KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood user manual

User manual for the device KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood

Device: KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood
Category: Ventilation Hood
Manufacturer: KitchenAid
Size: 0.6 MB
Added : 12/7/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood.

For your convenience

If looking through the KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation Instructions and
Use and Care Guide
36" (91.4 cm)
48" (121.9 cm)
Island Canopy Range Hood
Quick Reference
IMPORTANT:
Table of Contents:
Read and save
Pages
2
Before you start
these instructions.
3 Product dimensions
3
Cabinet dimensions
3 Venting requirements
IMPORTANT:
5
Electrical requirements
Installer: Leave Installation Instructions with
the homeowner.
5 - 7 Installation steps
Homeowner: Keep Installation Instructions for
8
Use and Care Information
future reference.
9
Wiring

Summary of the content on the page No. 2

Parts needed: WARNING — TO REDUCE THE Before you start... RISK OF FIRE, ELECTRIC SHOCK, 2 U.L.- or C.S.A.- listed, 1/2" (12.5 mm) OR INJURY TO PERSONS, conduit connectors OBSERVE THE FOLLOWING: Your safety and the safety of power supply cable Installation work and electrical others is very important. 1 wall or roof cap wiring must be done by qualified We have provided many important metal vent system person(s) in accordance with all safety messages in this manual and applicable Codes and Standar

Summary of the content on the page No. 3

Cabinet dimensions Product dimensions 10 7/8" (27.6 cm) 7 1/16" support (17.9 cm) structure upper chimney 1" (2.5 cm) min. - 11-1/8" (23.8 cm) max. upper chimney height 24-5/8" (62.5 cm) min. - lower chimney 23-5/8" 34-3/4" (88.3 cm) max. (60 cm) overall chimney height lower chimney height canopy 10-1/4" (26 cm) canopy height 23-5/8" (60 cm) 36" hood 35-3/8" (89.9 cm) or 24" (61 cm) min. 8’ (2.4 m) min. - overall depth 48" hood 47-1/4" (120 cm) bottom of canopy 9’ (2.7 m) max. overall widt

Summary of the content on the page No. 4

Venting methods Vertical roof venting Horizontal wall venting This island canopy range hood is factory set for venting through the roof roof cap or wall. For non-vented (recirculating) 3-1/4" x 10" 3-1/4" x 10" installations, see “Non-Vented (8.3 cm x 25 cm) (8.3 cm x 25 cm) wall (Recirculating) Kits” on back page. through through the wall cap the roof Vent system needed for installation is not included. 3-1/4" x 10" (8.3 cm x 25 cm) rectangular, 7" (17.8 cm) round, 8" (20.3 cm) round or 9" (

Summary of the content on the page No. 5

Electrical requirements supply cable. Wire sizes (COPPER separate 15-amp circuit, fused on Important: Observe all governing WIRE ONLY) and connections must both sides of the line. codes and ordinances. conform with the rating of the Do not ground to a gas pipe. It is the customer’s responsibility: appliance as specified on the Check with a qualified electrician • To contact a qualified electrical model/serial rating plate. if you are not sure range hood is installer. Wire sizes must conform to t

Summary of the content on the page No. 6

. Electrical 7. Align support mounting bracket 10. Remove the terminal box with holes in ceiling. Attach support cover from the range hood. Remove connection system frame to ceiling using anchors the power supply cable knockout recommended for your type of ceiling: using a flat-blade screwdriver. Do not • Concrete ceiling — use inserts and remove optional remote blower WARNING screws provided. knockout. Attach conduit connector • Wood ceiling — use 4" (10.2 cm) into power supply cable opening

Summary of the content on the page No. 7

Install chimney Check operation sections upper chimney 17. Turn power on. trim 13. Connect vent to damper or hood and seal all connections with duct tape. chimney clips holes upper chimney support lower system frame chimney trim control panel chimney location clip holes 18. The island canopy hood controls are located in a grey panel on underside of the canopy. To open the panel, press on the front edge of trim clip panel and release. The control panel will drop down. screw 15. Cut upper chimney

