ページ1に含まれる内容の要旨 
                    
                         
 
 
Wall Mounted Mini Split 
 
Heat Pump 
Air Conditioner 
 
 
 
 
OPERATING AND INSTALLATION MANUAL  
Model: KFIHP-09-ID / KFHHP-09-OD 
 
            KFHHP-12-ID / KFHHP-12-OD 
 
 
 
 
 
 
 
 
Indoor Unit. 
 
 
 
Outdoor Unit. 
 
Thank you for selecting Soleus Air. To ensure proper 
operation, please read this manual and keep it for 
future reference.                                                                                                                                                
                    
                    ページ2に含まれる内容の要旨 
                    
                              TABLE OF CONTENTS     STRUCTURE AND OPERATION...……………………..……………………………………….....1-8     Name of Each Part  …………………………………………………………….………..………...……1 The Instructions before Use…………………………………………………………………………2-3  Specifications and Technical Data……………………………….……..……………….…………….4  Remote Control Operation………………………………………………….….…...............………5-6  How to Insert Batteries……………………………………………..………………….………...……7  Operation………………………………………………………………………………………...……8  INSTALLATION...……………………..………………………………………………
                    
                    ページ3に含まれる内容の要旨 
                    
                            Structure and Operation                     ◆Name of Each Part             - 1 -                                                                                                                                                                                                                                                                                                                                                                                                                                
                    
                    ページ4に含まれる内容の要旨 
                    
                                             ◆The Instructions before Use    Warning  ★Grounding: The unit must be properly ★Disconnect the power when the unit is not being  grounded. used for extended periods of time.              ★Don’t attempt to repair the air conditioner by ★If your air conditioner malfunctions,  yourself.  There are no user replaceable parts.  discontinue use and call your authorized dealer.    Please contact your authorized dealer.                  ★Never block the air inlet or outlet of indoor 
                    
                    ページ5に含まれる内容の要旨 
                    
                                             ◆The Instructions before Use    ★Set the room temperature appropriately. ★Adjust the air flow and direction properly.   When the air conditioner is running, you can  press the SWING key on the remote control to  adjust the guide louver and change the  The difference  between indoor  direction of air flow.  and outdoor    temperature  shall be 40 °F.                ★Close all doors & windows for efficient ★To avoid harm to your pets or plants, never  operation. direct the air
                    
                    ページ6に含まれる内容の要旨 
                    
                                             ◆Specification and Technical Data    KFIHP-09-ID KFHHP-12-ID  Model  KFIHP-09-OD KFHHP-12-OD  Function Cool / Heat  Accessory Air Cleaner  Cooling capacity (Btu/h) 9000 12000  Heating capacity (Btu/h) 9500 13000  Power Supply (V) 115V~ 208~230  Frequency (Hz) 60  Cooling/Heating rated current(A) 12/13.6 9/10  Cooling/Heating rated power(W) 1250/1450 1700/1750  Cooling/Heating power input(W) 730/840 1100/1200  3 Recycling air Volume(m /h) 550  Refrigerant and weight(lbs) R410
                    
                    ページ7に含まれる内容の要旨 
                    
                                             ◆Remote Control Operation      Function-Remote control    Note:    • Don't drop the remote control.  • Don't place the remote control in a location exposed to direct sunlight.  • When the unit is restarted after stopped, it will automatically resume its last running mode, and the  outdoor unit will start there after.    MODE Button:      TEMP+ TEMP- Button:    When the unit is    turned on, press this  Under the COOL, DRY,  button. The AUTO,  FAN or HEAT mode,  COOL, DRY, FA
                    
                    ページ8に含まれる内容の要旨 
                    
                                             ◆Remote Control Operation (Continued)              Liquid Crystal Display.    It shows all set contents.  SWING Button:  ON/OFF Button      Press once to have louvers  Press ON.  swing [oscillate]. Press  Press OFF.  twice in one second the  panel light will turn on.   Press twice again and the  light will turn off.  T-ON Button.    When pressing this button  once, enter into T-ON  setting, the icon of T-ON  flash, every press of T-OFF Button  TIME+, the time of T-ON   will 
                    
                    ページ9に含まれる内容の要旨 
                    
                                             ◆How to Insert Batteries      1. Remove the cover from the back of the remote control.  2. Insert the two batteries (Two AAA dry-cell batteries).  3. Re-attach the cover.      NOTE:    • Don’t mix different batteries.  • Remove batteries when not in use for a longtime.  • The batteries can be used for about one year.  • Keep remote at least 3.28 feet from TV’s and other electronic devices.                        When the wireless remote control is lost or broken, please use 
                    
