Summary of the content on the page No. 1 
                    
                        LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA. 
Por servicio o reparación, 
NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA, INCLUYENDO 
no devuelva esta unidad 
Automatic Wrist 
NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA 
al distribuidor. Póngase en 
OBLIGACIÓN POR PARTE DE LA COMPAÑÍA CON RESPECTO A PRODUCTOS 
contacto con Relaciones 
CUBIERTOS POR ESTA GARANTÍA. HOMEDICS NO TENDRÁ RESPONSABILIDAD 
Blood Pressure Monitor 
con el Consumidor de 
ALGUNA P
                    
                    Summary of the content on the page No. 2 
                    
                        TABLE OF CONTENTS INTRODUCTORY INFORMATION: Risk Category Index .................................26 Important Product Notices and  Irregular Heartbeat Detector (IHB) .........27 Safety Instructions .....................................3 Recalling Values from Memory ................28 About Blood Pressure ................................6  Clearing Values from Memory .................30  What is Blood Pressure? Important Notes Regarding Your   Why Measure Your Blood Pressure? Blood Pressure Measu
                    
                    Summary of the content on the page No. 3 
                    
                        �  This product is not suitable for people with  arrhythmias. This device may have difficulty  determining the proper blood pressure for  individuals with irregular heartbeat, diabetes,  poor circulation of blood, kidney problems or  IMPORTANT PRODUCT NOTICES AND  for users who have suffered from a stroke. SAFETY INSTRUCTIONS �  Consult your physician before measuring  When using your blood pressure monitor, basic  blood pressure at the wrist if you have any of  precautions should always be foll
                    
                    Summary of the content on the page No. 4 
                    
                        �  Not for use by or on persons under the age of 18 ABOUT BLOOD PRESSURE �  Use only 1.5V AAA alkaline batteries for power  What is Blood Pressure? supply.  Blood pressure is the pressure exerted on the artery  Blood pressure measurements determined with this  walls while blood flows through the arteries. The  device are equivalent to those obtained by a trained  pressure measured when the heart contracts and  observer using the cuff/stethoscope auscultatory  sends blood out of the heart is syst
                    
                    Summary of the content on the page No. 5 
                    
                        automatically compares each reading to this criteria  BLOOD PRESSURE STANDARD and provides a helpful cue if your reading falls into  The table below is criteria for hypertension that  one of the stages that could potentially indicate  is publicly available from the National Heart Lung  increased risk.  See page 26 for more information  and Blood Institute at the U.S. National Institutes of  on this feature.    Health (NIH) (http://www.nhlbi.nih.gov/health/dci/Diseases/   Hbp/HBP_WhatIs.html). Us
                    
                    Summary of the content on the page No. 6 
                    
                        measurement is complete, the monitor will display  NAME/FUNCTION OF EACH PART your systolic pressure, diastolic pressure, and pulse  1. LANGUAGE Button readings. TALKING LANGUAGE MODE 2. TALKING MODE Button  12 3 3. Date/Time Set Buttons The monitor automatically finds where your  measurement results fall on the NIH’s National Heart  User-Select  LCD Display Lung and Blood Institute’s table and provides a cue  Button if your reading falls into one of the stages that could  potentially indicate i
                    
                    Summary of the content on the page No. 7 
                    
                        DISPLAY EXPLANATIONS Display Symbols: User 1:  Appears when the monitor is operated by User 1 User 2:  Appears when the monitor is operated by User 2 Systolic  Weak Battery Symbol:  Appears when batteries should  Pressure be replaced Pulse Symbol: Shows the pulse rate per minute Irregular Heartbeat Detector: Refer to page 27 for more  information. Diastolic  Pressure Memory Average: Displays average of last 3 readings Risk Category Index: See page 26 for more information. Pulse  Rate Talking Fea
                    
                    Summary of the content on the page No. 8 
                    
                        INSTALLING BATTERIES Replace the batteries if: 1.  The weak battery symbol appears on the display.  1. 2.  Nothing appears on the display when the power is  1.  The battery cover is located  switched on. along the bottom side of the  monitor. Remove battery cover  by pressing down and pulling As the supplied batteries are for test only, they may  away from the monitor. be discharged earlier than batteries you buy in stores.  Replace all batteries at one time (as simultaneous set).  Use only 1.5V
                    
                    Summary of the content on the page No. 9 
                    
                        DATE & TIME SET PROCEDURE USING THE VOICE ASSIST™  TALKING FUNCTION 1.  To adjust the date/time, press the Set button     located on the top of the monitor.  The Voice Assist feature will guide you through the  measurement procedure and also announce results  2. The display will show a blinking number showing  after your reading. The Voice Assist™ Talking Function  the HOUR. Change the HOUR by pressing the is not a substitute for reading and understanding the  instruction manual.   button. Each 
                    
                    Summary of the content on the page No. 10 
                    
                        3.  When the  appears with the letters “InS oFF”, Setting the Language: this indicates the monitor is in “Instructions Off”  The Voice Assist talking function announces results  Mode. in English or Spanish. To change the language, press  the Language button on the top of the monitor.  English language will display L1 4.  When just the letters “oFF” appear, the monitor is  in “Quiet Mode”. Spanish language will display L2 17 18 B BPW-260_A.indd   17-18 PW-260_A.indd   17-18 1 12/7/09   4:48 PM 2/
                    
