ページ1に含まれる内容の要旨 
                    
                        Summary 
 
 
1 INSTRUCTIONS FOR SAFE AND PROPER USE_______________ 20 
2 POSITIONING OF THE HOB _______________________________ 22 
3 ADJUSTMENT TO DIFFERENT TYPES OF GAS _______________ 28 
4 FINAL OPERATIONS_____________________________________ 30 
5 USING THE HOB ________________________________________ 31 
6 CLEANING AND MAINTENANCE ___________________________ 33 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE 
IDENTIFICATION SYMBOLS APPEAR ON 
                    
                    ページ2に含まれる内容の要旨 
                    
                        Introduction      1 INSTRUCTIONS FOR SAFE AND PROPER USE  THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND  THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE  PLACE FOR THE WHOLE WORKING LIFE OF THE HOB. WE ADVISE    READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE  USING THE HOB. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED.  INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN  ACCORDANCE WITH THE REGULATIONS IN FORCE.  THIS APPLIANCE IS  INTENDED FOR FOR DOMESTIC US
                    
                    ページ3に含まれる内容の要旨 
                    
                        Introduction      THE APPLIANCE DATA PLATE, WITH TECHNICAL DATA, REGISTRATION  NUMBER AND BRAND NAME, IS POSITIONED AT A VISIBLE POINT UNDER    THE SAFETY COVER.   THE DATA PLATE ON THE PROTECTIVE COVER MUST NEVER BE  REMOVED.  DO NOT PUT PANS WITHOUT PERFECTLY PERFECTLY SMOOTH AND FLAT  BOTTOMS ON THE HOB PANSTAND GRIDS.        DO NOT USE COOKING RECEPTACLES THAT EXTEND BEYOND THE  OUTSIDE PERIMETER OF THE HOB.        THE APPLIANCE IS DESIGNED FOR USE BY ADULTS. DO NOT ALLOW  CHILDREN TO GO NEA
                    
                    ページ4に含まれる内容の要旨 
                    
                            Instructions for the installer    2 POSITIONING OF THE HOB  The following operation requires building and/or carpentry work so must  be carried out by a competent tradesman.  Installation can be carried out on various materials such as masonry,  metal, solid wood or plastic laminated wood, as long as they are heat-   resistant (T 90°C).  2.1 Attachment to support structure, traditional built-in model  Create an opening with the dimensions shown  in the figure in the work surface, observing a
                    
                    ページ5に含まれる内容の要旨 
                    
                            Instructions for the installer      2.2 Attachment to support structure, flush-mounting model   Create an opening with the dimensions  shown in the figure in the work surface,  observing a minimum distance of  50 mm  from the rear edge.  The lower part of the protective cover  must be fully accessible when the  appliance is installed. This appliance can  be installed next to walls that are higher  than the work surface, as long as the  distance "X" is kept, as shown in the  1)  figure, to av
                    
                    ページ6に含まれる内容の要旨 
                    
                            Instructions for the installer      Important: Other types of installation will only be possible under the manufacturer's supervision.         Overall dimensions: location of gas and electrical connection points (all  measures in mm).      Caution: surface temperature underneath may exceed 125 degrees C.  To avoid a hazard, under-bench access must be restricted.  Refer to installation instruction    IMPORTANT: when installing the appliance above a cupboard, a dividing  shelf, as shown above,
                    
                    ページ7に含まれる内容の要旨 
                    
                            Instructions for the installer      2.3 Electrical connection  Make sure that the voltage and capacity of the power supply cable conform    to the data shown on the plate located under the protective cover. Do not  remove this plate for any reason.  The power supply cable plug and the wall socket must be of the same type  and conform to the current electrical system regulations.  Check that the  power line is adequately earthed.    On the power line, install an all-pole disconnect switch wit
                    
                    ページ8に含まれる内容の要旨 
                    
                            Instructions for the installer    2.4 Ventilation requirements  The appliance may be installed only in rooms with permanent ventilation,  as required by standards regolations in force. The room in which the  appliance is installed must have sufficient air flow to satisfy the    requirements of normal gas combustion and of necessary air exchange    in the room. The air intakes, protected by grills, must be appropriately  sized and placed so as not to be blocked in any way.   The room must be 
                    
