ページ1に含まれる内容の要旨 
                    
                        ITW Dynatec ITW Dynatec GmbH
OPERATIONS&SERVICEMANUAL
An Illinois Tool Works Company Industiestrasse 28
Manual 50 -05
31 Volunteer Drive D-40822 Mettmann, Germany
Revised 1/23/04
Hendersonville, TN 37075 USA Telephone 49.2104.915.0
Telephone 615.824.3634 FAX 49.210.2104.915.111
FAX 615.264.5222
ITW Dynatec K.K.
Daiwashinagawa Bldg., 7-15 Konan, 3-Chome
Minata-Ku, Tokoyo 108 Japan
Telephone 81.3.3450.5901
FAX 81.3.3450.8405
Adhesive Application Solutions  ISO 9001 Certified
TPC2 TIME-BASED PATTE
                    
                    ページ2に含まれる内容の要旨 
                    
                        c.1999 Page ii TPC-2 TIMERManual 50-05 Revised 1/99 ITW Dynatec An Illinois Tool Works Company Adhesive Application Solutions                                                                                                                                                                                                                                                                                                                                                                                       
                    
                    ページ3に含まれる内容の要旨 
                    
                        ITW Dynatec c. 1999  Page iii  TPC-2 TIMER Manual #50-56  Revised 1/99     TABLE OF CONTENTS     CHAPTER 1:DESCRIPTION   General Description ...................................................................................................................................... 1-1  Specifications................................................................................................................................................ 1-2  How to Use this Manual.................................
                    
                    ページ4に含まれる内容の要旨 
                    
                        Page iv   ITW Dynatec c. 1999  Revised 10/99                                                                     TPC-2 TIMER Manual #50-05      CHAPTER 5: TROUBLESHOOTING  Controller Glues Every Other Sheet.............................................................................................................. 5-1   GlueLine Moves or Changes Length............................................................................................................. 5-1   Glue Applicators Will Not Act
                    
                    ページ5に含まれる内容の要旨 
                    
                        ITW Dynatec c. 1999  Page 1 - 1  TPC-2 TIMER Manual #50-05  Revised 11/04    Chapter 1  DESCRIPTION   Description  The ITW Dynatec TPC-2 Timer is a microprocessor-based electronic control system. It  may be used in any process that requires the timed actuation of electrical output devices  and has the ability to count those actuations and take varied actions based upon the count.  It was specifically developed to control glue application valves used in adhesive systems.  Examples of applications
                    
                    ページ6に含まれる内容の要旨 
                    
                        Page 1 - 2   ITW Dynatec c. 1999  Revised 1/99                                                                     TPC-2 TIMER Manual #50-05    The TPC-2 possesses a PALLETISING facility that provides an easy means of applying  glue to a specified number of objects, then passing (or skipping) a specified number of  objects. The display continually updates itself to inform the operator of the current  COUNT.  A key-actuated system lock is provided on the Controller’s front panel. This lock preven
                    
                    ページ7に含まれる内容の要旨 
                    
                        ITW Dynatec c. 1999  Page 2 - 1  TPC-2 TIMER Manual #50-05  Revised 8/99    Chapter 2  INSTALLATION  The ITW Dynatec TPC-2 Timer is very easy to install and operate. It is highly  recommended, however, that the entire contents of this manual be read before installation  to become familiar with the many features of this equipment and to avoid potential safety  hazards.  WARNING: Line voltage is present at several places inside this Control Unit  when it is connected to an AC power source. Electri
                    
                    ページ8に含まれる内容の要旨 
                    
                        Page 2 - 2   ITW Dynatec c. 1999  Revised 1/04                                                                     TPC-2 TIMER Manual #50-05  Supplied Equipment  The TPC-2 Control Kit is supplied with the following equipment. Please inventory these  parts immediately upon unpacking the Control Kit to assure all items are present.    Qty Description Part Number  1 Control Unit, TPC-2 106076  1 Purge Control 106078  1 Output Kit (contains two 10 foot drive output cables, L21754  one end with conne
                    
                    ページ9に含まれる内容の要旨 
                    
                        ITW Dynatec c. 1999  Page 2 - 3  TPC-2 TIMER Manual #50-05  Revised 11/04  Optional Accessories  The following accessories are available from ITW Dynatec for use with the TPC-2  Control Kit:    Description Part Number  Mini Reflective Photo Sensor Assembly, 2ms L21746  Response (6’ cord)  Reflective Photo Sensor Assembly, 1ms Response L21701  (6’ cord)  Fiber Optic Photo Sensor Assembly (6’ cord) L21745  Foot Switch Assembly (10’ cord) 106114  Trigger Extension Cable, 10’ (may be used with any L
                    
                    ページ10に含まれる内容の要旨 
                    
                        Page 2 - 4   ITW Dynatec c. 1999  Revised 11/04                                                                     TPC-2 TIMER Manual #50-05    The following steps should be employed to change the Control Unit’s operating voltage  from the factory pre-set value:  1. Remove the 6 screws that secure the upper and    lower portions of the Control Unit display panel  using a cross-point screwdriver.  2. Remove the lower panel (the portion housing the  power switch and fuse holder) from the case tak
                    
                    ページ11に含まれる内容の要旨 
                    
                        ITW Dynatec c. 1999  Page 2 - 5  TPC-2 TIMER Manual #50-05  Revised 8/99  Dimensions  1.19" 3.5" 3.5" 1.19" 5.25” 30mm 89mm 89mm 30mm 133.4mm 0.27" 7mm 11.56" 11.56" 294mm 294mm 10.81" 275mm 9.75" .5" .375" 248mm 13mm 10mm   Locating the TPC-2 for Installation  Mount the TPC-2 in a cool, dry, clean and well-ventilated area. Allow access space at the  front and sides for operation and maintenance. Do not place the Control Unit where it is  subject to high heat and humidity, in traffic areas or wh
                    
