                        DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
Patent Pending
NATURAL GAS MODELS  
(V)TC36N(-HA) SERIES 
PROPANE/LP GAS MODELS  
(V)TC36P(-HA) SERIES
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable 
vapors and liquids in the vicinity of this or any other 
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light an
                    
                    ページ2に含まれる内容の要旨 
                    
                        TALE b OF CONTENTS Safety Information ............................................... 2 Cleaning and Maintenance ................................ 31 Product Identification ........................................... 4 Troubleshooting ................................................. 33 Local Codes......................................................... 4 Replacement Parts ............................................ 37 Product Features ................................................. 5 Service
                    
                    ページ3に含まれる内容の要旨 
                    
                        SAFETy INFORMATION  WARNING: Do not allow fans  Continued to blow directly into the fireplace.  This fireplace must be installed by a qualified (cer- Avoid any drafts that alter burner  tified or licensed) service person. It has a sealed  flame patterns. gas combustion chamber that uses a coaxial pipe  (pipe within a pipe and having the same center)  venting system. It brings in fresh air for combus- Due to high temperatures, the  tion through the outer pipe and combustion gases  appliance shoul
                    
                    ページ4に含まれる内容の要旨 
                    
                        SAFETy INFORMATION PRODUCT  Continued IDENTIFICATION 2. If you smell gas Upper Louver  Flue Collar • shut off gas supply Panel Log  • do not try to light any appliance Set • do not touch any electrical switch; do not use  Nailing any phone in your building Flange • immediately call your gas supplier from a  Glass  neighbor’s phone. Follow the gas supplier's  Door instructions Assembly • if you cannot reach you gas supplier, call the  Lava  fire department. Rock 3. Never install the fireplace • i
                    
                    ページ5に含まれる内容の要旨 
                    
                        When deciding the location of your fireplace,  PRODUCT FEATURES follow these rules: These are a few facts that can help you understand  • Do not connect this fireplace venting to a chim- and enjoy your direct-vent fireplace: ney flue serving a separate solid-fuel burning  • The venting system may be routed to the out- fireplace or appliance. side of your home in several ways. It may vent  • Due to high temperatures, do not locate this  through the roof (vertical) or it may vent to an  fireplace 
                    
                    ページ6に含まれる内容の要旨 
                    
                        PRE-INSTALLATION  NOTICE: This fireplace is in- PREPARATION tended for use as supplemental  Continued heat. Use this fireplace along  with your primary heating sys- • If recessing into a wall, you can avoid extra  framing by positioning your fireplace against  tem. Do not install this fireplace  an already existing framing member. as your primary heat source.  • Do not recess termination cap into a wall or  If you have a central heating  siding. system, you may run system’s  • You may paint the 
                    
                    ページ7に含まれる内容の要旨 
                    
                        PRE-INSTALLATION  1 PREPARATION 2 Continued 3 A Wall 4 B 5 3 5 D 5 10 /8" B 19 C /8 8" 15" 19 / " C 6 3 A 4 D 35 / " E 7 F G 3 E 13 /4" Top of Louver  F 41" Opening 1 Nailing 4 G1 /4" Nailing Tabs Tabs 1 H 68 /2" Figure 5 - Framing Clearances for Corner  Installation Mantel from  Mantel Top of Louver  Ref. Depth Ref. Opening 1 14" A 16" 2 12" B 14" 3 10" C 12" 4 8" D 10" 5 6" E 8" 6 4" F 6" 7 2" G 4" Figure 6 - Clearances for Combustible  Mantels 116192-01G www.desatech.com 7                    
                    
                    ページ8に含まれる内容の要旨 
                    
                        V G G V A D E V B L LOCATION OF TERMINATION CAP N N H C B I Fixed V V Fixed Closed Openable Closed Openable F V B G V J X B B M A V K X V TERMINATION CAP X AIR SUPPLY INLET G GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or I = clearance to service regulator vent outlet [*72" (182.9 cm)   balcony [*12" (30.5 cm) minimum]  minimum] B =  clearance to window or door that may be opened J = clearance to non-mechanical air supply inlet to building 
                    
                    ページ9に含まれる内容の要旨 
                    
                        VENTING INSTALLATION   WARNING: Read all instruc- INSTRUCTIONS tions completely and thoroughly  NOTICE: Read these instruc- before attempting installation.  tions completely before at- Failure to do so could result in  serious injury, property damage  tempting installation. or loss of life.  These models are tested and approved for use  with DESA (direct-vent) pipe components and  NOTICE: Failure to follow these in- terminations. structions will void the warranty.  The venting system must termin
                    
                    ページ10に含まれる内容の要旨 
                    
                        5. Carefully determine the location where the vent  VENTING INSTALLATION  pipe assembly will penetrate the outside wall.  INSTRUCTIONS The center of the hole should line up with the  Continued center-line of the horizontal vent pipe. Mark the  3 3 wall for a 10 /4" x 10 /4" square hole. Cut and  INSTALLATION pLANNING frame the square hole in the exterior wall where  There are two basic types of direct-vent in- the vent will be terminated. If the wall being  stallation: penetrated is constructed 
                    
                    ページ11に含まれる内容の要旨 
                    
                        VENTING INSTALLATION  INSTRUCTIONS Continued Vent Cap  WARNING: Do not recess  vent termination into any wall.  This will cause a fire hazard. 6. Noncombustible Exterior Wall: Position the  1 2 horizontal vent cap in the center of the 8 / "	 round hole and attach to the exterior wall with  four wood screws provided. Before attaching  the vent cap to exterior wall, run a bead of Wood Screw non-hardening mastic (pliable sealant) around  Figure 10 - Installing Horizontal Vent Cap  the outside edges
                    
