Summary of the content on the page No. 1 
                    
                        14423-2 / 14423-4 / 14423-8
UltrasoUnd Pocket doPPler
User ManUal
Important: do not use the Pocket doppler 
without first reading and understanding this 
manual! save this manual for future use.
	 Federal	Law	(USA)	restricts	this	device	to	sale	
by	or	on	the	order	of	a	physician.	This	product	
should	not	be	used	unless	the	operator	has	
been	instructed	by	a	qualified	healthcare	
professional.
14423-INS-LAB-RevE13                                                                                    
                    
                    Summary of the content on the page No. 2 
                    
                        Contents 1	 Intr oduCtIon	 ......................................................................... 3 Intended	use	of	thIs	devICe 	 ........................................ 3 InCl uded	fea tures	 .......................................................... 3 optIon al	a CCessorIes	 ................................................... 4 2	 safety	Informa tIon.............................................................. 5 safety	preCaut Ions	 ....................................................... 
                    
                    Summary of the content on the page No. 3 
                    
                        1	 Intr oduCtIon This user manual contains important information and  safety precautions for the Grafco Ultrasound Pocket  Doppler. Before using the Pocket Doppler, please read and  understand this entire user manual. Take special note of all  safety precautions that begin “WARNING” and “CAUTION”.  Save this user manual for future reference. Info: The most current version of this manual can be  found at www.grahamfield.com Intended	use	of	thIs	devICe The Grafco Ultrasound Pocket Doppler is inten
                    
                    Summary of the content on the page No. 4 
                    
                        optIon al	a CCessorIes The following accessories for use with the Grafco  Ultrasonic Pocket Doppler are available from your  GF Health Products, Inc. authorized distributor or  www.grahamfield.com. Item	no. 	 pr oduct	description 4001GF Coupling Gel, case of 12  0.25 liter bottles 4002GF Coupling Gel, 5 liter bottle 14423-2P 2.0 MHz Waterproof Probe 14423-4P 4.0 MHz Waterproof Vascular Probe 14423-8P 8.0 MHz Waterproof Vascular Probe 14423-INS-LAB-RevE13	 4                                       
                    
                    Summary of the content on the page No. 5 
                    
                        2	 safety	Info rma tIon saf ety	guidance This unit has internally Type B protection means that this  powered equipment, product is in accordance with  and the degree of shock permitted leakage currents and  protection is type B. dielectric strengths of IEC 60601-1. safety	preCaut Ions The safety statements presented in this chapter refer  to the basic safety information that the operator of the  Pocket Doppler shall pay attention to and abide by.  There are additional safety statements in other 
                    
                    Summary of the content on the page No. 6 
                    
                        WarnIngs 	 W ARNING:	Federal	Law	(USA)	restricts	this	device	to	 sale	by	or	on	the	order	of	a	physician.	This	product	 should	not	be	used	unless	the	operator	has	been	 instructed	by	a	qualified	healthcare	professional. 	 W ARNING:	Do	not	use	the	Grafco	Pocket	Doppler	in	 a	flammable	atmosphere	where	concentrations	of	 flammable	anesthetics	or	other	materials	may	occur . 	 W ARNING:	Do	not	expose	batteries	to	heat. 	 W ARNING:	Do	not	attempt	to	charge	alkaline	 batteries;	they	may	leak	or	catch	o
                    
                    Summary of the content on the page No. 7 
                    
                        	 W ARNING:	Use	only	probes	provided	by	GF	Health	 Products,	Inc.	intended	to	be	used	with	the	Grafco	 Pocket	Doppler . 	 W ARNING:	Do	not	stretch	the	probe	cable	further	 than	6.5	feet	(2	meters). 	 W ARNING:	Electromagnetic	Interference:	Before	 operation,	ensure	that	the	environment	in	which	the	 device	is	operated	is	not	subject	to	any	source	of	 strong	electromagnetic	interference,	such	as	radio	 transmitters,	mobile	telephones,	etc. 	 W ARNING:	The	following	safety	checks/tests	must	 be	pe
                    
