Summary of the content on the page No. 1 
                    
                        User Guide
P/N 9310 1015 0002F    rev. 1.0
© 2007 Aviom, Inc.                                                                                                                                                                                                                                                                                                                                                                                                                                                       
                    
                    Summary of the content on the page No. 2 
                    
                        Certifications ETL/cETL Listed    EMC:  EN 55103-1, EN 55103-2, SAA AS/NZS 1053 Conforms to: IEC 60065, EN 60065, UL 60065 Certified to: CAN/CSA E60065, KETI RoHS Status: RoHS compliant  Notice of Rights All rights reserved. No part of this document may be reproduced or  transmitted in any form or by any means—electronic, mechanical,  photocopy, recording, or otherwise—without written permission of  Aviom, Inc.  Trademarks  Aviom and the Aviom logo are trademarks of Aviom, Inc.    A-Net and the 
                    
                    Summary of the content on the page No. 3 
                    
                        WARNING! ! NO USER SERVICEABLE PARTS INSIDE    REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY • To reduce the risk of fire or electrical shock, do  not expose this product to rain or other types of  moisture. • Operating Temperature: 10˚C to 50˚C (50˚F to 122˚F) CAUTION WARNING! Risk of electric shock! To reduce the risk of fire or  Do Not Open electric shock do not expose  AVIS:    Risque de choc electrique! this product to rain or moisture.  Ne pas ouvrir CAUTION: • Using any audio system
                    
                    Summary of the content on the page No. 4 
                    
                        Important Safety Instructions 1. Read these instructions. 2. Keep these instructions 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance  with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat  registers, stoves, or other apparatus (including amplifiers) that  produce heat. 9. Do not defeat the safety purpose of the 
                    
                    Summary of the content on the page No. 5 
                    
                        Warranty Information Please record the following information for future reference: Your Authorized Aviom Dealer: Name:     Address:    Phone:   Serial Number of Your Aviom Product:    Date of Purchase:   Your Authorized Aviom Dealer is your primary source for service  and support. The information recorded above will be helpful in  communicating with your Authorized Aviom Dealer should you need to  contact Aviom Customer Service. If you have any questions concerning  the use of this unit, please 
                    
                    Summary of the content on the page No. 6 
                    
                        Aviom, Inc. Limited Warranty Aviom, Inc. warrants this product against defects in materials and workmanship  for a period of one year from the date of the original retail purchase.  This warranty does not apply if the equipment has been damaged due to  misuse, abuse, accident, or problems with electrical power. The warranty also  does not apply if the product has been modified in any way, or if the product  serial number has been damaged, modified, or removed.  If a defect is discovered, first w
                    
                    Summary of the content on the page No. 7 
                    
                        Table of Con Ten Ts Warranty Information . . . . . . . . . . . . . . . . . . . . v Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . 1 The EtherCon Connector . . . . . . . . . . . . . . . . 1 The SFP Module  . . . . . . . . . . . . . . . . . . . . 2 The LC Connector. . . . . . . . . . . . . . . . . . . . 2 Cat-5e . . . . . . . . . . . . . . . . . . . . . . . . . 3 Firmware Update . . . . . . . . . . . . . . . . . . . . 3 Abou
                    
                    Summary of the content on the page No. 8 
                    
                        viii                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                
                    
                    Summary of the content on the page No. 9 
                    
                        Welcome This User Guide is designed to familiarize you with the features and  functions of your new Pro64™ product. In developing the Aviom  Pro64 Series product line, we have made every effort to make the user  interface as easy to use and understand as possible. We encourage you  to read the manual completely, as some of the powerful features of your  new product may not be immediately apparent.  This document is a combined User Guide for the MH10 and MH10f  Merger Hubs, which have many featur
                    
                    Summary of the content on the page No. 10 
                    
                        The locking EtherCon connector is similar to an XLR plug, the kind  commonly used on microphone cables. Insert an EtherCon-equipped  cable into the jack until it clicks and locks in place. To remove the cable,  press on the metal release tab at the top of the panel-mounted EtherCon  jack and pull the connector outward.  The SFP Module  The MH10f Merger Hub ships with two 100 Mbps SFP format fiber optic  ports (9 and 10) which allow the user to connect optional single-mode  or multi-mode fiber op
                    
                    Summary of the content on the page No. 11 
                    
                        duplex connectors with the MH10f to avoid transmit/receive errors  caused by the removal of individual fiber cables.   A simplex LC connector (left) and a duplex connector (right).  Cat-5e All Cat-5e connections between A-Net devices should use Unshielded  Twisted Pair (UTP) cable. The cable can be of the stranded or solid type;  solid wire performs better over long distances while stranded wire is  more flexible and easier to manipulate and therefore easier to work  with in a performance situat
                    