                    ページ12に含まれる内容の要旨 
                    
                        Page 2 - 6   ITW Dynatec c. 1999  Revised 12/99                                                                     TPC-2 TIMER Manual #50-05  Installing the TPC-2 and Accessories  1. Mount the TPC-2 Control Unit as close to the Trigger Input Device and the Glue  Applicators as is possible.  2. Mount the Trigger Device and Glue Applicator(s) in the desired locations. Connect the  Drive Output Cable(s) to the Glue Applicator(s).  3. Install the Automatic Tip Sealer(s) to the Glue Applicator(s) (c
                    
                    ページ13に含まれる内容の要旨 
                    
                        ITW Dynatec c. 1999  Page 2 - 7  TPC-2 TIMER Manual #50-05  Revised 11/04  230VAC Power Cord Wiring    WIRE COLOR DESIGNATION  Brown or Black Power (+)  Blue or White Neutral (-)  Green Ground  CAUTION: Avoid the installation of input or output cords near or parallel to  power lines from other machinery. The resulting electrical “noise” can produce  adverse effects on the TPC-2 Control Unit which could result in unreliable    operation.  Receptacle Assignments  Below are the pin assignments for 
                    
                    ページ14に含まれる内容の要旨 
                    
                        Page 2 - 8   ITW Dynatec c. 1999  Revised 12/99                                                                     TPC-2 TIMER Manual #50-05  Important Note:  The TPC-2 is usually connected to non-polarity-sensitive solenoids using the ITW  Dynatec Output Kit (L21754) supplied as a part of the TPC-2 Control Unit Kit. As such,  it is not important to which terminal the two wires of the Output Kit cables are connected.  Polarity Sensitive solenoids, such as ITW Dynatec P/N 030A057 require attenti
                    
                    ページ15に含まれる内容の要旨 
                    
                        ITW Dynatec c. 1999  Page 3 - 1  TPC-2 TIMER Manual #50-05  Revised 1/99    Chapter 3  OPERATION & PROGRAMMING    Start-Up Procedure  1. Open the latch on the right side of the TPC-2 Control Unit and swing open the lid.  2. Two keys for the Programming Security feature should be attached to the inside of the  lid. Remove these keys and unwrap them.  3. Insert one of the keys into the lock on the Display Panel. Assure the key is in the  UNLOCKED (key tab vertical) position.  4. Remove the key and
                    
                    ページ16に含まれる内容の要旨 
                    
                        Page 3 - 2   ITW Dynatec c. 1999  Revised 1/99                                                                    TPC-2 TIMER Manual #50-05  Programming Conventions  The TPC-2 employs the following programming conventions:  1. All CHANNEL modifications are performed on the Program displayed (Pr-1, -2, -3 or  -4) when the MEMORY LED is illuminated.  2. Depressing the CHANNEL 1 or CHANNEL 2 buttons allows programming of the  parameters for that channel of the selected Program (Pr-1, -2, -3 or -4).
                    
                    ページ17に含まれる内容の要旨 
                    
                        ITW Dynatec c. 1999  Page 3 - 3  TPC-2 TIMER Manual #50-05  Revised 1/99  System Status Lights  There are four LED’s in the top right corner of the Display Panel that provide an  indication of the current system status. These lights are described in further detail below:  Drive 1 & Drive 2  These LED’s provide an indication of the current Drive Output activity. The LED’s will  be in one of the following states:    STATUS LIGHT MEANING  No Illumination: There is no Drive Output activity  GREEN: T
                    
                    ページ18に含まれる内容の要旨 
                    
                        Page 3 - 4   ITW Dynatec c. 1999  Revised 1/99                                                                    TPC-2 TIMER Manual #50-05  The A.T.S. output voltage is 48VDC at 5.4W for a 25ms duration. The output then drops  to a holding voltage of 16VDC. The TPC-2 activates the A.T.S. Drive immediately upon  receipt of Trigger Inputs. The Tip Sealing Device requires time to operate, the TPC-2  caters for this by allowing a 35ms dwell time from Trigger Input until the gluing program  will fun
                    
                    ページ19に含まれる内容の要旨 
                    
                        ITW Dynatec c. 1999  Page 3 - 5  TPC-2 TIMER Manual #50-05  Revised 1/99  PURGE Display Settings  DISPLAY MEANING  = = = 0 Activation of A.T.S. output only  = = = 1 Activation of A.T.S. and DRIVE 1 outputs  = = = 2 Activation of A.T.S. and DRIVE 2 outputs  3. Activation of the selected outputs occurs upon depressing the button on the Purge  Control Unit (106078) and continues until the button is released.    Trig Mode  The TRIG MODE (Trigger Mode) parameter allows the Operator to select the mann
                    
                    ページ20に含まれる内容の要旨 
                    
                        Page 3 - 6   ITW Dynatec c. 1999  Revised 1/99                                                                    TPC-2 TIMER Manual #50-05    TIME RANGE Display Settings  DISPLAY MEANING  0.001 Time Range Selection between 0.001 and  1.999 seconds  0.010 Time Range Selection between 0.01 and  19.99 seconds  NOTE: Maximum time settings (i.e. 1.999 or 19.99 seconds) represent the maximum  allowed cumulative time for DELAY and LINE duration of all four EVENTs in a  CHANNEL    Glue/Pass/Start  The