                        INSTALLATION INSTRUCTIONS (continued) Installing Vent Assembly Installing a Vent Near a Window Ledge,  Attention: DO NOT attempt to cut vent tubes. When you order  Other Type of Projection or on Siding (vinyl, aluminum, etc.) appropriate vent kit for measured wall depth the vent tubes will  Direct vent furnaces are designed to be installed on a uniform  fit together. outside wall. When the wind comes from any angle (up, down or  1. Place provided caulking beneath the collar of the outside  from e
                    
                    ページ12に含まれる内容の要旨 
                    
                        DVC-35T STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:  If you do not follow these instructions exactly, a fire or explosion may result  causing property damage, personal injury or loss of life. A.  This appliance has a pilot which must be lighted by • If you cannot reach your gas supplier, call the fire  hand.  When lighting the pilot, follow these instructions department. exactly. C.  Use only your hand to push in or turn the gas control  B.  BEFORE LIGHTING  
                    
                    ページ13に含まれる内容の要旨 
                    
                        DVC-35IPT INTERMITTENT PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING:  If you do not follow these instructions exactly, a fire or explosion may result  causing property damage, personal injury or loss of life. A.  This appliance is equipped with an ignition de- • If you cannot reach your gas supplier, call the fire  vice which automatically lights the pilot.    department. Do not try to light the pilot by hand. C.  Use only your hand to slide the gas control knob.  Neve
                    
                    ページ14に含まれる内容の要旨 
                    
                        PILOT FLAME CHARACTERISTICS THERMOCOUPLE The correct pilot flame (Figure 12) will be blue, extending past  the thermocouple. The flame will surround the thermocouple just  below the tip. Natural gas pilots require adjusting when the inlet gas pressure is  BURNER above 5” w.c. (1.245kPa). Remove the pilot cover screw on the  SPARK� control valve (Figure 3), and turn the adjustment screw clockwise  PILOT ELECTRODE to reduce flame. Replace pilot cover screw to eliminate gas leaking  at that control va
                    
                    ページ15に含まれる内容の要旨 
                    
                        MAIN BURNER FLAME CHARACTERISTICS The correct flame will be a short, blue inner flame with a much  larger, light blue, outer flame. The burner does not have a primary  air adjustment. The flame will be correct if the factory-set pressure  and orifice opening are used. After the furnace has been operating,  the burner ports may be blocked by foreign matter carried in by  combustion air. Therefore, cleaning of the burner may be needed  for proper flame. To clean burner port disconnect the gas supply to 
                    
                    ページ16に含まれる内容の要旨 
                    
                        PRESSURE REGULA T O R ADJUSTMENT -UNDER CAP SCREW OUTLET PRESSURE T A P PILOT ADJUSTMENT - INLET PRESSURE UNDER CAP SCREW T A B GASFLOW PILOT OUTLET IGNIT OR-PILOT ASSY . WIRING T O 2 4 V THERMOST A T T O 2 4 V COMMON ON TRANSFORMER T O 24V ."HOT" ON TRANSFORMER 1 P-MODEL GAS V AL V E AND WIRING 120 V A C L2 NEUTRAL L1 "HOT" F A N MOT OR SWITCH 120 V A C 40 V A TRANSFORMER 24 V A C V AL V E CONTROL CONNECT OR LIMIT CONTROL VENT SAFETY THERMOST A T LIMIT HONEYWELL IP SMART V A L V E LADDER WIRING
                    
                    ページ17に含まれる内容の要旨 
                    
                        SERVICE AND MAINTENANCE SUGGESTIONS GENERAL: All furnaces have been fire-tested to check for proper  If Pilot Does Not Remain On After Releasing Knob:  operation. This includes, main burner flame, pilot flame, fan  1. Follow instructions and hold button down longer and  operation, fan control, limit control and automatic valve operation.  harder. If the furnace fails to function on initial installation, it is advisable  2. Determine if pilot flame extends past thermocouple; if not,  to re-check the 
                    
                    ページ18に含まれる内容の要旨 
                    
                        DVC-35IPT INTERMITTENT PILOT SEQUENCE OF OPERATION Apply 24 V A C to Appliance ST ART Thermostat Calls for Heat 5 Minute Retry Delay Flame Signal Pilot V alve Ignition OFF Detected W ait for Flame Signal to Disappear SYSTEM CHECK Internal Check OK Pilot V alve Opens TRIAL FOR Ignitor Powered IGNITION Pilot Light and lame is Pilot V alve Closes Sensed During T rial Ignition OFF For Ignition (1) 3 Second Flame Failure Recycle Delay Ignitor Off MAIN BURNER Main V alve Opens OPERA TION Main Pilot Fl
                    
