Agilent Technologies 83434A user manual

User manual for the device Agilent Technologies 83434A

Device: Agilent Technologies 83434A
Category: Car Satellite TV System
Manufacturer: Agilent Technologies
Size: 1.99 MB
Added : 4/15/2014
Number of pages: 62
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Agilent Technologies 83434A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Agilent Technologies 83434A.

For your convenience

If looking through the Agilent Technologies 83434A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Agilent Technologies 83434A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Agilent Technologies 83434A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Agilent Technologies 83434A User manual - Online PDF
Advertisement
« Page 1 of 62 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Agilent Technologies 83434A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Agilent Technologies 83434A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Agilent 83434A
Lightwave Receiver
User’s Guide

Summary of the content on the page No. 2

© Copyright Warranty. Exclusive Remedies. | The ON symbols are This Agilent Technologies The remedies provided herein Agilent Technologies 2000 used to mark the posi- instrument product is war- are buyer's sole and exclusive All Rights Reserved. Repro- tions of the instrument ranted against defects in remedies. Agilent Technolo- duction, adaptation, or trans- power line switch. material and workmanship for gies shall not be liable for any lation without prior written a period of one year f

Summary of the content on the page No. 3

General Safety Considerations General Safety Considerations This product has been designed and tested in accordance with IEC Publica- tion 61010-1, Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, and has been supplied in a safe condition. The instruction documentation contains information and warnings that must be followed by the user to ensure safe operation and to maintain the product in a safe condition. WARNING If this instrument is not used as

Summary of the content on the page No. 4

General Safety Considerations temperature of the product by 4°C for every 100 watts dissipated in the cabinet. If the total power dissipated in the cabinet is greater than 800 watts, then forced convection must be used. CAUTION Always use the three-prong ac power cord supplied with this instrument. Failure to ensure adequate earth grounding by not using this cord may cause instrument damage. CAUTION Do not connect ac power until you have verified the line voltage is correct as described in

Summary of the content on the page No. 5

The Agilent 83434A—At a Glance The Agilent 83434A—At a Glance The Agilent 83434A 10 Gb/s lightwave receiver is designed to recover clock data and to provide linear, non-retimed data from digitally modulated SDH/ SONET STM-64/OC-192 optical signals, as well as signals employing forward error correction (FEC) at 10.664 Gb/s (option 106). The receiver is based on an amplified PIN receiver to produce a linear output with AGC stabilization. The receiver is designed to provide –16 dBm sensitivity

Summary of the content on the page No. 6

Summary of the content on the page No. 7

Contents General Safety Considerations iii The Agilent 83434A—At a Glance v 1 Getting Started 2 Using the Agilent 83434A Front-Panel Features 2-2 Rear-Panel Features 2-3 Quick Confidence Check 2-4 Agilent 83434A Connection to a Bit-Error-Ratio Test Set 2-6 BER Performance Verification 2-9 3 Reference Accessories Supplied 3-2 Options 3-3 Replacement Parts 3-4 Front-Panel Fiber-Optic Adapters 3-5 Power Cords 3-7 Fiber-Optic Connectors 3-8 Instrument Service 3-18 4 Specifications and Regulatory Inf

Summary of the content on the page No. 8

Contents Contents-2

Summary of the content on the page No. 9

1 Step 1. Inspect the Shipment 1-3 Step 2. Check the Fuse 1-5 Step 3. Connect the Line-Power Cable 1-6 Step 4. Turn on the Agilent 83434A 1-8 Step 5. Avoid costly repairs 1-9 Step 6. Learn more about our products 1-10 Getting Started

Summary of the content on the page No. 10

Getting Started Setting Up the Agilent 83434A Setting Up the Agilent 83434A This chapter shows you how to install your lightwave receiver. After you’ve completed this chapter, continue with Chapter 2, “Using the Agilent 83434A”. Refer to Chapter 3, “Reference” for the following additional information:  Tips on avoiding costly repairs by proper optical connection cleaning techniques.  Lists of available accessories and power cords.  Instructions on returning your instrument to Agilent Techn

Summary of the content on the page No. 11

Getting Started Setting Up the Agilent 83434A Step 1. Inspect the Shipment ❒ Inspect the shipping container for damage. ❒ Inspect the instrument. ❒ Verify that you received the accessories you ordered. Keep the shipping container and cushioning material until you have inspected the contents of the shipment for completeness and have checked the light- wave receiver mechanically and electrically. The lightwave receiver is packed within a carton. Refer to “Instrument Ser- vice” on page 3-18, for t

Summary of the content on the page No. 12

Getting Started Setting Up the Agilent 83434A lent Technologies Sales Office. Keep the shipping materials for the carrier’s inspection. The Agilent Sales Office will arrange for repair or replacement at Agilent Technologies’ option without waiting for claim settlement. Serial numbers Agilent Technologies makes frequent improvements to its products to enhance their performance, usability, or reliability, and to control costs. Agi- lent service personnel have access to complete records of desig