Summary of the content on the page No. 8

Use and Care Information WARNING — TO REDUCE THE DO NOT USE WATER, including RISK OF FIRE, ELECTRIC SHOCK, wet dishcloths or towels — a OR INJURY TO PERSONS, violent steam explosion will OBSERVE THE FOLLOWING: result. Use an extinguisher ONLY if: Use this unit only in the manner intended by the manufacturer. If You know you have a Class ABC you have questions, contact the extinguisher, and you already light blower blower speed manufacturer. Before servicing or know how to operate it. switch s

Summary of the content on the page No. 9

Maintenance Replacing the light bulb: This range hood uses fluorescent lamp type F33-15W-T8 and starter type 52. Remove the retainer clips from both ends of the light cover. Carefully slide the cover all the way to the right. Then lower the left end of the glass below the support flange and remove the glass by sliding it back from the left. support Install a new fluorescent light bulb. flange Position the right end of the light cover over the flange and slide the cover all the retainer clips

Summary of the content on the page No. 10

Warranty ® KITCHENAID VENTILATION WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, KitchenAid or KitchenAid Canada (hereafter “KitchenAid”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a KitchenAid designated service company. ITEMS KITCHENAID WILL NOT PAY FOR 1. Se

Summary of the content on the page No. 11

Requesting Assistance or Service To avoid unnecessary service calls, please check the “Check Operation” section. It may save you the cost of a service call. If you still need help, follow the instructions below. If you need assistance or service in U.S.A. Call the KitchenAid Customer Interaction Use and maintenance procedures • Center toll-free at 1-800-422-1230. Accessory and repair parts sales • Our consultants are available to assist you. Specialized customer assistance (Spanish • When callin

Summary of the content on the page No. 12

Requesting Assistance or Service Before calling for assistance or service, please check the “Check Operation” section. It may save you the cost of a service call. If you still need help, follow the instructions below. If you need assistance or service in Canada ✝ 2. If you need service ... 1. If the problem is not due to one of the items ✝ Contact your nearest KitchenAid Canada listed in “Check Operation” ... Appliance Service branch or authorized servicing Contact the dealer from whom you out

Summary of the content on the page No. 13

Instructions d’installation et Guide d’utilisation et d’entretien Hotte d’aspiration pour cuisinière - montage sur îlot 91,4 cm (36 po) 121,9 cm (48 po) Référence rapide IMPORTANT : Table des matières : Lire et conserver ces Pages instructions. 2 Avant de commencer... 3 Dimensions du produit 3 Dimensions des placards 3 Circuit de décharge de l’air IMPORTANT : 5 Alimentation électrique Installateur : Remettre les instructions d’installation au propriétaire de l’appareil. 5 - 7 Les étapes de l

Summary of the content on the page No. 14

Pièces nécessaires : AVERTISSEMENT - POUR RÉDUIRE LE Avant de commencer... RISQUE D’INCENDIE, CHOC ÉLECTRIQUE 2 connecteurs de conduit 12,5 mm (1/2 po) - OU BLESSURE, RESPECTER LES INSTRUC- homologation U.L. ou ACNOR TIONS SUIVANTES : V Vo ot tr re e s sé éc cu ur ri it té é e et t c ce el ll le e d de es s a au ut tr re es s câble d’alimentation Tout travail d’installation ou câblage élec- e es st t t tr rè ès s i im mp po or rt ta an nt te e. . 1 bouche de décharge pour toit ou mur

Summary of the content on the page No. 15

Dimensions des placards Dimensions du produit 27,6 cm (10 7/8 po) 17,9 cm structure de (7 1/16 po) support cheminée - Cheminée - section supérieure section supérieure hauteur de 2,5 cm (1 po) min. à 23,8 cm (11 1/8 po) max. Cheminée - hauteur totale Cheminée - cheminée - 62,5 cm (24 5/8 po) min. à section section inférieure 88,3 cm (34 3/4 po) max. inférieure 60 cm (23 5/8 po) hotte Hauteur de la hotte 26 cm (10 1/4 po) Profondeur hors-tout Largeur hors-tout Distance min. entre le 60 cm (23