                    ページ9に含まれる内容の要旨 
                    
                            Instructions for the installer      2.6 Gas connection  Connection to the gas mains may be made with a rigid copper pipe  or  with a flexible pipe  conforming to the provisions defined by standard  regolations in force.   After connection operations, check for leaks using a soapy solution.   The hob has been inspected for G20 natural gas (2H) at a pressure of 20  mbar. For use with other types of gas, see chapter “3. ADJUSTMENT TO  DIFFERENT TYPES OF GAS. The hose connection at the rear of t
                    
                    ページ10に含まれる内容の要旨 
                    
                            Instructions for the installer      3 ADJUSTMENT TO DIFFERENT TYPES OF GAS     Before performing any cleaning or maintenance work, unplug the  appliance from the mains.        The hob is set for natural gas G20 (2H)  at a pressure of 20 mbar.  In the     case of functioning with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the  nozzles, proceed as described below.        3.1 Replacement of nozzles on the hob      1. Remove th
                    
                    ページ11に含まれる内容の要旨 
                    
                            Instructions for the installer        3.2 Burner and nozzle characteristics table   Rated   Burner heating LPG – G30/G31  30/37 mbar  capacity  (kW)    Nozzle By-pass Reduced Flow rate Flow rate  diameter mm flow rate g/h G30 g/h G31  1/100 mm 1/100 (W)  Auxiliary (1) 1.05 50 30 * 27/28 ** 400 76 75  Semi rapid (2) 1.75 65 33 * 32/33 ** 500 127 125  Ultra Rapid (3) 4.0 100 63 * 63/65 ** 1600 291 286  */**: diameters marked * and ** must be fitted respectively on valves marked * and  **shown 
                    
                    ページ12に含まれる内容の要旨 
                    
                            Instructions for the installer      4 FINAL OPERATIONS  After carrying out the above adjustments, remount in reverse order to the  instructions given in paragraph “3.1 Replacement of nozzles on the hob”.       After having regulated the device with gas other than the one tested,  replace the label located on the guard with the one that corresponds to  the new gas.    The label is available from your nearest Authorised Assistance Centre.       4.1 Regulation of minimum for town gas and natura
                    
                    ページ13に含まれる内容の要旨 
                    
                            Instructions for the user        5 USING THE HOB    5.1 Ignition of the burners  Before turning on the burners, make sure that the flame-spreader crowns    and respective caps are properly fitted in their housings. Ensure the  flame-spreader holes A are aligned with the ignition plugs and the    thermocouples.       Panstand grid B, available upon request, is intended for use with woks    (Chinese pans).  To prevent damage to the worktop, the hob is equipped with a raised grid   C: installs 
                    
                    ページ14に含まれる内容の要旨 
                    
                            Instructions for the user    5.2 Practical advice for using the burners  For better use of the burners and lower gas consumption, use covered  cooking receptacles that have a flat, smooth bottom and are proportional  in size to the burner to prevent the flame from licking the sides (see  paragraph “5.3 Diameter of receptacles”). When water reaches boiling  point, lower the flame so that it does not boil over.     To avoid burns or damage to the worktop, all receptacles or griddle  plates mus
                    
                    ページ15に含まれる内容の要旨 
                    
                            Instructions for the user        6 CLEANING AND MAINTENANCE    Before any intervention, disconnect the appliance from the mains.      Never use a steam jet to clean the appliance.      6.1 Cleaning the stainless steel    To keep stainless steel in good condition it should be cleaned regularly  after use. Let it cool first.    6.1.1 Routine daily cleaning  To clean and preserve the stainless steel surfaces, always use only  specific products that do not contain abrasives or chlorine-based aci
                    
                    ページ16に含まれる内容の要旨 
                    
                            Instructions for the user         In models with central pan stand, fit this piece, taking care that its centre is    perfectly aligned with the centre of the burner    34