battery charge-monitoring lamp   will flash.    Check the belt for damages or cut, and replace if needed.       For changing the belt, refer to the User Manual for Engine.   Battery Charge Monitor cannot detect the degradation of battery life nor the battery fluid  level (refer to 8-6 Checking Battery)    5.1.4   Air Filter Monitoring Lamp (clogged filter element) [DG
                    
                    ページ12に含まれる内容の要旨 
                    
                        When the battery fluid level is low, Battery Fluid Monitoring Lamp will flash.   If the lamp is flashing, quickly add some distilled water. (refer to 8.6 Checking Battery)        5.1.6   Fluid Level Monitoring Lamp [DG250MI only]    Caution !  : Fire   This equipment uses Diesel fuel as a fuel.  When refueling, always stop the engine, and  keep away from fire.  Moreover, always wait until the engine cools down before  refueling.   Always wipe any drip of Diesel fuel or oil.  Do not use this eq
                    
                    ページ13に含まれる内容の要旨 
                    
                          5.2.3   Water Temperature Gauge  [DG250MI only]  Water Temperature Gauge displays the temperature of engine coolant.  Normal temperature  may vary depending on the environment, but it should be between 75 to 90 degree Celsius.     If the temperature exceeds normal value, disconnect the load, idle the engine   -1 at 1000min , and wait until the reading falls to the normal temperature range.    5.2.4   Oil Pressure Gauge [DG250MI only]  Oil Pressure Gauge displays the pressure of engine
                    
                    ページ14に含まれる内容の要旨 
                    
                        2.2.6.2   Pilot Lamp [DG250MI only]  Pilot Lamp indicates whether or not the generator is generating electricity,  when the engine is driving.      5.2.7   Switch  5.2.7.1   Starter Switch  ① ①① ① STOP  When the switch is set to this position, all power will be off. The switch  must be   set to this position to remove the key.  ② ②② ② RUN / PREHEAT  The switch must be set to this position during operation.  This position is also  used during cold season, to preheat Glow Plug.    Do not 
                    
                    ページ15に含まれる内容の要旨 
                    
                        5.2.8   Voltage Regulator and Throttle Handle  5.2.8.1   Voltage Regulator  The dial adjusts output voltage. By turning the dial clockwise, an operator can increase  voltage.  By turning the dial counter-clockwise, an operator can decrease voltage.      5.2.8.2   Throttle Handle  This handle controls the engine revolution.  By turning the throttle clockwise,  engine speed slows down; turning the handle counter-clockwise increases the  speed.  The lock of the handle at the required position (spee
                    
                    ページ16に含まれる内容の要旨 
                    
                        5.3.1   Using fuel from built-in fuel tank    The lever for 3-way valve is set to A when the equipment is  shipped.  In addition, both the external fuel intake and the  external fuel return are safeguarded with PT-3/8 plugs.  Do not  remove the plugs, when using the built-in fuel tank.                                                                      Always set the lever for 3-way valve back to A position and  cover theexternal fuel intake and return port with the supplied  plugs, af
                    
                    ページ17に含まれる内容の要旨 
                    
                        6.1.2   Transportation  When transporting this equipment, make sure that the equipment is secured properly with ropes tied   to the Side Rope Through.                  Always use extreme care when loading, unloading, and transporting the equipment.   Failure to do so may result in damages and malfunction of the equipment.    6.2   Installation    ! Danger :Suffocation from exhaust fume   Exhaust fume from the engine contains many elements harmful to human.  Do not operate this  equipme
                    
                    ページ18に含まれる内容の要旨 
                    
                         Do not block the airflow from radiator vent or muffler exhaust. It may result in reduced engine  performance, overheating, or damage to the electrical parts.   Operating in dusty area or salty air (by the ocean), or any other particulate environment may result in  clogged radiator, which may cause overheating, other malfunctions and insulation deterioration.   Use extreme care, frequent checks and maintenance.      7   Connection  7.1   Selecting Cable  Select the cable with proper gauge, bas
                    
                    ページ19に含まれる内容の要旨 
                    
                                 ■ Selection of cable               (Example) 220V and Voltage Drop 11V  2               3-Phase 3-Wire Cap Tire Cable, Single Core                                                                (Unit: mm )         Length  50m or 75m 100m 125m 150m 200m    below  Current   20A 3.5 5.5 8 8 14 14  40A 8 14 14 14 22 22  60A 14 14 22 22 30 38  80A 14 22 22 30 38 50                      (Example) 100V and Voltage Drop 5V                1-Phase 2-Wire Cap Tire Cable, Single Core  2            
                    
                    ページ20に含まれる内容の要旨 
                    
                        7.2.1   Load Connection Terminal Plate (3-Phase / 1-phase)  ■ For 3-Phase Load  Terminal Voltage : 200V / 220V (or 400V / 440V) at 50Hz / 60Hz       R     S     T     O            ◯    ◯    ◯  ◯                     Load    ■  For 1-Phase Load (1)                    Terminal Voltage : 115V / 127V (or 230V / 254V) at 50Hz / 60Hz          R   S      T   O               ◯    ◯    ◯    ◯                                          Load    Load    Load    ■ For 1-Phase Load (2)  Terminal Voltage: 200V/22