ページ1に含まれる内容の要旨 
                    
                        R
 
INSTALLATION 
AND 
OPERATING 
 
 
INSTRUCTIONS
Gas Griddles
MODELS: GGT-18H, -24H, -36H, -48H
&
MODELS: GGM-18H, -24H, -36H, 48H
(US & Canadian units are convertible and are assembled for Natural Gas)
(European units are not convertible and assembled for the appropriate gas)
 
 
IMPORTANT FOR FUTURE REFERENCE
 
Please complete this information and retain this manual for the life of the equipment. For 
 
Warranty Service and/or Parts, this information is required.
 
         Model Number     
                    
                    ページ2に含まれる内容の要旨 
                    
                        CAUTION: These models are designed, built, and sold for commercial use. If these  models are positioned so the general public can use the equipment, make sure that           cautions, warnings, and operating instructions are clearly posted near each unit so that  ! ! anyone using the equipment will use it correctly and not injure themselves or harm the  equipment. WARNING: Improper installation, adjustment, alteration, service or maintenance can        cause property damage, injury or death. Rea
                    
                    ページ3に含まれる内容の要旨 
                    
                        IMMEDIATELY INSPECT FOR SHIPPING DAMAGE All containers should be examined for damage before and during unloading. The freight carrier has  assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent  or concealed, a claim must be made with the delivering carrier. A)  Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be signed  by the carrier representative (Driver). If this is not done, the carrier may 
                    
                    ページ4に含まれる内容の要旨 
                    
                        WARNING: Keep the appliance free & clear of all combustible substances. If gas odor is         detected at any time, immediately shut unit down at the main shutoff  valve. Do not permit  ! ! any open flames in the area of the appliance. Immediately contact an authorized Service  Agency or your local Gas Supplier for service.     WARNING: Do not obstruct either the air inlet (underneath unit) or the ventilation air (back     ! ! of unit). Provisions must be provided to provide an adequate air sup
                    
                    ページ5に含まれる内容の要旨 
                    
                        Caution: DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and  water solution before operating unit. THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.  Noncombustible clearances: 0" sides (0 mm) 0" rear (0 mm) 4” floor (102mm) Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the  flue. Adequate clearance for air openings into the combustion chamber is required. Do not plac
                    
                    ページ6に含まれる内容の要旨 
                    
                        5. Turn the burner knobs to "HI". If the burner does not ignite, promptly open the pilot valve more. If the  pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot flame  should be as small as possible but large enough to guarantee reliable ignition of the burners when  the knobs are turned to "HI". Lighting main burner To light burner, turn knob to “max.” Then back off to the desired flame level. The range of adjustment is  virtually infinite between high a
                    
                    ページ7に含まれる内容の要旨 
                    
                        CLEANING / MAINTENANCE CAUTION: Use only non-abrasive cleaners. Abrasive cleaners could scratch the finish of your unit,  marring it’s appearance and making it susceptible to dirt accumulation. Do Not use steel wool, other  abrasive  cleaners or cleaners/sanitizers containing chlorine,    iodine, ammonia or bromine  ! !    chemicals as these will deteriorate the stainless steel and glass material and shorten the life of the  unit.  Initial Cleaning: Prior to operating your new griddle, thoroughl
                    
                    ページ8に含まれる内容の要旨 
                    
                        CONVERSION  GGT Instructions are for conversion from Natural Gas to Propane (L.P.) on all GGT models . The conversion should be done before connecting the unit to the gas supply. 1. Remove the knobs and front panel. 2. Remove the supply tubes that go between the thermostats and the orifice bracket. 3. Change the orifices to the size recommended for propane (L.P.). For units with a pilot safety valve  you must also change the pilot orifice to the other pilot orifice supplied. 4. Replace the suppl
                    