                    ページ10に含まれる内容の要旨 
                    
                                             ◆Operation      The general procedure:  1. Power the unit and a buzzer will sound.  Power/Run indication is red and the air conditioner is waiting  to run.  (Note: Once the air conditioner plugs to power supply or receives the signal of remote control, the  buzzer will send out the desirable sound.)  2. Press ON/OFF button, Power/Run indication is green and shows the running mode (Cooling, Heating,  and Auto), and then the air conditioner starts running.  3. Press MODE butto
                    
                    ページ11に含まれる内容の要旨 
                    
                            Installation                     ◆Installation Location      Indoor Unit    1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room.  2. Install in a location from which the condensation water can be drained out conveniently and that is  permitting easy connection with the outdoor unit.  3. Avoid a location where there is heat source, steam or inflammable gas.  4. Install in a location where it can withstand the full weight and vibration of the u
                    
                    ページ12に含まれる内容の要旨 
                    
                                             ◆Electric Wiring      1. All the electric work must be done according to the wiring diagram.  2. Check for the correct voltage of the unit.  3. Don’t pull the power cord strongly.  4. The air conditioner must be safely grounded!  Grounding wire must be connected to the building and  done by the qualified personnel. In fixed circuit, there must be electricity leakage protection switch of  enough power capacity and air switch with enough space. Air switch (thermal-magnetic bre
                    
                    ページ13に含まれる内容の要旨 
                    
                                             ◆Installation Dimension Diagram        Important Notes     The installation must be done by trained and qualified service personnel.  112.6 inch  212.6 inch           - 11 -                                                                                                                                                                                                                                                                                                                  
                    
                    ページ14に含まれる内容の要旨 
                    
                                             ◆Installation       • Install the rear panel  1. Always mount the rear panel horizontally.   Because the mouth of drainage pipe is at the left  side and the left side of the rear panel is better to  adjust slightly lower.  2. Fix the rear panel on the selected location with  50  50  screws supplied with the unit.  3. Be sure that the rear panel has been fixed firmly  enough to withstand the weight of an adult of    132.3 lbs; furthermore, the weight should be    evenly share
                    
                    ページ15に含まれる内容の要旨 
                    
                                             ◆Installation      4. Connect the Neutral wire of the power connection cables to the “N (1)” terminal of the terminal  board, connect the Signal wire to the “2” terminal, and connect the live wire to the“3”terminal and  connect the grounding wire to the “ ” terminal.  5. Reassemble the wiring cover and tighten the screw.  6. Recover the surface panel.                                                   - 13 -                                                                     
                    
                    ページ16に含まれる内容の要旨 
                    
                              ◆ Install the Indoor Unit      1. When routing the piping and wiring from the left or right side of the indoor unit, cut off the tailings from  the chassis in necessary (shown in Fig.4 (a), (b) and (c)).  (1) Cut off the tailings 1 when routing the wiring only.  (2) Cut off the tailings 1 and tailings 2 (or tailings 1, tailings 2 and tailings 3) when routing both the  wiring and piping.  ①, ②, and ③ in Fig. 4 are the recommended piping.  2. Wrap the piping and wiring and pull them through 
                    
                    ページ17に含まれる内容の要旨 
                    
                                             ◆Install the Outdoor Unit       • Install the connection pipe  1. Align the center of the piping flare with the valve.  2. Screw in the flare nut by hand and then tighten  the nut with spanner and torque wrench refer to  right figure.    Tightening Torque Table    Hex Nut Diameter Tightening Torque  (mm) (N.m)    Φ6 15~20    φ12 50~55    Note: Exceeding tightening torque will                damage the flare nut.          • Electric wiring connection  1. Disassemble the big h
                    
                    ページ18に含まれる内容の要旨 
                    
                                             ◆Install the Outdoor Unit      • Air Purging and Leakage Test  1. Remove the flare nuts of charging end from gas valve.  2. Connect the charging hose in the middle to the vacuum  pump, then Low-pressure (Lo) end should be connected  to charging end of gas valve. (Shown in Fig. 9)  3. Open the vacuum pump to evacuate.  When multi-meter  indicates 1 bar, fully tighten Lo handle of manifold valve  and stop evacuation. Keep it for over 15 minutes to ensure  the pressure is const
                    
                    ページ19に含まれる内容の要旨 
                    
                                             ◆Test Operation and Check after Installation      Test Operation    1. Before Test Operation  (1) Do not switch on power before installation is finished  completely.  (2) Electric wiring must be connected correctly and securely  (3) Cut-off valves of the connection pipes should be opened.  (4) All the impurities such as scraps must be cleared from the  unit.      2. Test Operation Method  (1) Switch on power and press “ON/OFF” button on the remote control to run the air  con
                    
                    ページ20に含まれる内容の要旨 
                    
                            Care and Maintenance                     ◆Care and Maintenance      CAUTION:    Turn power off and pull out the power cord before cleaning air conditioner.   Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can  cause an electric shock.   Volatile Liquid (e.g. thinner or gasoline) will damage the air conditioner.  (So wipe the  units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.)    Clean the front panel (Don’t remove the fro