                    Summary of the content on the page No. 12 
                    
                        About A-Net   Aviom’s A-Net® is the only networking technology conceived, designed,  and optimized for managing and distributing audio using ordinary  Cat-5e cables. As implemented in the Pro64™ Series products, A-Net  can transmit up to 128 channels of uncompressed 24-bit audio with the  reliability and fidelity of analog, and the power and flexibility of a true  digital network.  Pro64 A-Net allows variable sample rates in three ranges, from 44.1kHz±  to 192kHz±, with ultra-low latency, jitter
                    
                    Summary of the content on the page No. 13 
                    
                        Clocking  The Pro64 network offers the most flexible clocking and synchronization  options in the industry. Pro64 devices support three ranges of variable  sample rates, from 44.1/48kHz± to 192kHz±. Because no sample rate  converters are used, audio transmission is kept fast and clean, eliminating  the audio artifacts and signal degradation inherent to sample rate  conversion—even when syncing to an external clock source.  Any Pro64 I/O module can be designated the Clock Master for the  network,
                    
                    Summary of the content on the page No. 14 
                    
                        Mode network, two 64-channel streams are available on the cable and  in each module. The configuration of the cables and ports has an impact  on the makeup of the network and the distribution of audio signals. The  user can direct A-Net data from an input module to a specific port (A,  B, or both). Output modules can be configured to output audio signals  from a specific port (A or B).   Support For Pro16 Series Products  Pro64 Series products can be combined with Pro16™ Series output  products 
                    
                    Summary of the content on the page No. 15 
                    
                        AC Power Always plug the unit into a properly grounded (earthed) outlet. Always  use the AC line cord that was shipped with the unit. Grasp the power  cable by the connector and never by the cord itself when connecting  and disconnecting it from the power source.  Do not expose the Pro64 device to moisture, rain, or excessively damp  environments.  AC Line Conditioning Aviom products are digital devices and as such are sensitive to sudden  spikes and drops in the AC line voltage. Changes in the 
                    
                    Summary of the content on the page No. 16 
                    
                        Ventilation Always allow adequate ventilation for devices mounted in equipment  racks. Avoid placing your Pro64 product directly above or below other  rack-mounted devices that produce high levels of heat, such as power  amplifiers. Cleaning Before cleaning a Pro64 product, turn off the power switch and unplug  the unit from the AC power source.  To clean the surface of the Pro64 product use a clean, soft lint-free cloth  that has been slightly moistened with water only. For tougher dirt, use a 
                    
                    Summary of the content on the page No. 17 
                    
                        Front Panel Components  The front panel components of the MH10 and MH10f are identical; the  MH10 is shown in the diagrams below.     1. Auto Mode LED  2. Manual Mode LED 3. Manual Mode configuration (A, B, C) indicator  4. Active A-Net port LED 5. A-Net LED 6. Managed Mode LED    Fro Nt PANel c o MPo Ne Nts                                                                                                                                                                                        
                    
                    Summary of the content on the page No. 18 
                    
                        MH10 Rear Panel     1. Power On/Off Switch 2. IEC Power Inlet 3. Fuse Holder 4. A-Net ports, EtherCon connectors, 10x 5. Manual Mode configuration selector button 6. Manual Mode configuration LED    0 Fro Nt PANel c o MPo Ne Nts                                                                                                                                                                                                                                                                         
                    
                    Summary of the content on the page No. 19 
                    
                        MH10f Rear Panel       1. Power On/Off Switch 2. IEC Power Inlet 3. Fuse Holder 4. Backup DC Power Inlet, 4-pin XLR  5. Manual Mode configuration selector button 6. Manual Mode configuration LED 7. A-Net ports, SFP connectors, 2x  8. A-Net ports, EtherCon connectors, 8x    r e Ar PANel c o MPo Ne Nts                                                                                                                                                                                             
                    
                    Summary of the content on the page No. 20 
                    
                        Front Panel Features  This section describes the features and functions of all front-panel  components of the MH10 and MH10f Merger Hubs.  Network Mode Indicator  The mode LED lights to display the current network mode, which can be  set to Auto or Manual at the network’s Control Master. When the Pro64  network is operating in Auto Mode, the red Auto LED will be lit. In Auto  Mode, no user settings are available on the MH10/MH10f; all ten A-Net  ports function identically. It does not matter whi