ページ1に含まれる内容の要旨 
                    
                        User Manual 
 
 
MTM400 
MPEG Transport Stream Monitor 
071-1224-04  
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - FAX 781.665.0780 - TestEquipmentDepot.com                                                                                                                                                                                                                                                                                                                      
                    
                    ページ2に含まれる内容の要旨 
                    
                          Table of Contents  General Safety Summary ...................................................................................... vii  Service Safety Summary.........................................................................................ix  Preface.....................................................................................................................xi  Related Material.................................................................................................... xii 
                    
                    ページ3に含まれる内容の要旨 
                    
                        Table of Contents  PIDs Screen.........................................................................................................3-34  PID Groups Screen..............................................................................................3-41  PCR Jitter Screen ................................................................................................3-48  SFN Screen..........................................................................................................3-56  
                    
                    ページ4に含まれる内容の要旨 
                    
                         Table of Contents  Appendices  Appendix A: Network Installation ................................................................... A-1  MAC Address ...................................................................................................... A-2  IP Address............................................................................................................ A-3  Resetting the IP Address...................................................................................... A-3  Ne
                    
                    ページ5に含まれる内容の要旨 
                    
                        Table of Contents  List of Figures  Figure 1-1: MTM400 connectors (shown with QPSK interface)....................................... 1-9  Figure 1-2: Logging on .................................................................................................... 1-15  Figure 1-3: Hotspot view ................................................................................................. 1-16  Figure 1-4: Summary view ..............................................................................
                    
                    ページ6に含まれる内容の要旨 
                    
                         Table of Contents  Figure 3-25: ATSC SI Tables dialog................................................................................3-63  Figure 3-26: ISDB-T SI Tables dialog.............................................................................3-64  Figure 3-27: SI Tables view - Tear off view ....................................................................3-66  Figure 3-28: Stream view - Template...............................................................................3-69  Fig
                    
                    ページ7に含まれる内容の要旨 
                    
                        Table of Contents  List of Tables  Table 1-1: Standard MTM400 deliverables ....................................................................... 1-2  Table 1-2: MTM400 options (continued) .......................................................................... 1-2  Table 1-3: MTM400 power cord options........................................................................... 1-3  Table 1-4: MTM400 field upgrade kits.............................................................................
                    
                    ページ8に含まれる内容の要旨 
                    
                          General Safety Summary  Review the following safety precautions to avoid injury and prevent damage to this product or any  products connected to it. To avoid potential hazards, use this product only as specified.  Only qualified personnel should perform service procedures.  To Avoid Fire or Personal Injury  Use Proper Power Cord. Use only the power cord specified for this product and certified for the  country of use.  Ground the Product. This product is grounded through the grounding conducto
                    
                    ページ9に含まれる内容の要旨 
                    
                        General Safety Summary  Symbols and Terms  Terms in this Manual. These terms may appear in this manual:  WARNING. Warning statements identify conditions or practices that could result in  injury or loss of life.    CAUTION. Caution statements identify conditions or practices that could result in  damage to this product or other property.  Terms on the Product. These terms may appear on the product:  DANGER indicates an injury hazard immediately accessible as you read the  marking.  WARNING indic
                    
                    ページ10に含まれる内容の要旨 
                    
                          Service Safety Summary  Only qualified personnel should perform service procedures. Read this Service  Safety Summary and the General Safety Summary before performing any service  procedures.  Do Not Service Alone. Do not perform internal service or adjustments of this  product unless another person capable of rendering first aid and resuscitation is  present.  Disconnect Power. To avoid electric shock, switch off the instrument power, then  disconnect the power cord from the mains power.  Use
                    
                    ページ11に含まれる内容の要旨 
                    
                          Preface  This manual describes the functions and use of the Tektronix MTM400 MPEG  Transport Stream Monitor. The manual is organized into the following sections:   Getting Started   An overview of the MTM400, installation instructions, starting the unit, and  the remote user interface.   Operating Basics   A basic guide to the MTM400 user interface(s).   Reference   A complete reference to all of the MTM400 features as accessed through the  user interface.   Appendix A: Networking  Details on 
                    
