Summary of the content on the page No. 1 
                    
                        Stratix 8000 Ethernet 
Managed Switches 
Hardware User Manual
Catalog Numbers  1783-MS06T, 1783-MS10T,
1783-MX08T, 1783-MX08F                                                                                                                                                                                                                                                                                                                                                                                       
                    
                    Summary of the content on the page No. 2 
                    
                        Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the  Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales  office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard- wired electromechanical devices. Because of this difference,
                    
                    Summary of the content on the page No. 3 
                    
                        Preface This publication describes the physical and performance characteristics of the  About This Publication Stratix 8000 Ethernet Managed Switches. In addition, this publication provides  the following: • Detailed installation information • How to use the switch • Troubleshooting information This guide does not describe system messages that you might receive or how  to configure your switch. For this information, see the Additional Resources  section on page 6.  This guide is for the person i
                    
                    Summary of the content on the page No. 4 
                    
                        Preface         These documents contain additional information concerning this Rockwell  Additional Resources Automation product. Resource Description Stratix 8000 Ethernet Managed Switches Describes how to get started installing and  Installation Instructions, publication configuring the switch. 1783-IN005 Stratix 8000 Ethernet Managed Switches Provides detailed information on configuring  Software User Manual, publication and managing your switches. 1783-UM003 Stratix 8000 Ethernet Managed Swi
                    
                    Summary of the content on the page No. 5 
                    
                        Table of Contents Preface About This Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Who Should Use This Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Chapter 1 Start About the Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Power and Relay Connector . . . . . . . . . . . . . . . . .
                    
                    Summary of the content on the page No. 6 
                    
                        Reset the Switch to Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Connect to the Switch Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Connect to 10/100 Copper Ports . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Connect to Dual-purpose Uplink (10/100/1000 and SFP Fiber)  Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Connect to 100BaseFX Ports . . . . . . . . . . . . . . . .
                    
                    Summary of the content on the page No. 7 
                    
                        Chapter 1 Start This chapter provides a functional overview of the switches and covers these  topics. Topic Page About the Switches 8 Power and Relay Connector 11 Console Port 12 Dual-Purpose Uplink Ports 12 10/100 Ports 13 100BASE-FX Ports 13 Rear Panel 13 Cabling 14 Status Indicators 15 CompactFlash Memory Card 19 7Publication 1783-UM002C-EN-P - April 2009 7                                                                                                                                          
                    
                    Summary of the content on the page No. 8 
                    
                        Chapter 1         The Stratix 8000 Ethernet Managed Switches provide a rugged, easy-to-use,  About the Switches secure switching infrastructure for harsh environments. You can connect these  switches to network devices such as servers, routers, and other switches. In  industrial environments you can connect any Ethernet-enabled industrial  communication devices including programmable logic controllers (PLCs),  human-machine interfaces (HMIs), drives, sensors, and I/O.  You can mount the switches
                    
                    Summary of the content on the page No. 9 
                    
                                Chapter 1 1783-MS10T Switch       1 Power and relay connectors 2 Console port 3 Dual-purpose ports  4 10/100 ports 5 Protective ground connection Publication 1783-UM002C-EN-P - April 2009 9                                                                                                                                                                                                                                                                                                               
                    
                    Summary of the content on the page No. 10 
                    
                        Chapter 1         1783-MX08T Switch Copper Expansion Module (side cover removed) 31827-M 1 1 10/100 ports 1783-MX08F Switch Fiber Expansion Module 1 31828-M 1 100BASE-FX ports  10 Publication 1783-UM002C-EN-P - April 2009                                                                                                                                                                                                                                                                                       
                    
                    Summary of the content on the page No. 11 
                    
                        A A V RT         Chapter 1 You connect the DC power and alarm signals to the switch through two front  Power and Relay Connector panel connectors. One connector provides primary DC power (supply A) and  the major alarm signal, and a second connector (supply B) provides secondary  power and the minor alarm signal. The two connectors are physically identical  and are in the upper left side of the front panel, as shown in the figure below. The switch accessory pack includes the mating power and rel
                    
