Kramer Electronics, Ltd. 
 
 
 
 
 
 
 
 
 
 
 
USER MANUAL 
 
 
Model: 
PL-50 
Power Controller - Monitor 
 
 
                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    ページ2に含まれる内容の要旨 
                    
                        Contents  Contents  1 Introduction 1  2 Getting Started 1  2.1 Quick Start 1  3 Overview 3  3.1 Terminology Used in this User Manual 4  4 Your PL-50 Power Controller - Monitor 4  5 Installing in a Rack 7  6 Connecting the PL-50 Power Controller - Monitor 8  6.1 Connecting the Relays 9  6.2 Controlling the PL-50 via the Ethernet Port 9  6.2.1 Connecting the ETHERNET Port Directly to a PC (Crossover Cable) 9  6.2.2 Connecting via a Straight-Through Cable 10  6.2.3 Configuring the Ethernet Port Ini
                    
                    ページ3に含まれる内容の要旨 
                    
                        Contents  10.7 Instruction Codes 43  Figures  Figure 1: PL-50 Power Controller – Monitor Front Panel 5  Figure 2: PL-50 Power Controller – Monitor (for Europe) Rear Panel 5  Figure 3: PL-50 Power Controller – Monitor (for USA) Rear Panel 5  Figure 4: Connecting the PL-50 8  Figure 5: Relay Wiring 9  Figure 6: Local Area Connection Properties Window 10  Figure 7: Internet Protocol (TCP/IP) Properties Window 10  Figure 8: K-UPLOAD Main Screen 11  Figure 9: Connect Screen 12  Figure 10: Device Prop
                    
                    ページ4に含まれる内容の要旨 
                    
                        Contents  Tables  Table 1: Terminology Used in this User Manual 4  Table 2: PL-50 Power Controller – Monitor Features 6  Table 3: Relay PINOUT 9  Table 4: The Scheduler Screen Features 16  Table 5: The Channel Settings Screen Features 18  Table 6: The Alerts Screen Features 19  Table 7: The Power Measurement Screen Features 21  Table 8: The Power ON/OFF Order Screen Features 22  Table 9: DIP-switch Definitions 27  Table 10: Technical Specifications of the PL-50 35  iii                           
                    
                    ページ5に含まれる内容の要旨 
                    
                        Introduction  1 Introduction  Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been  providing a world of unique, creative, and affordable solutions to the vast  range of problems that confront the video, audio, presentation, and  broadcasting professional on a daily basis. In recent years, we have redesigned  and upgraded most of our line, making the best even better! Our 1,000-plus  1 different models now appear in 11 groups that are clearly defined by  function.  Congratulati
                    
                    ページ6に含まれる内容の要旨 
                    
                        Getting Started      KRAMER:  SIMPLE CREATIVE TECHNOLOGY  2                                                                                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    ページ7に含まれる内容の要旨 
                    
                        Overview  3 Overview  The PL-50 Power Controller Monitor can control up to five power channels at  a total load of 10A. The PL-50, by measuring and then monitoring the  standby and active modes of the connected units, can detect whether a unit is  in the standby mode, the active mode or is disconnected.   Two versions of the PL-50 are available, a European version and a version for  the USA.  The PL-50 features include:  • PRESET LEVEL buttons, for measuring the STANDBY mode and the  ACTIVE mode
                    
                    ページ8に含まれる内容の要旨 
                    
                        Your PL-50 Power Controller - Monitor  3.1 Terminology Used in this User Manual  Table 1 defines some terms that are used in this user manual:  Table 1: Terminology Used in this User Manual  Term Definition  802.3  The standard specification for ETHERNET that is maintained by the Institute of Electrical and  Electronics Engineers (IEEE).  Dynamic Host Configuration Allows the network administrator to distribute IP addresses from a central point and  Protocol (DHCP) automatically send a new IP ad
                    
                    ページ9に含まれる内容の要旨 
                    
                        Your PL-50 Power Controller - Monitor    Figure 1: PL-50 Power Controller – Monitor Front Panel    Figure 2: PL-50 Power Controller – Monitor (for Europe) Rear Panel    Figure 3: PL-50 Power Controller – Monitor (for USA) Rear Panel  5                                                                                                                                                                                                                                                                         
                    
                    ページ10に含まれる内容の要旨 
                    
                        Your PL-50 Power Controller - Monitor  Table 2: PL-50 Power Controller – Monitor Features  # Feature Function  1 IR Receiver Window The red LED lights when receiving signals from the Kramer  Infrared remote control transmitter  2 POWER LED The red LED lights when the main power is ON  3 OUT Channel STANDBY LED The orange LED lights when the channel outlet is in the  (from 1 to 5) standby mode, and blinks when reading the standby level  4 ACTIVE LED The green LED lights when an outlet is connecte
                    
                    ページ11に含まれる内容の要旨 
                    
                        Installing in a Rack  5 Installing in a Rack  This section describes what to do before installing in a rack and how to rack  mount.  Before Installing in a Rack How to Rack Mount To rack-mount a machine: Before installing in a rack, be sure that the  1.  Attach both ear brackets to the  environment is within the recommended range: machine. To do so, remove the  OPERATING TEMPERATURE: 0º to +55ºC (32º to 131ºF) screws from each side of the  STORAGE TEMPERATURE: -45º to +72ºC (-49º to 162ºF) machi
                    