                    ページ12に含まれる内容の要旨 
                    
                        Preface    Related Material  Additional documentation, such as Read Me files, may be included on the  installation disks.  The following URLs access the Web sites for the standards organizations listed  (the URLs listed were valid at the time of writing):   MPEG-2 standards (International Organization for Standards)  http://www.iso.ch/   DVB standards (European Technical Standards Institute)  http://www.etsi.org/   ATSC standards (Advanced Television Systems Committee)  http://www.atsc.org/   IS
                    
                    ページ13に含まれる内容の要旨 
                    
                         Preface  Manual Conventions  Naming conventions for the interface elements are based on standard Windows  naming conventions. Naming conventions for MPEG-2, ATSC, and DVB  structures follow the conventions derived from the standards organizations listed  on the previous page. In addition, the following formatting conventions apply to  this manual:   Mono-spaced text can indicate the following:   Text you enter from a keyboard  Example: Enter the network identity (http://TSMonitor01)   Character
                    
                    ページ14に含まれる内容の要旨 
                    
                          Getting Started                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   
                    
                    ページ15に含まれる内容の要旨 
                    
                          Getting Started  This section provides details of installing and powering up the Tektronix MTM400  MPEG Transport Stream Monitor.  Overview  The MTM400 is a single-stream, extended-confidence, MPEG-2 protocol,  monitoring device. It is used to monitor a single transport stream in MPEG-2,  DVB, ISDB and ATSC environments. The MTM400 is a rack-mounted device.  The basic MTM400 provides confidence monitoring by making key measurements  and comparing them with preset parameters; inconsistencies ca
                    
                    ページ16に含まれる内容の要旨 
                    
                        Getting Started  Accessories  The tables in this section list the standard and optional accessories available for the  MTM400 MPEG Transport Stream Monitor.  Standard   Table 1-1 lists the standard accessories that are shipped with the MTM400.  Table 1-1: Standard MTM400 deliverables  Nomenclature Description Deliverables  MTM400 Single stream MPEG 1RU Chassis fitted with Transport Stream  Transport Stream Monitor; Processor Card  packaged in one rack unit User Manual (English, L0 / Japanese, L5
                    
                    ページ17に含まれる内容の要旨 
                    
                         Getting Started  Table 1-2: MTM400 options (continued)  Nomenclature Description Deliverables  Opt. QP QPSK (L-Band) Interface QPSK Interface Card with  associated cabling  Opt. CF COFDM Interface COFDM Interface Card with  associated cabling  Opt. VS 8VSB Interface 8VSB Interface Card with  associated cabling  Opt. EP 8PSK Interface 8PSK Interface Card with  associated cabling    Table 1-3: MTM400 power cord options  Nomenclature Description  A0 North America Power  A1 Universal Euro Power  A2
                    
                    ページ18に含まれる内容の要旨 
                    
                        Getting Started  Field Upgrade Kits   Field upgrade kits contain hardware and software that can be installed by a user.  Table 1-4 lists the Field Upgrade kits that are available for the MTM400.  Table 1-4: MTM400 field upgrade kits  Product Option Description  MTM4UP     01 Field upgrade kit to add Recording Capability   02 Field upgrade kit to add Transport Stream Service Information  Analysis (PSI/SI/PSIP/ISDB structure view and repetition  graphs)   03 Field upgrade kit to add Template Testi
                    
                    ページ19に含まれる内容の要旨 
                    
                         Getting Started  Licensing   Options and upgrades are enabled using a License Key. A License Key is an  encrypted code that unlocks and enables functions that have been installed on the  Real-Time Monitoring (RTM) device. Using this method, upgrading an RTM  device may simply require the entry of a new License Key.  For new RTM devices, the appropriate License Key is applied during production.  However, it is also supplied as part of the product documentation.  When field upgrade options are in
                    
                    ページ20に含まれる内容の要旨 
                    
                        Getting Started  Table 1-5 (parts 1 and 2) summarizes the available streams options:  Table 1-5: MTM400 options summary (part 1 of 2)    Feature Default * Opt. 01 Opt. 02 Opt. 03  Recording SI Template  Capability Analysis Testing  SFN           TMCC       PCR OJ, DR and FO testing       SI View       SI Graphs       PID and program bit rate limit testing       PID Groups  PID variability           Templates      Template tree view   Scheduling           Recording       PCR graphs       Service