ページ1に含まれる内容の要旨 
                    
                        For more information, visit www.desatech.com
B-VENT DECORATIVE GAS FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
MODELS M36(B,H), M42(B,H), VM36(B,H) AND VM42(B,H) NATURAL GAS
MODELS M36P(B,H), M42P(B,H), VM36P(B,H) AND VM42P(B,H) PROPANE/LP GAS
SAVE THIS BOOK
WARNING: If the information in these instructions 
This book is valuable. In addition to instructing you 
is not followed exactly, a fire or explosion may re-
on how to install and maintain your appliance, it 
sult causing property da
                    
                    ページ2に含まれる内容の要旨 
                    
                        2 TABLE OF CONTENTS Safety Information ........................................................................2 Cleaning and Maintenance .........................................................18 Unpacking ....................................................................................3 Wiring Diagram ...........................................................................18 Introduction ...................................................................................3 Service Hints .
                    
                    ページ3に含まれる内容の要旨 
                    
                        3 3 SAFETY INFORMATION INTRODUCTION Continued Models M36(P)(B,H), VM36(P)(B,H), M42(P)(B,H) and  VM42(P)(B,H) are vented gas fireplaces that use a millivolt gas  9. You must keep control compartments, burners and circulating  control valve with a millivolt ignition system. A 6" B-Type venting  air passages clean. More frequent cleaning may be needed due  system and a listed type vent cap are not supplied but are required  to excessive lint and dust from carpeting, bedding material, etc.  for prop
                    
                    ページ4に含まれる内容の要旨 
                    
                        4 GAS RATING - NATURAL INTRODUCTION  M36(B,H), VM36(B,H) M42(B,H), VM42(B,H) Continued Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5 in. WC (.87 kPa) 3.5 in. WC (.87 kPa)  CAUTION: Do not connect appliance before pressure  Minimum Supply Pressure: 4.5 in. WC (1.12 kPa) 4.5 in. WC (1.12 kPa) testing gas piping. Damage to gas valve may result and  Maximum Supply Pressure: 10.5 in. WC (2.66 kPa) 10.5 in. WC (2.66 kPa) an unsafe condition may be caused. Orifice Size: # 30 # 29
                    
                    ページ5に含まれる内容の要旨 
                    
                        5 5 SELECTING LOCATION PRE-INSTALLATION  To determine the safest and most efficient location for your appli- PREPARATION ance, you must take into consideration the following guidelines: 1. The location must allow for proper clearances (see Clearances, CLEARANCES next column). Minimum clearances to combustibles are: 2. Consider a location where heat output would not be affected  • Back and Sides of Outer Surround ..................... 0" min. by drafts, air conditioning ducts, windows or doors. • 
                    
                    ページ6に含まれる内容の要旨 
                    
                        6 PRE-INSTALLATION  PREPARATION Continued MANTEL CLEARANCES AND WALL DETAILS TOP VIEW A combustible mantle shelf maybe installed a maximum 12"  Outer Surround (229 mm) from the wall. Figures 5 and 6 show the minimum  Combustible allowable distances from various combustible mantle compo- Material May nents in relation to the fireplace opening. Be Used SAFE 12" Combustible 1 ZONE 1 /2" (38 mm) (229mm) Materials Max. 3" (76 mm) Header Max. 6" (152 mm) 6" (152mm) Max. A Perpendicular B Wall A   M36(
                    
                    ページ7に含まれる内容の要旨 
                    
                        7 7 These Dimensions Allow for a 3/4"  PRE-INSTALLATION  Clearance at Sides and Back of  Fireplace. However, 0" Clearance  PREPARATION is Permitted Continued D FRAMING C 1. Frame appliance enclosure as illustrated in Figures 7 and 8. A 3/4" Clearance  Not Required   Note: If a wall covering is used to line the enclosure, then all  at Nailing  measurements must be from the surface of the covering. Flanges  2. Place the appliance into the framing and secure it.  Note: If appliance is to be raised 
                    
                    ページ8に含まれる内容の要旨 
                    
                        8 Example 1: Shows the minimum allowable system height and  VENTING INSTALLATION lateral offset for a 60° degree or greater inclination. Code specifies  A B-type venting system must be connected to the appliance for  that offsets at 60° degrees or greater are considered horizontal and  venting to the outside of the building. must follow the 75% percent rule for lateral to total vertical system  height. Codes also allows only one offset in the total system when  The following section is provided a
                    
                    ページ9に含まれる内容の要旨 
                    
                        9 9 VENTING INSTALLATION  WARNING: This appliance must be properly con- Continued nected to a system and must not be connected to a  chimney flue servicing a separate solid fuel burning  Vent terminations must be located in accordance with height and  appliance. proximity rules of NFPA No. 54 or CAN/CGA B149. These rules  apply to vents at 12 in. diameter or less and require a minimum  height in accordance with the roof pitch and a minimum of 8 ft.  CHECKING FOR PROPER VENTING  distance from a ve
                    
                    ページ10に含まれる内容の要旨 
                    
                        O OUT IN 10 4. Connect wires to control circuit. Connect white wire to termi- INSTALLATION nal marked TH/TP on control valve. Connect red wire to male  blade connector provided at open end of safety circuit wiring  WALL SWITCH INSTALLATION (see Wiring Diagram, page 18). The installation of a wall switch allows you to activate the gas  5. Locate the battery clip mounted on the back of the receiver  control valve without the normal household electricity since the  (see Figure 16).  valve operates 
                    