                    Summary of the content on the page No. 11 
                    
                        5.  If your physician has diagnosed  APPLYING THE CUFF Fig. D you with poor circulation in your  1.  Remove all watches, wrist jewelry, etc. prior to  left arm, place the cuff around  attaching the wrist monitor. Clothing sleeves should  your right wrist as shown in  be rolled up and the cuff should be wrapped  Fig. D. around bare skin for correct measurements. 2.  Apply cuff to left wrist with palm  Fig. A facing up as shown in Fig. A. CORRECT MEASUREMENT POSTURE 3.  Make sure the edge of the c
                    
                    Summary of the content on the page No. 12 
                    
                        4.  Sit upright in a chair, and take 5-6 deep breaths. �  Before a measurement, it is suggested that you sit  quietly for 15 minutes as measurements taken during  Avoid leaning back while the a relaxed state will have greater accuracy. You should  Fig. C measurement is being taken as not be physically tired or exhausted while taking a  shown in Fig. C. measurement. (X) �  During the measurement, do not talk or move your  arm or hand muscles. �  See page 31 for additional notes regarding your  bl
                    
                    Summary of the content on the page No. 13 
                    
                        2.   With the cuff wrapped around your wrist, press the   Note:  The monitor will re-inflate automatically if the  START/STOP button. Do not inflate the cuff unless  system detects that your body requires more  it is wrapped around your wrist. All digits will light  pressure for measurement. up, checking the display functions. The checking  procedure will be completed after about 3 seconds. START STOP Note: If using the Voice Assist™ “Instructions On”  mode, you will be prompted to press the  ST
                    
                    Summary of the content on the page No. 14 
                    
                        Note: RISK CATEGORY INDEX 1.  This monitor automatically turns off approximately  This monitor comes equipped with a Risk  1 minute after last operation. You may also press  Category Index that automatically compares each  the START/STOP button to turn the unit off. reading to criteria established by the U.S. National  Institute of Health’s (NIH) National Heart Lung and  2.  To interrupt the measurement, you may press  Blood Institute as described earlier in this manual,  the START/STOP button (
                    
                    Summary of the content on the page No. 15 
                    
                        IMPORTANT INFORMATION: IRREGULAR HEARTBEAT  This blood pressure monitor is not designed for use  DETECTOR (IHB) by people with arrhythmias nor for diagnosing or  The appearance of the  icon indicates that a pulse  treating an arrhythmia problem.  As a safeguard, we  irregularity consistent with an irregular heartbeat was  recommend that if you have arrhythmias such as atrial  detected during measurement.  Usually this is not a cause  or ventricular premature beats and atrial fibrillation  for co
                    
                    Summary of the content on the page No. 16 
                    
                        3.  Press the “M” button to access the memory. CLEARING VALUES FROM MEMORY M 1.    Press the User-Select button to select User 1 or  User 2. 4.  The monitor will first display the calculated average  applied to the last 3 memories (“AVG. 3”).  2.    Press and hold the    and    buttons at the same  time while in memory recall mode and the data for  the selected user will be erased automatically. and 5.  Every new press of the “M” button will recall  a previous reading. The latest reading will be
                    
                    Summary of the content on the page No. 17 
                    
                        �   Once inflation reaches 300 mmHg, the unit will  IMPORTANT NOTES REGARDING YOUR  deflate automatically for safety reasons. BLOOD PRESSURE MEASUREMENT �   This product is not suitable for people with  �  T ake your reading in a comfortable environment  arrhythmias.   as measurements can be affected by hot or cold  �  This device may have difficulty determining the  temperatures. Take your blood pressure at normal  proper blood pressure for users with irregular  body temperature. heartbeat, dia
                    
                    Summary of the content on the page No. 18 
                    
                        7.   Do not fold the cuff tightly. CARE, MAINTENANCE & CLEANING 8.    Do not disassemble the monitor or cuff.  If in  1.    Clean the blood pressure monitor body and cuff  need of repair, refer to the warranty section of this  carefully with a slightly damp, soft cloth. Do not  manual. press. Do not wash cuff or use chemical cleaner on  it. Never use thinner, alcohol or petrol (gasoline) as  9.    Do not subject the monitor to extreme shocks (do  cleaner. not drop on floor). 2.    Leaky batterie
                    
                    Summary of the content on the page No. 19 
                    
                        POTENTIAL FOR ELECTROMAGNETIC TROUBLESHOOTING If any abnormality arises during use, please check the following points: INTERFERENCE  POSSIBLE  To avoid inaccurate results caused by  SYMPTOMS CORRECTION CAUSES electromagnetic interference between  Unit does not Batteries have Replace them  electrical and electronic equipment,  turn on when the run down. with two new AAA  do not use the device near a cell  START/STOP alkaline batteries. phone or microwave oven.  button is pushed. Battery polaritie
                    
                    Summary of the content on the page No. 20 
                    
                        SPECIFICATIONS SPECIFICATIONS (continued) Power Source: Two 1.5V DC (AAA) Alkaline batteries  Weight: 0.30 lbs (136.2 g) (without batteries) Measurement  Wrist  Oscillometric 5.3” - 7.7” (13.5cm - 19.5cm) Method: Circumference: Measurement Pressure:  40~280 millimeters Mercury (mmHg) 2 AAA alkaline batteries, hard plastic  Accessories: Range: Pulse: 40~199 beats/minute storage case Pressure: ±3 mmHg 3.4”(L) x 2.5”(W) x 1.3”(H) Accuracy: Dimensions: Pulse: ±5% of reading 85mm(L) x 64mm(W) x 33mm(