ページ1に含まれる内容の要旨 
                    
                        OPERATION AND PARTS MANUAL
GLOBUG SERIES
MODELS:
 GBW/GBWE (Pentapod With Lamp)
GBS (Offset Pole With Lamp
GBP (Lamp Only)
GBHM (Hitch Mount Accessory)
GBMP (Mounting Plate)
ORIGINAL COPY
Revision #0 (07/23/09)
To fi nd the latest revision of this 
publication, visit our website at: 
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.                                                                                                                                                
                    
                    ページ2に含まれる内容の要旨 
                    
                        PROPOSITION 65 WARNING PAGE 2 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ページ3に含まれる内容の要旨 
                    
                        TABLE OF CONTENTS Suggested Spare Parts ......................................... 35 GBW/GBWE/GBS/GBP/ Component Drawings GBHM/GBMP Nameplates And Decals (GBW/GBWE) ........... 36-37 Lighting System Nameplates And Decals (GBS) ........................ 38-39 Proposition 65 Warning ........................................... 2 Balloon And Lamp Assy (GBW/GBWE/GBS) ... 40-41 Table Of Contents .................................................... 3 Mast Assy (GBW/GBWE) ................................
                    
                    ページ4に含まれる内容の要旨 
                    
                        PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Effective:  st January 1 , 2006 Best Deal! Order via Internet (Dealers Only): If you have an MQ Account, to obtain a Username  Order parts on-line using Multiquip’s SmartEquip website! and Password, E-mail us at: parts@multiquip. com.  ■ View Parts Diagrams To obtain an MQ Account, contact your  ■ Order Parts District Sales Manager for more information.  ■ Print Specifi cation Information Use the inter
                    
                    ページ5に含まれる内容の要旨 
                    
                        SAFETY INFORMATION Do not operate or service the equipment before reading Potential hazards associated with the operation of this the entire manual. Safety precautions should be followed equipment will be referenced with hazard symbols which at all times when operating this equipment. may appear throughout this manual in conjunction with Failure to read and understand the safety safety messages. messages and operating instructions could  result in injury to yourself and others. SAFETY MESSAGES T
                    
                    ページ6に含まれる内容の要旨 
                    
                        SAFETY INFORMATION GENERAL SAFETY   NOTICE   CAUTION  This equipment should only be operated by trained and qualifi ed personnel 18 years of age and older.  NEVER operate this equipment without proper protective  clothing, shatterproof glasses, respiratory protection,   Whenever necessary, replace nameplate, operation and hearing protection, steel-toed boots and other protective safety decals when they become diffi cult read. devices required by the job or city and state regulations.  Manufact
                    
                    ページ7に含まれる内容の要旨 
                    
                        SAFETY INFORMATION LIGHTING SYSTEM SAFETY LAMP SAFETY   DANGER  WARNING  NEVER use lighting system in rain, snow or  NEVER attempt to replace lamp with the power on. areas of high humidity that could generate Always unplug the power cord from the generator or electrical storms. power source when changing the lamp.   WARNING  ALWAYS allow a suffi cient amount of time for the lamp to cool before changing. The possibility exists of severe burns.  NEVER disconnect any emergency or safety devices.
                    
                    ページ8に含まれる内容の要旨 
                    
                        SAFETY INFORMATION BALLOON SAFETY ELECTRICAL SAFETY   WARNING  DANGER  To prevent serious burns, NEVER touch  Lighting system is equipped with a ground pin on the or unzip the balloon envelope when the power plug. For your protection, ALWAYS complete the lamp is on. grounding path. NEVER insert the AC power plug into a 2-prong receptacle to operate lighting system.   CAUTION  When applying power to the lighting system, ALWAYS   ALWAYS keep the balloon away from sharp objects and  connect the 
                    
                    ページ9に含まれる内容の要旨 
                    
                        SAFETY INFORMATION LOADING AND UNLOADING Cart Type - No Lifi ting Hook If lighting system is not equipped with a transport lifting Cart Type - With Lifi ting Hook hook and the mast is removable, refer to the following If lighting system is equipped with a transport lifting hook,  safety information. refer to the following safety information.  Before lifting, make sure that the mast and lamp are   CAUTION removed as described in the manual.  Before lifting, make sure that lighting system parts ar
                    
                    ページ10に含まれる内容の要旨 
                    
                        SPECIFICATIONS Table 1. Specifi cations Model GBW/GBWE/GBS/GBP Input Voltage 120 VAC Max. Current 9.3 A @ 120 V Frequency 50-60 Hz Single-Phase Appropriate Generator 1700 Watts Lamp Lamp Type 1,000 Watt Metal Halide Total  Luminous Flux 107,000 lm Standard Balloon Diameter 47.2 in (1200 mm) Light Coverage (360°) 90 ft (27.4 meters) Lamp Surface Temperature (Longitudinal) 476.6° F (247° C) max Lamp Surface Temperature (Transversal) 417.2° F (214° C) max Dimensions (L x W x H) 8.7x 8.7 x 40 in Stor
                    