                    ページ11に含まれる内容の要旨 
                    
                        11 11 Shutoff  INSTALLATION Typical Exterior Wall Gas  Valve Continued Shutoff Installation GAS LINE HOOK-UP Key  WARNING: Gas line hookup should be done by your  gas supplier or a qualified service person. Extension  WARNING: Before you proceed, make sure your  Figure 18 - Manual Shutoff Valve Installation gas supply is OFF. A manual shutoff valve has been included in the applianceʼs gas  1/2" NPT Incoming supply system. You may consider installing an extra gas shutoff  Black Iron Gas Line valve
                    
                    ページ12に含まれる内容の要旨 
                    
                        12 LOG PLACEMENT FOR M36, M36P, VM36 AND  INSTALLATION Continued VM36P MODELS 1. Place small front right log (log 1) on right front of grate as  EMBER AND PAN MATERIAL PLACEMENT shown in Figure 25. 1. Open the bag(s) of vermiculite and fill the entire burner pan  2. Place large back log (log 2) onto grate making sure notches  until the burner tube is completely covered (see Figure 22).  rest over grate as shown in Figure 25. 2. Smooth the pan material just even with edges of the burner  3. Place 
                    
                    ページ13に含まれる内容の要旨 
                    
                        13 13 LOG PLACEMENT FOR M42, M42P, VM42 AND  INSTALLATION Continued VM42P MODELS 1. Place large back log (log 1) onto grate making sure notches  5. Place the upper end of log 5 into notch on the left of log 2 (see  rest over grate (see Figure 29). Figure 27). Rest the lower end of log 5 on the grate as shown  2. Insert lower end of log 2A between the first two grate fingers  in Figure 28. and position the upper end into the notch on the front of log 1.  6. Insert the lower end of log 6 between the
                    
                    ページ14に含まれる内容の要旨 
                    
                        14 COMBUSTION AIR KIT MODEL AK4  INSTALLATION Continued (OPTIONAL) The outside air kit may be installed on the left side of the fireplace  5. Place the upper end of log 5 into the notch on the top inner  only. The vent can be installed through any outside wall a minimum  right of log 1 (see Figure 31). Rest the lower end of log 5 on  of three feet below fireplace termination cap. The handle to operate  the middle grate finger as shown in Figure 32. the damper door for the outside air inlet will be 
                    
                    ページ15に含まれる内容の要旨 
                    
                        15 15 INSTALLATION  CAUTION: The glass panels become very hot while the  Continued appliance is operating. Do not attempt to adjust or clean  the glass doors until the appliance has fully cooled.  INSTALLING OPTIONAL GLASS DOOR  The doors may be removed for replacement or cleaning as follows: ACCESSORY 1. Partially open the door and press up on the upper spring clip with   CAUTION: Use only glass doors certified for use  a screw driver until the outer top pivot pin is free of the clip. with this 
                    
                    ページ16に含まれる内容の要旨 
                    
                        16 9. Push in the knob all the way and hold in. Immediately light  OPERATING FIREPLACE the pilot manually. Continue to hold the control knob in for  about (1) minute after the pilot is lit. Release knob and it will  FOR YOUR SAFETY  pop back up. Pilot should remain lit. If it goes out, repeat  READ BEFORE LIGHTING steps 5 through 9. • If knob does not pop up when released, stop and imme-  WARNING: If you do not follow these instructions  diately call your service technician or gas supplier. exac
                    
                    ページ17に含まれる内容の要旨 
                    
                        17 17 OPERATING FIREPLACE INSPECTING BURNERS  Continued Check pilot flame pattern and burner flame patterns often. OPTIONAL HAND-HELD  PILOT ASSEMBLY REMOTE OPERATION The pilot assembly is factory preset for the proper flame height.  Note: The receiver and hand-held remote control kit must be  Alterations may have occurred during shipping and handling. The  purchased separately (see Accessories, page 27). Follow instal- pilot is located on the back right hand side of the burner. lation instructions
                    
                    ページ18に含まれる内容の要旨 
                    
                        O 18 CLEANING AND SERVICE HINTS MAINTENANCE When Gas Pressure Is Too Low • pilot will not stay lit  WARNING: Installation and repair should be done  • burner will have delayed ignition by a qualified service person. The appliance should be  inspected before each use and at least annually by a  • fireplace will not produce specified heat qualified service person. More frequent cleaning may be  • propane/LP gas supply may be low if using propane/LP gas required due to excessive lint from carpeting, be
                    
                    ページ19に含まれる内容の要旨 
                    
                        19 19 TROUBLESHOOTING Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot will not light 1. No gas supply or shutoff valve is OFF 1. Check to see if you have gas supply 2. Air in gas line 2. Hold regulator control valve in the PI- LOT position for 2 to 3 minut
                    
                    ページ20に含まれる内容の要旨 
                    
                        20 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Spark ignitor will not light pilot after re- 1. Defective ignitor (no spark at elec- 1. Check for spark at the electrode and  peated triggering of red button trode) pilot; if no spark and electrode wire is  properly connected, replace ignitor 2. Defective pilot or misaligned electrode 2. Using a match, light pilot. If pilot lights,  at pilot (spark at electrode) turn off pilot and trigger the red button  again. If pilot lights,