ページ1に含まれる内容の要旨 
                    
                        InstallatIon & operatIng InstructIons
ImperIal gas logs
 Fi36s Fi36sl Fi36m Fi36ml
 Fi42s Fi42sl Fi42m Fi42ml
For resIdentIal use
WarnIng: If the information in this manual 
is not followed exactly, a fire or explosion may 
result causing property damage, personal 
injury or loss of life.
—	 Do	 not	 store	 or	 use	 gasoline	 or	 other	 flammable	
vapors and liquids in the vicinity of this or any other 
appliance.
—	 What	to	do	if	you	smell	gas
	 •	 Do	not	try	to	light	any	appliance.
	 •	 Do	 no
                    
                    ページ2に含まれる内容の要旨 
                    
                        please retaIn thIs manual For Future reFerence Installation and service must be performed by a qualified installer, service  agency or the gas supplier. t able of contents A.		 Listings	and	Code	 Approvals ...........................................................................................................................................3 B.		 Description	of	the	Imperial	Gas	Log	Set.............................................................................................................
                    
                    ページ3に含まれる内容の要旨 
                    
                        ImperIal gas log set InstallatIon InstructIons a. listings and code approvals The	Imperial	Series	Gas	Log	Set	has	been	tested	and	listed	in	the	U.S.	in	accordance	with	ansI Z21.60-1996 	(Gas	Log	 Set).	In	Canada	the	Imperial	Series	Gas	Log	Set	has	been	tested	and	approved	in	accordance	with	cga 2.26-m96.	It	has	 been	listed	by	Underwriters	Laboratories	Inc.	for	installation	and	operation	in	the	United	States	and	Canada	as	described	 in	these	Installation	and	Operating	Instructions.	 All	componen
                    
                    ページ4に含まれる内容の要旨 
                    
                        These	gas	log	sets	are	available	with	dif ferent	valve	systems.	 The	Fi36S,	Fi36SL,	Fi42S	and	Fi42SL 	sets	use	a	separate	 regulator	and	valve	system,	and	the	Fi36M,	Fi36ML,	Fi42M	and	Fi42ML 	sets	use	a	combination	control	with	an	intermit- tent	pilot.	Both	valve	systems	are	available	in	natural	or	propane	gas.	Only	the	“M”	Series	can	be	used	with	an	optional	 remote	control	(RC-BA TT -HTL). Conversion	kits	to	convert	from	natural	gas	to	propane	or	from	propane	to	natural	gas	are	available. •	 T
                    
                    ページ5に含まれる内容の要旨 
                    
                        ImperIal gas log set InstallatIon InstructIons c. Important Information Installer:	Please	leave	these	instructions	with	the	owner . owner: Please retain these instructions for future reference. Important: read these instructions carefully before making installation. •	 This	 appliance	 must	 be	 installed	 only	 in	 a	 solid-fuel	 burning	 (woodburning)	 fireplace	 with	 a	 working	 flue	 and	 constructed	of	noncombustible	materials. •	 The	 appliance	 area	 must	 be	 kept	 clear	 and	 free	 fro
                    
                    ページ6に含まれる内容の要旨 
                    
                        d. step-by-step Installation 1. unpack the log set b.	 Remove	 the	 four	 screws	 that	 secure	 the	 top	 pan	 to	 Carefully	remove	all	parts	from	the	shipping	container .	 the	base	of	the	appliance.	See	Figure	4. Y our	set	includes	four	fiber	logs,	a	burner	assembly ,	the	 grate	assembly ,	fire	embers,	lava	rock,	damper	stop,	and	 10”	flex	connector . 2. Install the damper stop T o	install	the	damper	stop:	Open	the	damper	to	the	fully	 open	position	and	secure	it	open	with	the	stop	as	shown	in	
                    