Summary of the content on the page No. 13

Getting Started Setting Up the Agilent 83434A Step 2. Check the Fuse 1 Locate the line-input connector on the instrument’s rear panel. 2 Disconnect the line-power cable if it is connected. 3 Use a small flat-blade screwdriver to pry open the fuse holder door. 4 The fuse is housed in a small container. Insert the tip of a screwdriver on the side of the container and gently pull outward to remove the container. A spare fuse is stored below the line fuse. WARNING For continued protection against

Summary of the content on the page No. 14

Getting Started Setting Up the Agilent 83434A Step 3. Connect the Line-Power Cable CAUTION Always use the three-prong AC power cord supplied with this instrument. Failure to ensure adequate earth grounding by not using this cord may cause instrument damage. CAUTION Do not connect ac power until you have verified the line voltage is correct as described in the following paragraphs. Damage to the equipment could result. CAUTION This instrument has autoranging line voltage input. Be sure the sup

Summary of the content on the page No. 15

Getting Started Setting Up the Agilent 83434A 1 Verify that the line power meets the requirements shown in the following table. Line Power Requirements Power 115 VAC: 50 Watts MAX 230 VAC: 50 Watts MAX Voltage nominal: 115 VAC range:90–132 V nominal:230 VACrange:98–254 V Frequency nominal:50 Hz/60 Hzrange:47–63 Hz 2 Connect the line-power cord to the rear-panel connector of the instrument. 3 Connect the other end of the line-power cord to the power receptacle. Various power cables are availabl

Summary of the content on the page No. 16

Getting Started Setting Up the Agilent 83434A Step 4. Turn on the Agilent 83434A With the power cable inserted into the line module, turn the lightwave receiver on by pressing the line switch. The green light-emitting diode (LED) should light. NOTE The front panel LINE switch disconnects the mains circuits from the mains supply after the EMC filters and before other parts of the instrument. If the Agilent 83434A fails to turn on properly, consider the following possibili- ties: ❒ Is the line

Summary of the content on the page No. 17

Getting Started Setting Up the Agilent 83434A Step 5. Avoid costly repairs CAUTION Fiber-optic connectors are easily damaged when connected to dirty or damaged cables and accessories. The front-panel connectors of the Agilent 83434A are no exception. When you use improper cleaning and handling techniques, you risk expensive instrument repairs, damaged cables, and compromised measurements. Before you connect any fiber-optic cable to the Agilent 83434A, refer to “Fiber-Optic Connectors” on pa

Summary of the content on the page No. 18

Getting Started Setting Up the Agilent 83434A Step 6. Learn more about our products To learn more about Agilent Technologies products, visit our website at http://www.agilent.com. If you wish to find out more about your new lightwave receiver, use the key- word “83434A” in your search. 1-10

Summary of the content on the page No. 19

2 Front-Panel Features 2-2 Rear-Panel Features 2-3 Quick Confidence Check 2-4 Agilent 83434A Connection to a Bit-Error-Ratio Test Set 2-6 BER Performance Verification 2-9 Using the Agilent 83434A

Summary of the content on the page No. 20

Using the Agilent 83434A Front-Panel Features Front-Panel Features Figure 2-1. The Agilent 83434A front panel. CLOCK OUT Output is nominally 9.95328 GHz or 10.66423 GHz (option 106). DATA OUT Provides an amplified, non-retimed signal corresponding to the incoming data stream. OPTICAL IN Maximum signal input is 0 dBm, damage level input is +7 dBm. This input accepts any of the Agilent 81000-series connector interface adapters. INPUT PRESENT Indicates the presence of sufficient optical


Alternative user manuals
# User manual Category Download
1 Philips DTR User manual Car Satellite TV System 1
2 AOC T2442e User manual Car Satellite TV System 2
3 Denon AVR-4520CI User manual Car Satellite TV System 23
4 Sony SA-VE2M User manual Car Satellite TV System 3
5 Ericsson ATSC Broadcast Receiver RX8320 User manual Car Satellite TV System 5
6 Sony WRR-855A User manual Car Satellite TV System 9
7 Humax SATBox LUG-17DS User manual Car Satellite TV System 13
8 Sony XT-V70 User manual Car Satellite TV System 2
9 AOC WB81 User manual Car Satellite TV System 252
10 Kathrein UAS 572 User manual Car Satellite TV System 28
11 Sony KDL-52XBR6 User manual Car Satellite TV System 1
12 JVC 50050690 User manual Car Satellite TV System 0
13 Sony KV-27FS120 User manual Car Satellite TV System 1
14 Hyundai CD/MP3-RECEIVER H-CDM8010 User manual Car Satellite TV System 16
15 Sony DAB/FM/AM Receiver STR-DB895D User manual Car Satellite TV System 4