Summary of the content on the page No. 1 
                    
                        Scanning Guide for Colour Machines 
 
 
 
 
This guide covers the following machines: 
 
 
 
• C250/C252/C300/C351/C352/C450 
- Emperon and Fiery Controllers IC-402 & IC-406 
 
• C200/C203/C253/C353/C451/C550/C650 
- Emperon and Fiery Controller IC-409 
 
• C350 - Embedded Controller and the Fiery IC-401 
 
• Bizhub C10 
 
 
 
 
Version 6.0 
Colour V1.2                                                                                                                                                 
                    
                    Summary of the content on the page No. 2 
                    
                        CONTENTS    Scanning Tips & Tricks Page 3      Phase 3 onward Machines - With the Emperon  Controller  C250/C252/C300/C351/C352/C450    Scan to HDD Page 4  Scan to E-mail Page 6  Scan to FTP Page 8  Scan to SMB Page 9    Phase 3 onward Machines – C450/C351/C300/C352  With the Fiery Controllers IC-402 V2.01 & IC406 V1.01    Scan to HDD Page 10  Scan to E-mail Page 12  Scan to FTP Page 14  Scan to SMB (same as Emperon) Page 15    C203/C253/C353/C451/C550/C650 with Emperon Controller    Scan to HDD
                    
                    Summary of the content on the page No. 3 
                    
                                Scanning – Tips & Tricks    FTP    - PageScope Cabinet and the FTP Utility will not run on Windows 2003 , Vista or Server  2008, use the IIS service within these Operating Systems-  PageScope Cabinet needs to be open before scanning, or the FTP Service placed in the  Startup folder of the PC. (see the Konica Minolta FTP & SMB Setup Guide for Windows)    SMB    * - On Windows 2003 Domain Controller Server, you may find that you need to change  the Domain Security Setting    Security Optio
                    
                    Summary of the content on the page No. 4 
                    
                          Konica Minolta   C250/C252/C300/C351/C352/C450 with Emperon Controller    SCAN TO HDD    1) Using Internet Explorer, type the IP address of the Konica Minolta machine into  the address bar and press Go  2) Click on ‘Box’ at the top of the screen                                        3) Click on ‘Create User Box’  Created by Hotline Support  4 Konica Minolta Hotline Support (UK)                                                                                                                     
                    
                    Summary of the content on the page No. 5 
                    
                          4) Click Next                                      5) Type in your User Box Number, Name and Password.  6) Click Apply  7) A message saying ‘Completed’ will be displayed.  Click OK.    CREATING A ONE TOUCH BUTTON    1) Click on SCAN at the top of the screen  2) Click on New Registration  3) Choose the type of button you wish to create.  I.E. User Box  4) Click Next  5) Fill out the details for your box.  The Name is the name of the button that will  appear on the machine. The User Box No. must
                    
                    Summary of the content on the page No. 6 
                    
                            SCAN TO E-MAIL    1) Using Internet Explorer, type the IP address of the Konica Minolta machine into  the address bar and press Go   2) Click on Logout to logout of Public Mode. You will need to confirm you want to  logout.  3) Login to the Admin Mode by typing in the admin code of 12345678  4) Click on the orange Network tab  5) Click on E-mail Setting down the left hand side of the page  6) Click on E-mail TX (SMTP)  7) Ensure that ‘E-mail TX Setting’ and ‘Scan to E-mail’ are turned ‘ON’  
                    
                    Summary of the content on the page No. 7 
                    
                          CREATING A ONE TOUCH BUTTON    1) Following on from the instructions on page 6, log back in as a Public User  2) Click on SCAN at the top of the screen  3) Click on New Registration  4) Choose the type of button you wish to create.  I.E. E-mail  5) Click Next  6) Enter in the Name of the button you wish to appear on the machine, the Index  in which it is to appear under, and the E-mail Address you require your e-mails  sending to.                                          7) Click Apply and it 
                    
                    Summary of the content on the page No. 8 
                    
                          SCAN TO FTP    For information on configuring either PageScope Cabinet or IIS, please refer to  the Konica Minolta FTP & SMB Setup Guide for Windows.    PageScope Cabinet  - Page 4  IIS – XP   -  Page 5  IIS – Vista   - Page 6  IIS – Server 2008             -         Page 12    1) Using Internet Explorer, type the IP address of the Konica Minolta machine into  the address bar and press Go    2) Click on the ‘Scan’ tab at the top of the screen    3) Click on ‘New Registration’ and then choose ‘
                    
                    Summary of the content on the page No. 9 
                    
                            SCAN TO SMB    1) Create and configure shared folder on your C drive as on pages 20-26 of the  Konica Minolta FTP & SMB Setup Guide for Windows.    2) Using Internet Explorer, type the IP address of the Konica Minolta machine into  the address bar and press Go    3) Click on the SCAN tab at the top    4) Click on New Registration and choose SMB    5) Enter in the Name of the button to appear on the machine and select the  Index in which it is to appear under.    6) Type in the IP Address of 
                    
                    Summary of the content on the page No. 10 
                    
                          Konica Minolta – C300/C351/C352/C450 With the Fiery Controllers  (IC-402 & IC-406)     SCAN TO HDD    1) Using Internet Explorer, type the IP address of the Konica Minolta machine into  the address bar and press Go   2) Click on Login (Fiery) and type in the Administrator password for the Fiery   which is: Fiery.1  3) Click on the ‘Box’ tab at the top of the screen and click ‘Create’                                     4) Type in the Mailbox Name and password you require for your box. This is 
                    
