ページ1に含まれる内容の要旨 
                    
                         
Adam Equipment 
 
 
 
 
 
 
 
ABK, AFK Scales 
 
 
 
(P.N. 3116611364 - Revision A, December 2011) 
 
        © Adam Equipment Company 2011                                                                                                                                                                                                                                                                                                                                                                       
                    
                    ページ2に含まれる内容の要旨 
                    
                                      Easy Reference:        Model name of the scale:     Serial number of the unit:     Software revision number      (Displayed when power is first turned on):  Date of Purchase:     Name of the supplier and place:                                 © Adam Equipment Company 2011                                                                                                                                                                                                                      
                    
                    ページ3に含まれる内容の要旨 
                    
                        CONTENTS    1.0 INTRODUCTION .................................................................................................................................. 3  2.0 SPECIFICATIONS................................................................................................................................ 4  3.0 INSTALLATION .................................................................................................................................... 6  3.1 UNPACKING ....................
                    
                    ページ4に含まれる内容の要旨 
                    
                          2 | P a g e         © Adam Equipment Company 2011                                                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    ページ5に含まれる内容の要旨 
                    
                              1.0 INTRODUCTION    • The ABK/AFK scales provides an accurate, fast and versatile  general purpose weighing scales with parts counting, percent  weighing and check-weighing functions.     • The ABK/AFK has LEDs to indicate when a weight is below the  low limit, between the limits or above the high limit next to the  display.  These can work in conjunction with an audible alarm for  check weighing as well as LCD showing LO, OK and HI.    • The ABK/AFK is supplied with a RS-232 bi-directiona
                    
                    ページ6に含まれる内容の要旨 
                    
                        2.0 SPECIFICATIONS    ABK 8  ABK 16 ABK 32 ABK 60 ABK 120   Model #  ABK 16a ABK 35a ABK 70a ABK 130a ABK 260a  Maximum  8000g/16lb 16kg/35lb 32kg/70lb 60kg/130lb 120kg/260lb  Capacity  Readability 0.2g/0.0005lb 0.5g/0.001lb 1g/0.002lb 2g/0.005lb 5g/0.01lb  Resolution 1:40000 1:32000 1:32000 1:30000 1:24000  Repeatability  0.2g/0.0005lb 0.5g/0.001lb 1g/0.002lb 2g/0.005lb 5g/0.01lb  (Std Dev)  Linearity + 0.4g/0.001lb 1g/0.002lb 2g/0.004lb 4g/0.01lb 10g/0.02lb  Eccentric Loading  0.4g/0.001lb 1g/
                    
                    ページ7に含まれる内容の要旨 
                    
                            Model # AFK 75/165a AFK 150/330a AFK 300/660a AFK 600/1320a  Maximum  75kg/165lb 150kg/330lb 300kg/660lb 600kg/1320lb  Capacity  Readability 5g/0.01lb 10g/0.02lb 20g/0.05lb 50g/0.1lb  Resolution 1:15000 1:15000 1:15000 1:12000  Repeatability  5g/0.01lb 10g/0.02lb 20g/0.05lb 50g/0.1lb  (Std Dev)  Linearity + 10g/0.02lb 20g/0.04lb 40g/0.1lb 100g/0.2lb  Eccentric  Loading 10g/0.02lb 20g/0.04lb 40g/0.1lb 100g/0.3lb    Pan size  400mm x 500mm  w x d  Units of  g / Kg  / Lb  / Lb:oz  / Newtons/Oun
                    
                    ページ8に含まれる内容の要旨 
                    
                        3.0 INSTALLATION  3.1 UNPACKING   The ABK/AFK scales have already been adjusted to work with a platform and  have been configured for this application.    The platform and indicator have  been calibrated as a pair  and must be used together .   3.2 LOCATING   • The scales should not be placed in a location that  will reduce the accuracy.     • Avoid extremes of temperature. Do not place in   direct sunlight or near air conditioning vents.      • Avoid unsuitable tables. The table or floor must b
                    
                    ページ9に含まれる内容の要旨 
                    
                        3.3 SETTING UP THE SCALES    • The pillar is attached to the base using a bracket that must be  attached to the base frame first using the 4 bolts supplied.  The  pillar is secured to the bracket using 2 sets of screws.  The cable  from the base to the indicator module is run through the tube and  taken out through the support at the top.  Excess cable can be  stored within the tube.      • The ABK/AFK Series comes with a stainless steel platform  packed separately. Place the platform in the bas
                    
                    ページ10に含まれる内容の要旨 
                    
                          4.0 KEY DESCRIPTIONS              [>Z/T<]    If near zero, Sets the zero point for all subsequent   weighing. The display shows zero.    Tares the scale. Stores the weight currently on the  scale as tare value, subtracts the tare value from the  gross weight and shows the results    A secondary function,         is of “Enter” key used when  setting up the value for the Parameters.    [Pcs/]      Selects parts counting. Used to set the sample  quantities while parts counting.    A secondary fu
                    