                    ページ19に含まれる内容の要旨 
                    
                        DVC-35IPT INTERMITTENT PILOT SYSTEM TROUBLESHOOTING SEQUENCE IP  SYSTEM TROUBLESHOOTING SEQUENCE START End View INSET A SmartValve™ System Troubleshooting Sequence of Control 24Volt • Turn OFF Gas Supply Note: Before Troubleshooting, Become Familiar Harness Thermostat • Disconnect System Control with the Sequence of Operation Connector Harness • Set Thermostat to Call for 24 EFT Heat Volts Output 24 Volt 24 Volt CHECK 24 Hot Common Check for Proper Voltage at • Line Voltage Power Volts Control H
                    
                    ページ20に含まれる内容の要旨 
                    
                        HOW TO ORDER REPAIR PARTS Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through  the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your  equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following approp
                    
                    ページ1に含まれる内容の要旨 
                    
                        INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
FAN TYPE
DIRECT  VENT 
WALL  FURNACE
MODEL
DVC-35T-1
DVC-35IPT-1
EFFECTIVE  DATE 
JANUARY 2007
Installer: Leave this manual with the appli-
WARNING: If the information in these instruc-
ance.
tions are not followed exactly, a fire or explosion 
Consumer: Retain this manual for future refer-
may result causing property damage, personal 
ence.
injury or loss of life.
This appliance may be installed in an aftermarket, 
— Do not store or use gasoline or ot
                    
                    ページ2に含まれる内容の要旨 
                    
                        TABLE OF CONTENTS SECTION PAGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas ......................................................................................................4 Requirements for Massachusetts ..................................................................................................................5 Introduction .................
                    
                    ページ3に含まれる内容の要旨 
                    
                        IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures the appliance should be located • DO NOT put anything around the furnace that will ob- out of traffic and away from furniture and draperies. struct the flow of combustion and ventilation air. • DO keep the appliance area clear and free from combus- • Children and adults should be alerted to the hazards of  high surface temperatures and should stay away to
                    
                    ページ4に含まれる内容の要旨 
                    
                        SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday when  and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone’s safety will depend  colorless. You may not know all the following safety precau- on knowing exactly what to do. If, after reading the following  tions which can protect both you and your family from an information, you feel you still need
                    
                    ページ5に含まれる内容の要旨 
                    
                        REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 3. SIGNAGE. A metal or plastic identification plate shall be  installed in every dwelling, building or structure used in permanently mounted to the exterior of the building at a  whole or in part for residential purposes, including those minimum height of eight (8) feet above grade directly in  owned or operated by the Commonwealth and where the line with the exhaust vent terminal for the horizontally  side 
                    
                    ページ6に含まれる内容の要旨 
                    
                        INTRODUCTION Introduction Installation in Residential Garages Always consult your local Building Department regarding regulations, Gas utilization equipment in residential garages shall be installed so that  codes or ordinances which apply to the installation of a direct vent wall all burners and burner ignition devices are located not less than 18” above  furnace. the floor. Instructions to Installer Such equipment shall be located, or protected, so it is not subject to physical  1. Installer mu
                    
                    ページ7に含まれる内容の要旨 
                    
                        GAS SUPPLY Locating Gas Supply Installing a New Main Gas Cock The gas line can enter the unit either through the floor or outside  Each appliance should have its own manual gas cock. wall. The gas line opening should be made at this time. Location  A manual main gas cock should be located in the vicinity of  of the opening will be determined by the position of floor joists  the unit. Where none exists, or where its size or location is not  and the valve and union used for servicing. adequate, cont
                    
                    ページ8に含まれる内容の要旨 
                    
                        pressure of approximately 4.0” w.c. (.996kPa) for DVC-35T and  3.5” w.c.  (.871kPa) for DVC-35IPT at the valve outlet with the  inlet pressure to the valve from a minimum of 5.0” w.c. (1.245kPa)  for the purpose of input adjustment to a maximum of 7.0” w.c.   (1.743kPa). Propane gas models will have a manifold pressure  approximately 10.0” w.c. (2.49kPa) at the valve outlet with the inlet  pressure to the valve from a minimum of 11.0” w.c. (2.739kPa)  for the purpose of input adjustment to a max
                    
                    ページ9に含まれる内容の要旨 
                    
                        INSTALLATION INSTRUCTIONS  8. Drill two (2) 1/8” diameter holes in the wall and attach the  Locating Wall Opening register with two (2) 10 x 1 1/2” provided screws. The furnace is to be located on an outside wall. Locate wall studs so   9. Installation of SOK-1 is completed. that wall opening will be located between wall studs. The furnace  is 14 1/8” in width and can be recessed between standard 16” on  center wall studs. The wall opening required as shown in Figure 5  is a diameter of 7 1/2”. 
                    
                    ページ10に含まれる内容の要旨 
                    
                        Locating Electric Supply with two (2) plastic expansion anchors provided and to floor, at the  A 7/8”  diameter knockout is provided at the bottom of the left  outer casing bottom, with two (2) 10 x 1 1/2” screws provided. and right side panels. A three-prong (grounding) plug assembly is  located within the control compartment (bottom) of the furnace.  Please remove 7/8” knockout from appropriate side panel when  routing plug assembly to an electrical outlet. Unit can be hard wired  when recessed