                    ページ12に含まれる内容の要旨 
                    
                        GROUND FLOOR INSTALLATION VENTING INSTALLATION  Recommended Applications: INSTRUCTIONS • Installation using cabinet surrounds Continued • Through the wall using round or square termina- Minimum Pipe  Siding Standoff  tion (up to 12" horizontal pipe) 1 4 Overlap 1 / " • NOT FOR CORNER INSTALLATION Direct-Vent  Adjustable  Pipe Screws Horizontal  Pipe 12" Max. 45° Elbow High Wind  Wall  Square  Firestop Termination Wall Firestop Maintain 1"  Minimum Air  Space Around  High Wind  Outer Pipe When  T
                    
                    ページ13に含まれる内容の要旨 
                    
                        VENTING INSTALLATION INSTRUCTIONS Continued CORNER INSTALLATION Not to Exceed  (H) Limits Recommended Applications: Square  Termination • Corner ground floor installation 90° Elbow • Ground floor installation where pipe vents horizon- tally through wall (over 12" horizontal pipe) • Basement installation where one foot clearance  from ground to termination is possible Wall  90° Elbow 12" Min. Not to Exceed (H) Limits Firestop Square  As Required  Termination  for (V), See  Chart for  45° Elbow Pi
                    
                    ページ14に含まれる内容の要旨 
                    
                        VENTING INSTALLATION INSTRUCTIONS Continued HORIZONTAL SYSTEM INSTALLATION  USING TWO 90° ELBOWS The following configurations show the minimum  vertical rise requirements for a horizontal system  using two 90° elbows. 45° Elbow Venting with Two 90° Elbows Horizontal (H ) +  1 Vertical (V) Horizontal (H ) Horizontal (H ) 1 2 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' max. 20' max. 20' max. 8' max. 20' max. Figure 17 - Horizontal Termination Configuration 
                    
                    ページ15に含まれる内容の要旨 
                    
                        Flat Ceiling Installation VENTING INSTALLATION  3 1. Cut a 10 /4" square hole in the ceiling using  INSTRUCTIONS the locating hole as a center point. The open- Continued 3 3 ing should be framed to 10 /4" x 10 /4" inside  dimensions, as shown in Figure 9 on page 10  INSTALLATION FOR vERTICAL  using framing lumber the same size as the  TERMINATION ceiling joists. If the area above the ceiling is  Note: Vertical restrictor must be installed in all  an insulated ceiling or an attic, nail firestop  
                    
                    ページ16に含まれる内容の要旨 
                    
                        Vertical Termination Configurations VENTING INSTALLATION  Figures 21 through 24 show four different con- INSTRUCTIONS figurations for vertical termination.  Continued Venting with Two 90° Elbows 5. Place the flashing over the pipe section(s)  Horizontal (H ) +  1 extending through the roof. Secure the base of  Vertical (V) Horizontal (H ) 2 the flashing to the roof and framing with roof- 5' min. 2' max. ing nails. Be sure roofing material overlaps the  6' min. 4' max. top edge of the flashing as
                    
                    ページ17に含まれる内容の要旨 
                    
                        VENTING INSTALLATION  INSTRUCTIONS Continued Vertical Venting V = 40' max. Note: Install  Note: Install  restrictor into  restrictor into  inner collar of  inner collar of  fireplace as  fireplace as  shown. shown. 45° Elbow 45° Elbow Figure 24 - Vertical Venting Configuration  With No Horizontal Run (Vertical Round  Venting with Two 90° Elbows High Wind Termination Shown) vertical (v ) Horizontal (H) 1 HIGH ALTITUDE INSTALLATION 5' min. 6' max. Your DESA direct-vent fireplace has been tested an
                    
                    ページ18に含まれる内容の要旨 
                    
                        Number Description VENTING INSTALLATION  VKR-58 Roof Vent Kit, Galvanized   INSTRUCTIONS  (Includes: 45° Elbow, 7"-12"   Continued  Adjustable Pipe, Flue Restrictor,    Vertical High Wind Termination,  45° Starter  Elbow 2' Pipe, 4' Pipe, Wall Firestop,    Storm Collar, Roof Flashing   [0/12 - 6/12], 26 Screws) VKC-58 Corner Vent Kit, Galvanized   (Includes 45° Elbow, 7"-12"    Adjustable Pipe, Wall Firestop,   12"   Horizontal Termination, 6" Pipe,   Extension  90° Elbow, 18 Screws) HHTK-58 Hig
                    
                    ページ19に含まれる内容の要旨 
                    
                        5.  Mount speed control box to switch bracket  FIREPLACE  by placing the plastic control shaft forward  INSTALLATION through the round opening in the switch  bracket (see Figure 27). CHECK GAS TYPE 6.  While supporting speed control, secure control  Use proper gas type for the fireplace unit you are  shaft with lock nut by pushing and turning  installing. If you have conflicting gas types, do not  lock nut with pliers clockwise until it is tight  install fireplace. See retailer where you purchas
                    
                    ページ20に含まれる内容の要旨 
                    
                        FaV na S ria wbl itce h  Off On 110/115 M Blo otw or er V.A.C. Black Black White White Green 3.  Place the blower against the lower rear wall of  FIREPLACE  the firebox outer wrapper with the exhaust port  INSTALLATION directed upward and the thermodisc positioned  Continued up near the fireplace bottom. The thermodisc  must be oriented near the fireplace bottom as  shown in Figure 29 in order to sense tempera-  CAUTION: Never touch the  ture and properly operate. The blower will be  blower whee