                    Summary of the content on the page No. 8 
                    
                        not ICes s	 NOTICE:	The	main	unit	of	the	Grafco	Pocket	Doppler	 is	designed	for	continuous	normal	operation.	Do	not	 immerse	or	submerge	in	any	liquid. s	 NOTICE:	Keep	the	Pocket	Doppler	and	its	 environment	clean	and	dust-free.	Protect	the	 device	from	vibration,	corrosive	medicine,	and	high	 temperatures. s	 NOTICE:	Do	not	use	high-temperature	sterilizing	 process,	low	temperature	steam,	E-beam,	or	 gamma	radiation	sterilization	on	this	device	or	its	 accessories. s	 NOTICE:	If	the	Pocket	Dopp
                    
                    Summary of the content on the page No. 9 
                    
                        symbols Attention: Refer to accompanying documents (this manual).  This item is compliant with Medical Device Directive 93/42/ EEC of June 14, 1993, a directive of the European Economic  Community. This symbol consisting of two parts, see below.   Indicates that the equipment should be disposed of according    to local regulation for separate collection after its useful life.  Do not dispose of this device with household waste. Indicates that the equipment is put on the market after 13    August
                    
                    Summary of the content on the page No. 10 
                    
                        3	 handlIng gf	heal th	pr oduCts,	InC .	freIght	polICy f or	y our	pr otection,	r ead	car efull y The carrier accepted this merchandise “in good condition”  and is responsible for safe delivery. Before signing the  freight bill, inspect the shipment carefully for damage or  missing pieces. a ppar ent	loss	or	dama ge Should visual inspection show loss or damage, this MUST  be noted on the freight bill and signed by the carrier's  agent. Failure to do so may result in the carrier failing to  honor 
                    
                    Summary of the content on the page No. 11 
                    
                        Inspection Check the Pocket Doppler for nicks, dents, scratches,  mechanical or other damage. Check all the cables and  accessories.  st ora ge Store the repackaged Pocket Doppler in a dry area. s	 NOTICE:	Ensure	that	the	temperature	at	the	Pocket	 Doppler's	location	during	storage	does	not	fall	below	 -4°F	(-20°C)	or	exceed	131°F	(55°C). s	 NOTICE:	Ensure	that	relative	humidity	at	the	Pocket	 Doppler's	location	during	storage	does	not	exceed	 93%. 14423-INS-LAB-RevE13	 11                       
                    
                    Summary of the content on the page No. 12 
                    
                        4	 ul trasound	poCket	doppler	 and	a CCessorIes appearanCe	and	fea tures The following figures illustrate the Pocket Doppler with  the 2.0 MHz waterproof probe, and accompanying tables  describe labeled features. f r ont	p anel Display Panel POWER Button Probe Speaker Probe Socket f ea tur e function display	 Displays system info p anel System status The system status LED is at the left bottom  corner of the display panel. Please see  LED the following table for significance of LED  indicators. 
                    
                    Summary of the content on the page No. 13 
                    
                        speak er The built-in speaker makes the fetal sounds audible p ower 	 Turns the Ultrasound Pocket Doppler ON or  button OFF  pr obe	 The probe connects here to the Ultrasound Pocket Doppler soc k et Jack definition 1 Power Supply 2 Signal 3 Probe Coding 1 4 Probe Coding 2 5 Probe Coding 3 6 (Shell) GND 14423-INS-LAB-RevE13	 13                                                                                                                                                                            
                    
                    Summary of the content on the page No. 14 
                    
                        r ear	p anel Probe Frame Battery Compartment Probe Socket f ea tur e function ba tter y	 Opens to install/replace battery Compar tment pr obe	f r ame Stores probe when not in use 14423-INS-LAB-RevE13	 14                                                                                                                                                                                                                                                                                                         
                    