                    ページ9に含まれる内容の要旨 
                    
                        CALIBRATION PROCEDURE FOR GGT GRIDDLES Locate the reading positions  Make sure the griddle surface is clean. Grease or food particles on the griddle will result in inaccurate  thermostat calibration.  Mark the locations where the temperature probe will be placed for testing. See the sketch provided. Starting  from the left side of the griddle measure 8” to the right and 10-5/8” from the rear splash guard. With a felt tip  pen mark this location. This is the location directly over the center of t
                    
                    ページ10に含まれる内容の要旨 
                    
                        TROUBLESHOOTING GUIDE PROBLEM                                                              POSSIBLE CAUSE Heat does not come on Thermostat is bad. when thermostat is turned on. Pilot burner not lit. Gas valve is bad. Pilot burner will not light. Obstructed pilot orifice. Pilot gas turned off at automatic pilot. Automatic pilot valve is bad. Pilot burner will not stay lit. Thermocouple is bad. Thermocouple is not hot enough. Obstructed or wrong size pilot orifice. Gas supply is not purged of air.
                    
                    ページ11に含まれる内容の要旨 
                    
                        NOTES 11                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ページ12に含まれる内容の要旨 
                    
                        PARTS LISTS & EXPLODED VIEWS GGM GRIDDLES (EXPLODED VIEW) 1 14 9 56 2 46 47 12 22 6 23 10 18 24 4 45 21 48 50 42 11 29 3 15 39 49 7 44 43 41 17 40 20 19 13 16 25 31 35 5 26 38 28 32 37 33 27 30 34 8 36 12                                                                                                                                                                                                                                                                                                        
                    
                    ページ13に含まれる内容の要旨 
                    
                        GGM - PARTS LIST ITEM P/N        DESCRIPTION QTY. ITEM P/N DESCRIPTION QTY. 1 218215-20 Weldment, Griddle GGM-18 1 24 24251-00 Pan, Grease 18" Varies 218216-20 Weldment, Griddle GGM-24 1 24250-00 Pan, Grease 24" Varies 218217-20 Weldment, Griddle GGM-36 1 25 8861000 Label, Spec 1 218218-20 Weldment, Griddle GGM-48 1 26 218215-12 Panel, Back GGM-18 1 2 218215-11 Body, 18" Firebox GGM 1 218216-12 Panel, Back GGM-24 1 218216-11 Body, 24" Firebox GGM 1 218217-12 Panel, Back GGM-36 1 218217-11 Body, 
                    
                    ページ14に含まれる内容の要旨 
                    
                        GGT GRIDDLES (EXPLODED VIEW) 44 1 56 28 32 53 33 35 34 16 19 23 8 49 21 64 51 54 66 57 41 65 12 62 60 40 55 63 52 69 2 29 58 59 26 14 39 5 68 24 9 61 50 20 22 25 10 6 18 27 3 13 11 4 37 7 15 38 67 17 48 42 14                                                                                                                                                                                                                                                                                                    
                    
                    ページ15に含まれる内容の要旨 
                    
                        GGT (PARTS LIST) Item      P/N       Description                                Quan  Item      P/N       Description                               Quan 1 218219-60 Weldment, Griddle, GGT -18 1 30* 2300100 Bags, Poly 36x27x44 1 2 218220-60 Weldment, Griddle, GGT -24 1 32 1018064 Insulation, Thermostat Bulb 218221-60 Weldment, Griddle, GGT -36 1 33 8509300 Washer, Flat, SAE, 5/16 4 218222-60 Weldment, Griddle, GGT -48 1 34 8436200 8 Nut, Hex 5/16-18  S/S 2 2092614 Elbow, 3/8CC X 3/8NPT, No Hood V
                    
                    ページ16に含まれる内容の要旨 
                    
                         APW WYOTT EQUIPMENT LIMITED WARRANTY APW Wyott Foodservice Equipment Company warrants it's equipment against defects in materials and workmanship, subject to the  following conditions: This warranty applies to the original owner only and is not assignable. Should any product fail to function in its intended manner under normal use within the limits defined in this warranty, at the option of  APW Wyott such product will be repaired or replaced by APW Wyott or its Authorized Service Agency. APW W