Summary of the content on the page No. 16

Configurations de Décharge à travers le toit Décharge horizontale à travers le mur circuit de décharge bouche de décharge La hotte d’aspiration pour îlot est configurée à l’usine pour la décharge à travers le toit ou un conduit de 8,3 x 25 cm conduit de 8,3 x 25 cm bouche de mur. Pour une installation sans évacuation de (3 1/4 x 10 po) - (3 1/4 x 10 po) - décharge décharge l’air (recyclage), voir en dernière page la section décharge à travers le toit à travers le mur murale « Hottes à recyclag

Summary of the content on the page No. 17

Alimentation électrique Ne pas utiliser une tuyauterie de gaz pour la doivent être compatibles avec la demande de Important : Respecter les prescriptions de liaison à la terre. courant de l’appareil spécifiée sur la plaque tous les codes et règlements en vigueur. signalétique. En cas d’incertitude quant à la qualité de la C’est au client qu’incombe la responsabilité liaison à la terre de la hotte, consulter un La taille des conducteurs doit satisfaire les de : électricien qualifié. prescriptions

Summary of the content on the page No. 18

Raccordement au 7. Aligner la bride de montage avec les 10. Ôter le couvercle de la boîte de trous percés dans le plafond. Fixer la réseau électrique connexion de la hotte. À l’aide d’un tournevis structure de support au plafond; utiliser les à lame plate, arracher l’opercule de l’orifice de organes d’ancrage recommandés pour le type passage du câble d’alimentation. Ne pas de plafond : arracher l’opercule destiné à un ventilateur AVERTISSEMENT • Plafond de béton - utiliser les chevilles monté à

Summary of the content on the page No. 19

Installation des sections Contrôle du de la cheminée fonctionnement garniture supérieure de la 17. Mettre le système sous tension. 13. Connecter le conduit cheminée d’évacuation à la section du volet de réglage/fermeture ou à la hotte; assurer trous l’étanchéité de chaque jointure avec du ruban agrafes dans la cheminée adhésif pour conduits. cheminée - section supérieure structure garniture de support inférieure de la cheminée emplacement des organes de commande trous dans la agrafe cheminée

Summary of the content on the page No. 20

Renseignements d’utilisation et entretien AVERTISSEMENT - POUR MINIMISER LE Il s’agit d’un petit feu encore limité à l’en- RISQUE D’INCENDIE, CHOC ÉLECTRIQUE OU droit où il s’est déclaré. DOMMAGES CORPORELS, RESPECTER LES Les pompiers ont été contactés. INSTRUCTIONS SUIVANTES : Il est possible de garder le dos orienté vers Utiliser cet appareil uniquement dans les une sortie pendant l’opération de lutte con- applications envisagées par le fabricant. Pour tre le feu. toute question, contacter le


Alternative user manuals
# User manual Category Download
1 KitchenAid 30 User manual Ventilation Hood 4
2 KitchenAid 36"(91.4CM) ISLAND RANGE HOOD User manual Ventilation Hood 6
3 KitchenAid 36 User manual Ventilation Hood 1
4 KitchenAid 30" (76.2 cm) 36" (91.4 cm) 48" (121.9 cm) Wall-Mount Canopy Range Hood User manual Ventilation Hood 7
5 KitchenAid 4329223 User manual Ventilation Hood 1
6 KitchenAid 4360369 User manual Ventilation Hood 1
7 KitchenAid 30" and 36" Retractable Downdraft Vent Systems User manual Ventilation Hood 7
8 KitchenAid 6899551 User manual Ventilation Hood 1
9 KitchenAid 48 User manual Ventilation Hood 1
10 KitchenAid 883297 User manual Ventilation Hood 1
11 KitchenAid 883298 User manual Ventilation Hood 2
12 KitchenAid 42 User manual Ventilation Hood 0
13 KitchenAid 6899552 User manual Ventilation Hood 1
14 KitchenAid 9763388 User manual Ventilation Hood 1
15 KitchenAid KGCP462KSS User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0