                    ページ7に含まれる内容の要旨 
                    
                        ImperIal gas log set InstallatIon InstructIons f. Bleed the gas	 line	 to	 extract	 any	 air	 that	 may	 have	 b e e n 	 t r a p p e d 	 i n s i d e 	 t h e 	 p i p e . 	 A l l 	 c o n n e c t i o n s	 must	 be	 tightened	 and	 checked	 for	 leaks	 with	 a	 commercially	 available,	 non-corrosive	 leak	 check	 s o l u t i o n . 	 B e 	 s u r e 	 t o 	 r i n s e 	 o f f 	 t h e 	 s o l u t i o n 	 w h e n 	 d o n e	 l e a k 	 t e s t i n g . 	 D O 	 N O T 	 U S E 	 A N 	 O P E N 	 F L A M E . 	 T
                    
                    ページ8に含まれる内容の要旨 
                    
                        7. place the logs a.	 Rear	Log c.	 T op	Right	Log 	 The	 rear	 log	 is	 supplied	 with	 locating	 slots	 in	 the	 	 The	 top	 right	 log	 is	 supplied	 with	 locating	 slots	 in	 b a s e 	 o f 	 t h e 	 l o g . 	 L o c a t e 	 t h e 	 r e a r 	 l o g 	 o v e r 	 t h e 	 l o c a t i n g	 the	 base	 of	 the	 log.	 Locate	 the	 log	 over	 the	 two	 tabs	at	the	rear	of	the	top	pan.	See	Figure	9. locating pins found in the rear log and the front log.  See	Figure	1 1. Figure 9 - rear log placement Fig
                    
                    ページ9に含まれる内容の要旨 
                    
                        ImperIal gas log set InstallatIon InstructIons 8. Intermittent pilot Ignition a.	 Appliance	Requirements:	 This	appliance	does	not	require	1 10V AC	supply	for	operation.	 1) A wiring	 diagram	 is	 shown	 in	 Figure	 13.	 A 	 battery	 pack	 is	 supplied	 with	 the	 appliance.	 This	 appliance	 requires	the	use	of	two	D-cell	batteries	(not	supplied	with	the	appliance)	for	operation. 2)	 I n 	 t h e 	 e v e n t 	 o f 	 a 	 p o w e r 	 o u t a g e , 	 t h e 	 a p p l i a n c e 	 w i l l 	 c o n t i 
                    
                    ページ10に含まれる内容の要旨 
                    
                        e. operating Instructions for the “m” series FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion  may result causing property damage, personal injury or loss of life. A. This appliance has an intermittent pilot. When C. Do not use this appliance if any part has been  lighting the pilot, follow these instructions  under water. Immediately call a qualified service  exactly. technician to inspect the appliance and to  replace any part o
                    
                    ページ11に含まれる内容の要旨 
                    
                        ImperIal gas log set InstallatIon InstructIons F. operating Instructions for the “s” series FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may  result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lit by C. Use only your hand to push in or turn the gas control  hand. When lighting the pilot, follow these  knob. Never use tools. If the knob will not push in or  instructions 
                    
                    ページ12に含まれる内容の要旨 
                    
                        g. glass doors If	your	fireplace	is	equipped	with	a	glass	door ,	the	glass	doors	should	be	in	the	full	open	position	when	the	appliance	is	 operating.	Operating	the	fireplace	with	the	glass	doors	closed	will	block	the	radiant	heat	output	of	the	fireplace	and	may	 cause	incomplete	combustion	of	the	natural	or	propane	gas	fuel. Important! A l w a y s	e n s u r e	t h at	t h e	w i r e	fi r e p l a c e	s c r e e n	i s	c l o s e d	w h e n	t h e	fi r e p l a c e	i s	o p e r at i n g . h. cleaning Y our
                    
                    ページ13に含まれる内容の要旨 
                    
                        ImperIal gas log set InstallatIon InstructIons 2. possible cures a.	 The	damper	needs	to	be	opened	further . b.	 The	fireplace	opening	needs	to	be	reduced	by	adding	a	drop	panel	across	the	top	under	the	lintel. c.	 The	 air	 supply	 from	 outdoors	 needs	 to	 be	 increased.	 Open	 the	 outside	 air	 kit	 if	 the	 fireplace	 is	 so	 equipped,	 or	crack	open	a	door	or	window . d.	 If	necessary ,	seek	expert	advice.	Do	not	operate	this	appliance. 3. cleaning Periodic	examination	and	cleaning	of	the
                    
