ページ1に含まれる内容の要旨 
                    
                         
Models 
SG-TTW-09ESE-26 
SG-TTW-09HC-26 
SG-TTW-12HC-26
SG-TTW-12ESEZ-26  
Electronic Through the Wall Air Conditioner 
Operating Instructions                                                                                                                                                                                                                                                                                                                                                                    
                    
                    ページ2に含まれる内容の要旨 
                    
                        Contents IMPORTANT NOTE TO THE OWNER ........................... 1 IMPORTANT NOTE TO THE SERVICER ....................... 1 Unit Features ................................................................ 1 Transportation Damage .............................................. 1 Unpacking The Unit ..................................................... 1 Operating Instructions ................................................. 1 Installation Instructions ..............................................  
                    
                    ページ3に含まれる内容の要旨 
                    
                        Specifications  • Noise level is measured at a distance of 3.28ft away from the front of the unit in cooling mode.  • Power consumption is measured when the fan runs at the highest speed settings.  • These specifications are for reference only. For actual data, please refer to the rating label on the unit.    Model Number SG-TTW-09ESE-26 SG-TTW-09HC-26 SG-TTW-12ESEZ-26 SG-TTW-12HC-26  Power Supply (Ph/V/Hz) 1/115/60 1/230-208/60 1/115/60 1/230-208/60  Dehumidifying Capacity (Pt/Day) 60 60 81.6 8
                    
                    ページ4に含まれる内容の要旨 
                    
                        Operating Instructions  IMPORTANT NOTE TO THE OWNER  This equipment is to be serviced by professionally trained Check the data specification plate and ensure the proper  personnel only. If this equipment is improperly installed,  voltage and current rating for the type of power plug on the  adjusted or altered by an unqualified person, a safety unit is available. DO NOT REMOVE THE GROUNDING  hazard may result.  PRONG FROM THE POWER CORD. See Figure 1 for the  types of acceptable plugs. Do not us
                    
                    ページ5に含まれる内容の要旨 
                    
                        CHASSIS INSTALLATION  WARNING  1. Remove front grille. See Figure A.  To prevent electrical shock, property damage, personal injury, or death, do not remove grounding prong from plug. Follow  Lift up on  all operating instructions.  Filter Handle Installation Instructions  To ensure that the unit operates safely and efficiently, it must  be installed, operated, and maintained according to these  installation and operating instructions and all local codes  and ordinances, or, in their absence, wi
                    
                    ページ6に含まれる内容の要旨 
                    
                        Locking Plate Figure 3  3. Remove shipping pads inside air conditioner next to Figure C  compressor. (See Figure B.)  6. If outlet is on the left side of the unit. route power cord as shown in Figure D.  Remove Power  shipping  Cord pads  Clamp  Figure B 4. Carefully slide the chassis into the sleeve.  Ensure Figure D  that the ground wire is not pinched or in the path of the condenser fan.  5. Loosen locking plate screw and rotate tab with tab behind wall case flange (See Figure C)  then tighte
                    
                    ページ7に含まれる内容の要旨 
                    
                        To replace front grille:  Grille Tab  EXHAUST AIR VENT  Figure 4  AIR DIRECTION:  Horizontal louvers on the front grille let you control the air  Hook the tabs on the front grille even with the tabs on the  direction up and down.  case and snap into place. Replace the screws and filter.  Refer to Page 4, Figure A.  VENT CONTROL AND AIR DIRECTION (See Figure E) The vent control is located behind the front grille on the right  side of the air discharge area. When set at CLOSE only the  air inside 
                    
                    ページ8に含まれる内容の要旨 
                    
                        Remove the front grille to adjust the vertical louvers side-to- Wiring side to direct the air left or right.  Before wiring the unit, please review the following warnings  and cautions.  WARNING  To avoid the risk of electrical shock,  personal injury or death, do not service this unit without first opening all disconnects and/or removing the unit cord set plug from the wall outlet.  WARNING  To avoid the risk of electrical shock,  personal injury, or property damage, do not use an extension cor
                    
                    ページ9に含まれる内容の要旨 
                    
                        Air Conditioner  ELECTRONIC CONTROL OPERATING INSTRUCTIONS  Before you begin, thoroughly familiarize yourself with the control panel and  Features  remote as shown below and all its functions. Then follow the symbol for the  functions you desire. The unit can be controlled by the touch pad alone or with the  remote.  LOWERS  TEMPERATURE DISPLAYS  TEMPERATURE/TIME  OR TIME  RAISES  TEMPERATURE  OR TIME  TURNS UNIT  SETS FAN SPEED  ON OR OFF  SETS MODE  TIMER  SLEEP MODE   LOWERS  TEMPERATURE  DIS
                    
