UNVENTED (VENT-FREE) GAS COMPACT CLASSIC HEARTH 
DUAL BURNER FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
Shown with Optional Cabinet Mantel/Hearth Base Accessory
THERMOSTAT MODELS
VDCFTNB AND VDCFTPB
REMOTE-READY MODELS
VDCFRPB AND VDCFRNB
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable 
vapors and liquids in the vicinity of thi
                    
                    ページ2に含まれる内容の要旨 
                    
                        WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation  and operational procedures. For assistance or addi- tional information consult a qualified installer, service  agency or the gas supplier. WARNING: This is an unvented gas-fired heater. It uses  air (oxygen) from the room in which it is installed. Provi- sions for adequate combustion and ventilation air must  be provided. Refer to Ai
                    
                    ページ3に含まれる内容の要旨 
                    
                        SAFETY INFORMATION  WARNING: Do not allow fans  to blow directly into the fireplace.   WARNING: This product con- Avoid any drafts that alter burner  tains and/or generates chemicals  flame patterns. Ceiling fans can  known to the State of California  create drafts that alter burner  to cause cancer or birth defects  or other reproductive harm. flame patterns. Altered burner  patterns can cause sooting. IMPORTANT: Read this owner’s  Due to high temperatures, the  manual carefully and completely  ap
                    
                    ページ4に含まれる内容の要旨 
                    
                        11. Do not run fireplace SAFETY INFORMATION • where flammable liquids or vapors are used  Continued or stored. 1. This appliance is only for use with the type  • under dusty conditions. of gas indicated on the rating plate. This ap- 12. Do not use this fireplace to cook food or burn  pliance is not convertible for use with other  paper or other objects. gases.  13. Never place any objects in the fireplace or  2. Do not place propane/LP supply tank(s) in- on logs. side any structure. Locate propane/L
                    
                    ページ5に含まれる内容の要旨 
                    
                        L     I   P               F     F     O       L O PRODUCT LOCAL CODES Install and use fireplace with care. Follow all local  IDENTIFICATION codes. In the absence of local codes, use the lat- Fireplace est edition of The National Fuel Gas Code ANSI  Cabinet Z223.1/NFPA 54*. *Available from: Hood  American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 Screen  National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 PRODUCT FEATURES Log SAFETY PILOT This fir
                    
                    ページ6に含まれる内容の要旨 
                    
                        Louver HOOD ASSEMBLY Sheet Metal  Firebox  Screws Top  WARNING: Always have  screen in place before operating  fireplace. This prevents exces- sive temperatures on fireplace  surfaces. Hood  WARNING: Failure to position  the parts in accordance with these  diagrams or failure to use only  Figure 3 - Assembling Hood parts specifically approved with  this fireplace may result in prop- AIR FOR COMBUSTION  erty damage or personal injury. AND VENTILATION Tools Required: • Phillips screwdriver • slotted s
                    
                    ページ7に含まれる内容の要旨 
                    
                        Confined and Unconfined Space AIR FOR COMBUSTION  The National Fuel Gas Code, ANSI Z223.1/NFPA  AND VENTILATION 54 defines a confined space as a space whose  Continued volume is less than 50 cubic feet per 1,000 Btu  3 per hour (4.8 m per kw) of the aggregate input  PROVIDING ADEQUATE  rating of all appliances installed in that space and  VENTILATION  an unconfined space as a space whose volume is  The following are excerpts from National Fuel  not less than 50 cubic feet per 1,000 Btu per hour  3 Ga
                    
                    ページ8に含まれる内容の要旨 
                    
                        VENTILATION AIR AIR FOR COMBUSTION  Ventilation Air From Inside Building  AND VENTILATION This fresh air would come from an adjoining un- Continued confined space. When ventilating to an adjoining   Example:  unconfined space, you must provide two perma-  30,000  Gas water heater  _________ Btu/Hr nent openings: one within 12" of the ceiling and  + 10,000  Vent-free fireplace  _________ Btu/Hr one within 12" of the floor on the wall connecting  = 40,000  Total  _________ Btu/Hr the two spaces (see o
                    
                    ページ9に含まれる内容の要旨 
                    
                        INSTALLATION  CAUTION: This fireplace cre- NOTICE: This heater is intended  ates warm air currents. These  for use as supplemental heat.  currents move heat to wall sur- Use this heater along with your  faces next to fireplace. Installing  primary heating system. Do not  fireplace next to vinyl or cloth  install this heater as your pri- wall coverings or operating  mary heat source. If you have a  fireplace where impurities (such  central heating system, you may  as, but not limited to, tobacco  run
                    
                    ページ10に含まれる内容の要旨 
                    
                        For convenience and efficiency, install fireplace INSTALLATION • where there is easy access for operation, inspec- Continued tion and service INSTALLATION ITEMS • in coldest part of room Before installing fireplace, make sure you have  An optional blower kit is available from your  the items listed below. dealer. See Accessories, page 40. If planning to use  • external regulator (supplied by installer, for  blower, follow instructions provided with blower  propane/LP units only) for power source. •
                    