                    Summary of the content on the page No. 12 
                    
                        Chapter 1         See the Stratix 8000 Ethernet  Managed Switches Software User Manual,  publication 1783-UM003A, for  more information on alarm configuration.. For more information about the power and relay connector, see Chapter 4,  Cable and Connectors. For configuring, monitoring, and managing the switch, you can connect a  Console Port switch to a computer through the console port and the supplied RJ45-to-DB-9  adapter cable. If you want to connect a switch to a terminal, you need to  provi
                    
                    Summary of the content on the page No. 13 
                    
                                Chapter 1 You can set the 10/100 ports to operate at 10 or 100 Mb/s in full-duplex or  10/100 Ports half-duplex mode. You can also set these ports for speed and duplex  autonegotiation in compliance with IEEE 802.3-2002. (The default setting is  autonegotiate.)  When set for autonegotiation, the port senses the speed and duplex settings of  the attached device. If the connected device also supports autonegotiation, the  switch port negotiates the best connection (that is, the fastest lin
                    
                    Summary of the content on the page No. 14 
                    
                        Chapter 1         100BASE-TX traffic requires Category 5 cable. 10BASE-T traffic can use  Cabling Category 3 or Category 4 cables. When connecting the switch to workstations, servers, and routers,  straight-through cables are normally used.   However, the automatic  medium-dependent interface crossover (auto-MDIX) feature of the switch is  enabled by default and will automatically re-configure the ports to use either  straight-through or crossover cable type.  Auto-MDIX Feature The Auto-MDIX fea
                    
                    Summary of the content on the page No. 15 
                    
                        VRT A A         Chapter 1 The switches and expansion modules have these status indicators. Status Indicators Switch and Port Status Indicators EIP Mod Status Indicator EIP Net Status Indicator Setup Status Indicator PWR A Status  PWR B Status Indicator Port Status Indicator  Indicator Dual-purpose Port  Status Indicator  31793-M Indicator State Description EIP Mod Off No power. Check the power supply and cabling.  (EtherNet/IP module status) Solid green The switch is operating properly. Flashing
                    
                    Summary of the content on the page No. 16 
                    
                        Chapter 1         Indicator State Description Setup Off Switch is configured as a managed switch. Solid green Switch is in initial setup. Flashing green Switch is in one of the following states; • initial setup • recovery • initial setup incomplete Solid red Switch failed to start initial setup or recovery because there is no  available switch port to which to connect the management station. Disconnect a device from a switch port, and press the Express Setup  button.  PWR A and PWR B Off Power i
                    
                    Summary of the content on the page No. 17 
                    
                                Chapter 1 Dual-purpose Port Status Indicators The status indicators on a dual-purpose port, as shown in the following figure, show whether  the RJ45 connector or an SFP module is active. The port can be configured as either a  10/100/1000 port through the RJ45 connector or as an SFP module, but not both. The status  indicators show which port is being used, and current port activity. RJ45 Port In-use and Activity  Status Indicator SFP Module Port RJ45 Port SFP Module Port In-use and Acti
                    
                    Summary of the content on the page No. 18 
                    
                        Chapter 1         Expansion Module Status Indicators State Description Off No link. Solid green Link present. Flashing green Activity. Port is sending or receiving data. Flashing amber A link blocked by spanning tree is sending or receiving data. Alternating Link fault. Error frames can affect connectivity, and errors such as excessive collisions, CRC errors, and alignment and  green/amber jabber errors are monitored for a link-fault indication (RJ45 connection only). Solid amber Port is not for
                    
                    Summary of the content on the page No. 19 
                    
                        VRT A A         Chapter 1 The switch supports a CompactFlash memory card that makes it possible to  CompactFlash Memory  replace the switch without reconfiguring the switch. The slot for the  Card CompactFlash memory card is on the bottom of the switch as shown in the  following figure. 31792-M Although the switch is shipped with the CompactFlash memory card installed,  you can insert or remove the CompactFlash memory card by grasping the tab  on the card and either inserting it or removing it f
                    
                    Summary of the content on the page No. 20 
                    
                        Chapter 1         Notes: 20 Publication 1783-UM002C-EN-P - April 2009