                    Summary of the content on the page No. 15 
                    
                        t op	p anel Earphone Socket f ea tur e function soc k et name pictur e function Charge Not used Socket Earphone Connect earphone Socket Signal 1 GND Interface 2 Signal 3 Signal 4 Signal 5 Signal W ar ning Refer to accompanying documents  (this user manual) W ARNING:	 Accessory	equipment	connected	to	 the	analog	and	digital	interfaces	must	be	certified	 according	to	the	respective	IEC	standards	(e.g.	IEC	 950	for	data	processing	equipment	and	IEC	60601-1	 for	medical	equipment).	Furthermore	all	c
                    
                    Summary of the content on the page No. 16 
                    
                        left	p anel V olume Contr ol f ea tur e function v olume	Contr ol Adjust Increase volume:  volume Rotate volume knob  clockwise Decrease volume:  Rotate volume knob  counter-clockwise mode	button Not used st ar t/st op	button reC/pla y	button 14423-INS-LAB-RevE13	 16                                                                                                                                                                                                                                         
                    
                    Summary of the content on the page No. 17 
                    
                        poCket	doppler	Wa terpr oof	pr obes The 2.0 MHz, 4.0 MHz and 8.0 MHz waterproof probes  connect to the main unit of the Grafco Pocket Doppler via  the probe socket. The following table lists and describes  the main information on each probe's label in order of  appearance: p oc k et	doppler	W a ter pr oof 	pr obe	la bel	t a ble pictur e	 of 	p r obe   pr obe	la bel	 2.0	mhz	 4.0	mhz	 8.0	mhz	 t ext W a ter pr oof 	 W a ter pr oof 	 W a ter pr oof 	 pr obe v ascular	 v ascular	 pr obe	* pr obe	* 
                    
                    Summary of the content on the page No. 18 
                    
                        5	 setup Inst all I ng 	 or	repla CIng 	 the	b a tter y 	 W ARNING:	Ensure	that	Pocket	Doppler	power	is	off	 before	replacing	the	battery . 	 W ARNING:	Install/replace	the	battery	at	least	6	feet	 (1.5	meters)	from	the	patient. 	 W ARNING:	Use	only	1.5V	alkaline	battery	(AA,	LR6)	or	 Ni-MH	1.2V	rechargeable	battery	in	this	device. battery cover battery installation 1. Open the battery compartment. Turn the Pocket  Doppler upside down. Hold the main unit with one  hand; press with thumb of other 
                    
                    Summary of the content on the page No. 19 
                    
                        s	 NOTICE:	Keep	the	battery	away	from	objects	or	 materials	with	static	electric	charges. s	 NOTICE:	If	the	 battery	terminals	become	dirty ,	wipe	 them	with	a	clean,	dry	cloth	before	using	the	Pocket	 Doppler . s	 NOTICE:	Batteries	have	life	cycles.	If	the	battery	use	 time	shortens	noticeably ,	the	battery's	life	cycle	is	 over .	Replace	the	old	battery	with	a	new	one	of	the	 same	size	and	type.	Use	only	batteries	recommended	 by	GF	Health	Products,	Inc. s	 NOTICE:	Remove	a	battery	whose	life	
                    
                    Summary of the content on the page No. 20 
                    
                        6	 opera tIon pr obe	opera tIon r emo ving	the	pr obe	fr om	the	p oc k et	doppler s	 NOTICE:	Do	not	drag	or	drop	the	probe.	Do	not	 disconnect	the	probe	from	the	Pocket	Doppler .	           1. The probe is stored  in the Pocket Doppler  probe frame. Hold the  Pocket Doppler main  unit with one hand and  hold the top of the probe  with the other hand. 2. Gently remove the top  of the probe from the  Pocket Doppler probe  frame. 3. Remove the entire  probe from the Pocket  Doppler probe frame. pla