                    Summary of the content on the page No. 11 
                    
                           CREATING A ONE TOUCH BUTTON    1)  Click on SCAN at the top of the screen  2)  Click on New Registration  3)  Choose the type of button you wish to create.  I.E. User Box (Scan)/(Store   Scanner)  4)  Click Next  5)  Enter in the Name of the button you wish to appear on the machine and   the Index which it should appear under.  The ‘User Box Name.’ is the name   of the box you created when you logged in to the Fiery screen.                                           6) Click Apply Created by H
                    
                    Summary of the content on the page No. 12 
                    
                          SCAN TO E-MAIL    PLEASE NOTE THAT AN E-MAIL ACCOUNT MUST BE SET UP ON THE E-MAIL  SERVER PRIOR TO SETTING UP THE MACHINE    1) Using Internet Explorer, type the IP address of the Fiery/machine into the address bar  and press Go     2) Click on Fiery Web Tools and the new look Web Tools will be displayed                                            3) Click on Configure, which will give you a summary of the current settings      Created by Hotline Support  12 Konica Minolta Hotline Support (UK) 
                    
                    Summary of the content on the page No. 13 
                    
                            4) Click on ‘Launch Configure’ and you will be prompted for a password.  The  password is the same as all new Fiery’s: Fiery.1    5) Click OK    6) Click on Network\Services\E-mail and the following screen will be displayed.    7) Enter in the required details.                                                    8) Click Apply and reboot the Fiery by clicking ‘Reboot’ in the bottom left hand corner  of the screen.      CREATING A ONE TOUCH BUTTON    1) Click on SCAN at the top of the screen  
                    
                    Summary of the content on the page No. 14 
                    
                            SCAN TO FTP    This setup for FTP scanning is the same as the Emperon controller.  Please refer  to Page 22 for machine configuration, and for information on configuring either  PageScope Cabinet or IIS, please refer to the following pages of the Konica  Minolta FTP & SMB Setup Guide for Windows.    PageScope Cabinet  - Page 4  IIS – XP   -  Page 5  IIS – Vista   - Pages 6  IIS – Server 2008             -         Page 12    However, you do need to enable FTP by opening up Web Tools from the 
                    
                    Summary of the content on the page No. 15 
                    
                          SCAN TO SMB    1) Create a shared folder on your C drive as on pages 20-26 of the Konica  Minolta FTP & SMB Setup Guide for Windows.    2) Using Internet Explorer, type the IP address of the Konica Minolta machine into  the address bar and press Go    3) Click on the SCAN tab at the top    4) Click on New Registration and choose SMB    5) Enter in the Name of the button to appear on the machine and select the  Index in which it is to appear under.    6) Type in the IP Address of the computer a
                    
                    Summary of the content on the page No. 16 
                    
                          C203/C253/C353/C451/C550/C650 with the Emperon  Controller    SCAN TO HDD    1) Using Internet Explorer, type the IP address of the machine into the   address bar and press Go    2) Click on the ‘Box’ tab at the top of the screen    3) Click on ‘Create User Box’                                          4) Enter a ‘User Box Name’, ‘Password’ if required and ‘Index’ under which the  machine will place the box.                                    Created by Hotline Support  16 Konica Minolta Hotli
                    
                    Summary of the content on the page No. 17 
                    
                            5) Click ‘OK’ and ‘OK’ again to the ‘Completed’ message    CREATING A ONE TOUCH BUTTON    1) Click on the ‘Store Address’ tab    2) Click on ‘New Registration’    3) Choose ‘User Box’ from the next screen and click ‘OK’    4) Leave the ‘Use Opening Number’ option selected.    * Give your scan button a name.  (This is the name of the button that will       appear on the machine).    * Select the ‘Index’ under which that button is to appear.  * Enter the number for the box you created previous
                    
                    Summary of the content on the page No. 18 
                    
                          SCAN TO E-MAIL    1) Using Internet Explorer, type the IP address of the Konica Minolta machine into  the address bar and press Go    2) Log in to Administrator Mode using the default password of: 12345678    3) Under the ‘Maintenance’ screen, click on ‘Machine Setting’    4) Enter an ‘Administrator Name’ and ‘Admin E-mail Address’                                      5) Click ‘OK’ and ‘OK’ again.     6) Click on the ‘Network’ tab at the top of the screen    7) Down the left hand side of the s
                    
                    Summary of the content on the page No. 19 
                    
                          8) Ensure that ‘E-mail TX Setting’ and ‘Scan to E-mail’ are turned ‘ON’    9) Enter in the IP address or Host Name of the E-mail server    10) Enter a ‘Device Mail Address’    11) If required, turn on ‘SMTP Authentication’ and enter a user name and  password of a user set up on the e-mail server.  It is recommended that if you  need to use this setting, that a new e-mail account for the Konica Minolta device  is created on the e-mail server.    12) Ensure that ‘Binary Division’ is turned ‘OFF’
                    
                    Summary of the content on the page No. 20 
                    
                          SCAN TO FTP  For information on configuring either PageScope Cabinet or IIS, please refer to  the following pages of the Konica Minolta FTP & SMB Setup Guide for  Windows.    PageScope Cabinet  - Page 4  IIS – XP   -  Page 5  IIS – Vista   - Pages 6  IIS – Server 2008             -         Page 12    1) Using Internet Explorer, type the IP address of the Konica Minolta machine into  the address bar and press Go    2) Click on the ‘Store Address’ tab at the top of the screen    3) Click on ‘New