                    ページ10に含まれる内容の要旨 
                    
                        OPERATING THE REMOTE CONTROL    NOTE: Make sure there are no obstructions between the receiver on the A/C and the  remote control. Do not drop or throw the remote control. Do not allow water to get  inside the remote control and do not place the remote control in direct sunlight or a  place where it is very hot.  • Press the SLEEP button to turn SLEEP  mode on or off. SLEEP mode is set to  off automatically. When SLEEP mode is  selected the timer can be adjusted.  SLEEP mode is not available in 
                    
                    ページ11に含まれる内容の要旨 
                    
                        OPERATING THE REMOTE CONTROL    • Press the TIMER button when the unit  is off to set up the Auto-on timer. The  Auto-on time can be set between .5 -  24 hours. The icons “T-ON” and “H”  will flash for 5 seconds. Start select- ing the time using the “+” and “-” but- tons before the icons stop flashing.  The time will increase/decrease in .5  hour increments with each press of  the “+” or “-” buttons.  To cancel the  Auto-on time, manually press the ON/ OFF button to turn the unit on.    • Press 
                    
                    ページ12に含まれる内容の要旨 
                    
                        Air Conditioner  Features  Guide for operation- General operation 1. To power on the unit, press the ON/OFF button. The unit will start to run. (Note: When  it is powered off, the louvers will close automatically.) 2. Press MODE button, select desired running mode, or press COOL or HEAT   mode to enter into the corresponding operation directly. 3. Press the + or - button to set the desired temperature. (It is unnecessary  to set the temp. in AUTO mode.) 4. Press the  FAN button to set fan speed.
                    
                    ページ13に含まれる内容の要旨 
                    
                        Air Conditioner Features (continued) TO TURN UNIT ON: YOU WILL SEE: DO THIS:  PRESS ON/OFF BUTTON TO CHANGE YOU WILL SEE: TEMPERATURE SETTING:  DO THIS:  PRESS TO RAISE PRESS TO LOWER Note: Tap or hold either up(^) or down(v) button until the desired temperature is seen on display. This temperature will be  ° automatically maintained anywhere between 61F (16 ° C) and 86F (30 C) for both cooling and heating modes.    If you want the display to read the actual room temperature, select the Fan Only
                    
                    ページ14に含まれる内容の要旨 
                    
                        Air Conditioner Features  (continued) : T O OPERAT E O N FA N ONLY:  YOU WILL SEE LIGHT ON  DO THIS:  PRESS MODE BUTTON CHOOSE FAN ONLY Note: Use this function only when cooling is not desired but room air circulation is needed. You can choose any fan speed you prefer, EXCEPT AUTO FAN. During this function, the display will show the current room temperature, not the set temperature.  TO USE THE : LIGHT ON YOU WILL SEE ENERGY SAVER FEATURE:  DO THIS:  PRESS MODE BUTTON CHOOSE ENERGY SAVER Note: I
                    
                    ページ15に含まれる内容の要旨 
                    
                        Air Conditioner Features  (continued) HEATING FEATURE (on some models): YOU WILL SEE: DO THIS:  PRESS MODE BUTTON SELECT HEAT Note: This feature can be used with any combination of FAN Speeds, Timer, or Sleep Modes. When in the “Heat” Mode, the  fan will run continuously while heat is needed. The temperature will automatically be maintained anywhere between 61°F  (16°C) and 86°F (30°C). When the set room temperature is reached, the fan will cycle off and on to circulate and sample  the room air.
                    
                    ページ16に含まれる内容の要旨 
                    
                        ADDITIONAL THINGS YOU SHOULD KNOW  Now that you have mastered the operating procedure, here are more features in your control that you should know.  � The Remote Control will operate all the control panel features, follow the same instructions.  � The "Cool "circuit has an automatic 3 minute time delayed start if the unit is turned off  and on quickly. This prevents overheating of the compressor and possible circuit  ! !  breaker tripping. The fan will continue to run during this time.  � The co
                    
                    ページ17に含まれる内容の要旨 
                    
                        WARRANTY    One Year Limited Warranty    Soleus International, Inc. warrants the accompanying Soleus Air Powered by Gree Air Conditioner to be free of defects  in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year  from the date of original retail purchase in the United States.    If the unit exhibits a defect in normal use, Soleus International will, at its option, either repair or replace it, free of  charge within a reasonable tim