                    ページ14に含まれる内容の要旨 
                    
                        FI36m service parts diagram Beginning manufacturing date: n/a  36” Imperial log set ending manufacturing date: active Replacement	Parts	-	“S”	Series 5 6 7 8 9 10 11 14 15 12 13 16 17 18 log set assembly 3 4 1 2 part number list on following page. 14 33734 Rev J 1/11                                                                                                                                                                                                                                          
                    
                    ページ15に含まれる内容の要旨 
                    
                        FI36m Beginning manufacturing date: n/a  service parts list ending manufacturing date: active 36” Imperial log set IMPOR T ANT :	 THIS	 IS	 DA TED	 INFORMA TION.	 When	 requesting	 service	 or	 replacement	 parts	 for	 your	 appliance	 please	 provide	 model	 number	 and	 serial	 number .	 All	 parts	 listed	 stocked  in	this	manual	may	be	ordered	from	an	authorized	dealer . at depot Item descrIptIon comments part numBer 1 Back	Log SR V32233 2 Front	Log SR V32234 3 T op	Right	Log SR V33732 4 T o
                    
                    ページ16に含まれる内容の要旨 
                    
                        FI42m service parts diagram Beginning manufacturing date: n/a  ending manufacturing date: active 42” Imperial log set 5 6 7 8 9 10 11 14 15 12 13 16 17 18 log set assembly 3 4 1 2 part number list on following page. 16 33734 Rev J 1/11                                                                                                                                                                                                                                                                         
                    
                    ページ17に含まれる内容の要旨 
                    
                        FI42m Beginning manufacturing date: n/a  service parts list ending manufacturing date: active 42” Imperial log set IMPOR T ANT :	 THIS	 IS	 DA TED	 INFORMA TION.	 When	 requesting	 service	 or	 replacement	 parts	 for	 your	 appliance	 please	 provide	 model	 number	 and	 serial	 number .	 All	 parts	 listed	 stocked  in	this	manual	may	be	ordered	from	an	authorized	dealer . at depot Item descrIptIon comments part numBer 1 Back	Log SR V32233 2 Front	Log SR V32234 3 T op	Right	Log SR V33732 4 T o
                    
                    ページ18に含まれる内容の要旨 
                    
                        n. t roubleshooting - “m” series With	proper	installation	and	maintenance,	your	new	decorative	gas	appliance	should	provide	years	of	trouble-free	service.	 If	you	do	experience	a	problem,	refer	to	the	troubleshooting	guide	below .	 This	guide	will	assist	you	or	a	qualified	service	 technician	in	the	diagnosis	of	problems	and	the	corrective	action	to	be	taken. symptoms possible causes corrective action 1 Pilot	sparks,	but	will	not	light	 a. Main	gas	shutof f	valve	closed. Make	sure	that	the	shuto
                    
                    ページ19に含まれる内容の要旨 
                    
                        ImperIal gas log set InstallatIon InstructIons o. trouBleshootIng - “s” serIes symptoms possible causes corrective action 1 Match	will	not	light	pilot. a. Main	gas	shutof f	valve	closed. Make	sure	that	the	shutof f	valve	located	on		the	 incoming	gas	line	is	open. b. Air in the gas line. Light	a	match.	 T urn	valve	knob	to	“PILOT”	position	 and	depress.	Keep	match	near	pilot	burner	until	it	 lights.  c. V alve	knob	is	in	“OFF”	position T urn	valve	knob	to	“PILOT”	position	and	depress.	 Keep	matc
                    
                    ページ20に含まれる内容の要旨 
                    
                        p. accessory parts (For “m” series only) The	following	accessory	parts	can	be	obtained	from	your	dealer .	 The	wireless	remote	control	switch	is	supplied	 with	installation	instructions	packaged	with	them.	Should	you	need	additional	information	please	contact	your		 dealer	for	more	information	or	visit:	www .hpba.org/staysafe.			 remote control rc-Batt -htl  20 33734 Rev J 1/11