                    ページ11に含まれる内容の要旨 
                    
                          [Func/C]  Selects the Functions of the scale. If the scale is   weighing, it will select parts counting. If it is not in  weighing mode, it will return the user to weighing.      A secondary function (C) is to act as a clear key when  setting values for Parameters.    [Print/M+/Esc]  Sends the results to a PC or a Printer using the RS-  232 interface. It also adds the value to the  accumulation memory if the accumulation function is  not automatic.     A secondary function (ESC) is to return t
                    
                    ページ12に含まれる内容の要旨 
                    
                        5.0 DISPLAYS    The LCD display will show a value and a unit to the right of the digits.   In addition the LED’s above the display will show when a weight is below or  above check-weighing limits.         Other symbols will show when a weight has been tared (NET) the scale is at  zero and stable, if a value has been stored in memory or when the animal  weighing function has been enabled.  A battery symbols will show the state of  charge of the internal battery. 11 | P a g e         © Adam Equipm
                    
                    ページ13に含まれる内容の要旨 
                    
                          6.0 OPERATION  6.1 ZEROING THE DISPLAY    • You can press the [Z/T] key at any time to set the zero point. This  will usually be necessary when the platform is empty. When the  zero point is obtained the display will show an indicator for zero.          • The scale has an automatic re-zeroing function to account for  minor drifting or accumulation of material on the platform.  However you may need to press the [Z/T] key to rezero the scale  if small amounts of weight are shown when the platfor
                    
                    ページ14に含まれる内容の要旨 
                    
                          • Press the [Z/T] key to tare the scale. The weight that was  displayed is stored as the tare value and that value is subtracted  from the display, leaving zero on the display. The “NET” indicator  will be ON. As a product is added only the net weight of the  product will be shown. The scale could be tared a second time if  another type of product was to be added to the first one. Again  only the weight that is added after taring will be displayed.      • When the container is removed a negati
                    
                    ページ15に含まれる内容の要旨 
                    
                          6.4 PARTS COUNTING    If parts counting is enabled, See section 7.4, it is possible to count parts using   a sample of the parts to determine average piece weight.      • Before starting, tare the weight of any container that may be used,  leaving the empty container on the scale. Place a known number  of samples in the container, if used.  The number should match  the options for parts counting, i.e., 10, 20, 50, 100 or 200 pieces.     • When the scale is showing weight, pressing the [Pcs/] 
                    
                    ページ16に含まれる内容の要旨 
                    
                              • Press the [Pcs/] key to return to normal weighing. Press the  [Pcs/] key again to start counting a different sample.      6.5 CHECK-WEIGHING    Check-weighing is a procedure to cause lamps to come on (and if enabled,  an alarm to sound) when the weight on the scale meets or exceeds values  stored in memory.  The memory holds the last values for a high and a low  limit when the power is turned off.  The user can set either one limit or both as  described below.      See Section 7.1 for 
                    
                    ページ17に含まれる内容の要旨 
                    
                            BOTH LIMITS SET The display will show OK F3 bEP = bP  InL .   when the weight is The beeper will sound  between the limits when the weight is  between the limits, i.e. OK    F3 bEP = bP OtL   Beeper will sound if weight  is outside the limits.    LOW LIMIT SET  The display will show LOW F3 bEP = bP  InL .   HIGH LIMIT is set to when the weight is less The beeper will be off  zero than the Low Limit.  Above when the weight is less   the Low Limit the display than the Low Limit.   will show OK
                    
                    ページ18に含まれる内容の要旨 
                    
                        NOTE: Weight must be more than 20 scale divisions for check weighing to  operate.  Below 20 scale divisions the LED’s will not light and the  beeper will not be on.      The Check-weighing function  can be set up during Weighing or Parts Counting  by entering values as Low or/and High Limits keyed in by the user. The limits are  displayed in kg (or Lb)  or pcs respectively.        Checkweighing during Parts Counting      To disable the Check-Weighing function enter zero into both limits by  pres
                    
                    ページ19に含まれる内容の要旨 
                    
                          6.6 ACCUMULATED TOTAL    • The scale can be set to accumulate manually by pressing the  [Print/M+/Esc] key or automatically when a weight is removed  from the scale.  See the Section 7.3 for details of setting the  Parameter “C3 PRM” and “C4 Aon”.  The accumulation function is  available when weighing or when counting parts.  However the  memory is cleared if the weighing units or functions are changed.       • When the weight (or count) displayed is stored in memory the  display will show “AC
                    
                    ページ20に含まれる内容の要旨 
                    
                          6.7 PERCENT WEIGHING     The scale can be set to perform percent weighing.  See Section 7.2.    The scale will use a mass on the platform as the 100% reference weight. If  the platform is empty (or the scale is tared) then the user can input a  reference weight using the keypad.      • Press [Func/C]. The first option is “FunC 1”, press the [Func/C] key  again display “FunC 2”.     • Press the [Z/T] key. “P1 PCt” will be displayed.          • Press [Z/T] again to enter percent weighing. The sc