                    ページ11に含まれる内容の要旨 
                    
                        INSTALLATION  WARNING: If pre-wiring, do  Continued not connect wiring to any electri- BUILT-IN FIREPLACE  cal source at this time. INSTALLATION Install fireplace electrical outlet  Built-in installation of this fireplace involves  and connect wiring to outlet  installing fireplace into a framed-in enclosure.  This makes the front of fireplace flush with wall.  before connecting to electrical  An optional trim kit accessory is available (see  source. The fireplace electri- Accessories, page 40). Trim
                    
                    ページ12に含まれる内容の要旨 
                    
                        L I P F F O L O Mantel Shelf INSTALLATION 10" Note: Continued 8" All vertical 10. If using optional trim kit, install the trim after measurements 6" are from top of final finishing and/or painting of wall. See  1 2 /2" fireplace instructions included with trim accessory for  opening to  attaching trim. bottom of mantel shelf. All IMPORTANT: When finishing your firebox,  measurements combustible materials such as wall board, gypsum  are in inches. board, sheet rock, drywall, plywood, etc. may be  b
                    
                    ページ13に含まれる内容の要旨 
                    
                        L   I     P             F       F     O       L O 12. Install gas line. See Connecting To Gas Sup- INSTALLATION ply, page 16.  Continued 13. Check for leaks. See Checking Gas Connec- 4. Place mantel around fireplace on base (see  tions, page 17.  Figure 12). 14. Place mantel around fireplace. Be careful not  5. Assemble perimeter trim kit. See Assembling  to damage wall or mantel. Perimeter Trim. 15. Place perimeter trim kit on the shoulder screws  6. Firmly snap perimeter trim kit on shoulder  lo
                    
                    ページ14に含まれる内容の要旨 
                    
                        L   I     P             F       F     O       L 3 2 1 O 4. Carefully disconnect green and white wires at  INSTALLATION their insulated connectors (see Figure 15). Continued 5. In top of the fireplace cabinet, locate the four  2. Remove 4 screws from upper louver (see  mounting holes on the outer casing. Align  Figure 11, page 12). Save these screws.  these four holes with those on the blower  3. Pull upper louver straight out from the cabinet. Be  bracket assembly. Attach blower bracket as- caref
                    
                    ページ15に含まれる内容の要旨 
                    
                        L   I     P             F       F     O       L 3 2 1 O   5.  Test to make sure blower is working properly.  INSTALLATION 6. Reinstall upper louver beginning with bottom  Continued screws (see Figure 11, page 12) and close  For Built-In Installation lower louver.  Extension Cord  WARNING: A licensed elec- Use extension cord if needed. The cord must have  trician must connect the wiring  a three-prong, grounding plug and a three-hole re- harness to electrical supply  ceptacle. Make sure cord is i
                    
                    ページ16に含まれる内容の要旨 
                    
                        Installation must include an equipment shutoff  INSTALLATION valve, union and plugged 1/8" NPT tap. Locate NPT  Continued tap within reach for test gauge hook up. NPT tap  CONNECTING TO GAS SUPPLY must be upstream from heater (see Figure 20). IMPORTANT: Install equipment shutoff valve   WARNING: This appliance  in an accessible location. The equipment shutoff  requires a 45° male flare fitting  valve is for turning on or shutting off the gas to  the appliance. 5/8"-18 UNF (Unified National Fine  Ch
                    
                    ページ17に含まれる内容の要旨 
                    
                        L I P F F O L O 4. Check all gas connections for leaks. See  INSTALLATION Checking Gas Connections, below. Feed  Continued flexible gas line into fireplace. Make sure the  We recommend that you install a sediment trap in  entire flexible gas line is in fireplace.  supply line as shown in Figure 20, page 16. Locate  sediment trap where it is within reach for cleaning.  Install in piping system between fuel supply and  heater. Locate sediment trap where trapped mat- ter is not likely to freeze. A sedi
                    
                    ページ18に含まれる内容の要旨 
                    
                        Pressure Testing Fireplace Gas  INSTALLATION Connections Continued 1. Open equipment shutoff valve (see Figure 23). 2. Open main gas valve located on or near gas   CAUTION: Make sure exter- meter for natural gas or open propane/LP  nal regulator has been installed  supply tank valve. between propane/LP supply and  3. Make sure control knob of fireplace is in the  fireplace. See guidelines under OFF position. , 4. Check all joints from equipment shutoff  Connecting to Gas Supply valve to gas regula
                    
                    ページ19に含まれる内容の要旨 
                    
                        Installing 9-Volt Battery in Hand-Held  INSTALLATION Remote Control Unit  Continued 1. Remove battery cover on back of remote  OPTIONAL WIRELESS HAND-HELD  control unit. REMOTE CONTROL ACCESSORIES  2. Attach terminal wires to the battery (not in- cluded). Place battery into the battery housing. Remote-Ready Models Only  3.  Replace battery cover onto remote control unit.  (HRC100 Series & HRC200 Series) Battery  Installing Receiver Cover Remote Control Unit 1.  Disconnect wires from the control 
                    
                    ページ20に含まれる内容の要旨 
                    
                        7. Install the base onto the wall with the pro- INSTALLATION vided screws. Continued 8. Move the temperature adjustment back and forth  4. Gently remove the cover of the thermostat  to insure the bimetal is free from restrictions. from the base. Grasp the sides of the cover  9. Replace the cover onto the base. (Upon in- firmly and pull to separate from the base. stallation, the thermostat must be allowed to  5. Feed the electrical wires through the rectangular  stabilize at room temperature for a