                    ページ12に含まれる内容の要旨 
                    
                        Connecting the PL-50 Power Controller - Monitor  6 Connecting the PL-50 Power Controller - Monitor  1 To connect the PL-50, as illustrated in the example in Figure 4, do the following :  2 1. Connect up to five outlets (from 1 to 5). For example, connect:   OUT 1 to a DVD player   OUT 2 to an LCD display   OUT 4 to a power amplifier with speakers   OUT 5 to a lighting system  2. Set the DIP-switches (see Table 2).  3. Connect an item (for example, an alarm) via the RELAY and/or DIGITAL  CONT
                    
                    ページ13に含まれる内容の要旨 
                    
                        Connecting the PL-50 Power Controller - Monitor  6.1 Connecting the Relays  Figure 5 shows how to connect the relay.  To Alarm   Figure 5: Relay Wiring  On each 3-pole terminal block connector, connect either: C to NC, or C to  NO. Table 3 defines the Relay PINOUT:   Table 3: Relay PINOUT  RELAY PINOUT  C Common  NO Normally Open (relay is open by default and closes for activation)  NC Normally Closed (relay is closed by default and opens for activation)  6.2 Controlling the PL-50 via the Ethern
                    
                    ページ14に含まれる内容の要旨 
                    
                        Connecting the PL-50 Power Controller - Monitor  5. Select the Internet Protocol (TCP/IP) and click the Properties button (see  Figure 6).    Figure 6: Local Area Connection Properties Window  6. Select Use the following IP address, and fill in the details as shown in   Figure 7.  7. Click OK.    Figure 7: Internet Protocol (TCP/IP) Properties Window  6.2.2 Connecting via a Straight-Through Cable  You can connect the ETHERNET of the PL-50 to the Ethernet port on a  network hub or network router,
                    
                    ページ15に含まれる内容の要旨 
                    
                        Connecting the PL-50 Power Controller - Monitor  6.2.3 Configuring the Ethernet Port Initially  To initially configure the Ethernet port, download the K-UPLOAD Ethernet  1 configuration software . Extract the file to a folder and create a shortcut on  your desktop to the file.  Follow these steps to configure the port:  1. Double click the desktop icon  the K-UPLOAD screen appears:    Figure 8: K-UPLOAD Main Screen  2. Click the Connect button.  The Connect screen appears as follows:            
                    
                    ページ16に含まれる内容の要旨 
                    
                        Connecting the PL-50 Power Controller - Monitor    Figure 9: Connect Screen  3. Connect a USB cable from a USB port on the PC to the USB port on the  PL-50 (you can also connect to the PC via the Ethernet or a serial connector).  4. Check USB as the connection method and select the com port from the USB  drop down list.  5. Click Connect.  The K-UPLOAD screen appears.    Figure 10: Device Properties Screen  6. If required, make changes and click Save. If not, click Exit.  KRAMER:  SIMPLE CREATIV
                    
                    ページ17に含まれる内容の要旨 
                    
                        Connecting the PL-50 Power Controller - Monitor  6.3 Controlling via the Embedded Web Pages  The embedded Web page can be used to remotely operate the PL-50 via the  Ethernet (see section  6.2).   6.3.1 Setting the Embedded Web Page  Before you use the embedded Web pages to control the PL-50 via the  Ethernet, check that the Java™ software is installed on your computer. If not,  download it from: www.java.com.  A description of each Web page appears if you hover with your mouse over the  questio
                    
                    ページ18に含まれる内容の要旨 
                    
                        Connecting the PL-50 Power Controller - Monitor   Check that Java and JavaScript is enabled in your browser. The following  window appears:    Figure 13: Running the Application  3. Click Run.  Figure 14).  The PL-50 front panel is displayed on your screen (see  The Web embedded screens let you control the PL-50 via the Ethernet. The  menu appears on the left side of the screen.  The web embedded pages include a security system (see Section 6 .3.8.1). If  the security system is disabled (for exa
                    
                    ページ19に含まれる内容の要旨 
                    
                        Connecting the PL-50 Power Controller - Monitor  6.3.2 The Panel Screen  The Panel screen lets you select one or more channels in order to read the  Standby or Active values and turn the power outlet ON/OFF:    Figure 14: HOME Embedded Web Page   The connection icon on the top right screen indicates whether the machine is  connected to your PC  or not .  Click the on-screen channel buttons:  1 2 3 4 5   Figure 15: Selecting a Channel  Each channel button includes red and green indicators. If the
                    
                    ページ20に含まれる内容の要旨 
                    
                        Connecting the PL-50 Power Controller - Monitor  6.3.3 The Scheduler Screen  The Scheduler screen lets you schedule the operation of the outlets on a  weekly basis. Figure 16 and Table 4 define the Scheduler screen:    Figure 16: The Scheduler Screen   Table 4: The Scheduler Screen Features  Feature Function  DATE/TIME SETTINGS Set the current date and time  Click Read to read the machine settings  Click Submit to accept the date and time settings  Click From PC to acquire the date and time from