                    ページ11に含まれる内容の要旨 
                    
                        DIMENSIONS (GBW/GBWE) D B A C E Figure 1. GBW/GBWE Dimensions Table 2. GBW Dimensions Reference Letter Description Dimension inches (mm) A (GBW) Total Max. Height (with Standard Balloon) 158.3 (4,020) A (GBWE) Total Max. Height (with Standard Balloon) 193.3 (4,910) B Standard Balloon Height 28.3 (720) C Mast Height (without Balloon) 130 (3,302) D Standard Balloon Diameter 47.2 (1,200) E Mast Height (Stowed) 28.3 (720) GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAG
                    
                    ページ12に含まれる内容の要旨 
                    
                        DIMENSIONS (GBS) B F D C GB36 BALLOON SHOWN G OFFSET POLE I E H J A Table 3. GBS Dimensions STRAIGHT POLE Reference Letter Dimension inches (mm) A 44.68 (1,135) B 35.43 (900) K C 33.46 (850) D 38.38 (975) E 85.62 (2,175) F 26.88 (683) G 16.73 (425) H 39.37 (1,000) I 8.66 (220) J 7.87 (200) BALLOON K 28.34 (720) ASSEMBLY Figure 2. GBS Dimensions PAGE 12 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)                                                                       
                    
                    ページ13に含まれる内容の要旨 
                    
                        DIMENSIONS (GBP) A B Figure 3. GBP Dimensions Table 4. GBP Dimensions Reference Letter Dimension inches (mm) A 35.43 (900) B 33.46 (850) GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 13                                                                                                                                                                                                                                                                                         
                    
                    ページ14に含まれる内容の要旨 
                    
                        FOOTCANDLE PLOT .25 .5 1 2 5 10 VALUES LISTED AS FOOTCANDLES SCALE: 1 GRID = 50 FT. (15.24 METERS) Figure 4. Illumination Range PAGE 14 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)                                                                                                                                                                                                                                                                                                  
                    
                    ページ15に含まれる内容の要旨 
                    
                        GENERAL INFORMATION The Multiquip GloBug GBW/GBWE, GBS, GBP are The GBW/GBWE has a three-stage mast that extends to a  general- purpose, portable, glare-free lighting systems height of up to 13 feet and 2 inches. The GBW/GBWE has  intended for emergency and remote lighting needs. It is fi ve outriggers (pentapod) for great stabilization. universally adaptable to all AC power supplies and accepts  The GBS is designed to be attached to an external piece of  50/60 Hz, 100-240 V. equipment such as a 
                    
                    ページ16に含まれる内容の要旨 
                    
                        COMPONENTS GBP 1 13 2 3 12 4 19 14 20 18 11 5 17 10 9 16 15 8 7 6 GBW/GBWE 21 22 28 27 25 26 23 24 GBHM GBMP 5 GBWE/GBHM/ GBMP ONLY GBS Figure 5. GBW/GBWE/GBS/GBP Components PAGE 16 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)                                                                                                                                                                                                                                                    
                    
                    ページ17に含まれる内容の要旨 
                    
                        COMPONENTS Figure 5 shows the location of the controls and components 14. Lamp Holder — Holds lamp in place. Lamp is screwed  for the GBW Lighting System. The functions of each control into socket. is described below: 15. Balloon Connector — Connect this connector to the  1. Balloon Cover — Stores balloon when GBW is not in AC power cable connector. use. Allow a suffi cient amount of time for the lamp to  16. Lamp/Balloon Bolt — Used to tighten mast when  cool down before storing balloon. Possibi
                    
                    ページ18に含まれる内容の要旨 
                    
                        SETUP upper or lower position. Placing the lock in the upper  GBW/GBWE SETUP position will provide 1 foot (305 mm) more height. See  1. Set the GBW on a fi rm level surface where there is  Figure 8. enough space around the pentapod for the outriggers  to be deployed. LATCH 2. Remove the pentapod from the carrying case. The  pentapod outriggers are secured together with a strap.  UPPER See Figure 6. Squeeze both tabs on the buckle to  POSITION unlock strap and release pentapod outriggers. LOWER PO
                    
                    ページ19に含まれる内容の要旨 
                    
                        SETUP 4. Attach the straight pole to the clamps. Tighten locknuts  GBS SETUP on both clamps. See Figure 13. 1. Attach one of the clamps that come with the GBS to the  STRAIGHT external support pole. The clamps may be attached to  POLE vertical, horizontal, or angled pole. See Figure 11. VERTICAL EXTERNAL SUPPORT POLE CLAMPS CLAMP LOCKNUT Figure 13. Straight Pole Attachment   WARNING Always securely tighten the locknuts when assembly  CLAMP is used to prevent the lighting system from falling off 
                    
                    ページ20に含まれる内容の要旨 
                    
                        SETUP 5. Connect the power cable to the lamp cable connector.  BALLOON INSTALLATION (GBW/GBWE/GBS) See Figure 18. 1. Insert the balloon assembly into the mast. Tighten the  T-bolt securely. See Figure 15. LAMP CABLE BALLOON CONNECTOR PROTECTIVE COVER POWER CABLE CONNECTOR T-BOLT MAST Figure 15. Installing the Balloon Figure 18. Connecting the Power Cable 2. Unsnap the three buttons on the bottom of the balloon  6. Secure the power cable by hooking it to the eyelet on  cover and unzip the cover.