Summary of the content on the page No. 1 
                    
                        ELECTRIC DRYER INSTALLATION INSTRUCTIONS
29" WIDE MODELS - U.S.A. ONLY
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite:  
www.whirlpool.com 
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta. 
Table of Contents
DRYER SAFETY ......................................................................... 2
INSTALLATION REQUIREMENTS ..............
                    
                    Summary of the content on the page No. 2 
                    
                        DRYER SAFETY 2                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    Summary of the content on the page No. 3 
                    
                        3                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   
                    
                    Summary of the content on the page No. 4 
                    
                        INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation.  Read and follow the instructions provided with any tools listed here. Tools needed:  Level Caulking gun and  compound (for installing  new exhaust vent) Parts supplied (all models):  Flat-blade screwdriver #2 Phillips screwdriver Leveling legs (4) Parts package is located in dryer drum. Check that all parts   Wire stripper  Tin snips  are included. (direct wire installations) (new vent in
                    
                    Summary of the content on the page No. 5 
                    
                        Minimum spacing for recessed area or closet  Location Requirements installation The dimensions shown following are for the minimum spacing  allowed. ■ Additional spacing should be considered for ease of  installation and servicing. ■ Additional clearances might be required for wall, door, and  floor moldings. ■ Additional spacing of 1" (25 mm) on all sides of the dryer   is recommended to reduce noise transfer. ■ For closet installation, with a door, minimum ventilation  openings in the top and 
                    
                    Summary of the content on the page No. 6 
                    
                        If your outlet looks like this: Electrical Requirements Then choose a 4-wire power supply cord with  ring or spade terminals and UL listed strain  It is your responsibility: relief. The 4-wire power supply cord, at least   ■ To contact a qualified electrical installer. 4 ft. (1.22 m) long, must have 4 10-gauge solid  copper wires and match a 4-wire receptacle of  ■ To be sure that the electrical connection is adequate and in  NEMA Type 14-30 R. The ground wire (ground  conformance with the Natio
                    
                    Summary of the content on the page No. 7 
                    
                        Install Leveling Legs Electrical Connection Power Supply Cord 1.  Prepare dryer for leveling legs To avoid damaging floor, use a large flat piece of cardboard  from dryer carton; place under entire back edge of dryer.  Firmly grasp dryer body (not console panel) and gently lay  dryer down on cardboard. Electrical Connection Options 2.  Screw in leveling legs 1. Choose electrical connection type diamond Power supply cord 4-wire receptacle marking (NEMA Type 14-30R): Go to steps 1-2 on  page 9 for
                    
                    Summary of the content on the page No. 8 
                    
                        Direct Wire Power Supply Cord Connection Power supply cord strain relief     Attach power supply cord   1.      strain relief A B C D Remove the screws from a 3/4" (19 mm) UL listed strain relief  (UL marking on strain relief). Put the tabs of the two clamp  sections (C) into the hole (B) below the terminal block opening  so that one tab is pointing up (A) and the other is pointing  down (D), and hold in place. Tighten strain relief screws just  enough to hold the two clamp sections (C) together
                    
                    Summary of the content on the page No. 9 
                    
                        4-wire Power Supply Cord Connection 5. Connect ground wire IMPORTANT: A 4-wire connection is required for mobile  homes and where local codes do not permit the use of 3-wire  A connections.  BF A E C D G A. 4-wire receptacle (NEMA type 14-30R) B. 4-prong plug C. Ground prong F D. Neutral prong E. Spade terminals with upturned ends F. 3/4" (19 mm) UL listed strain relief Connect ground wire (F) (green or bare) of power supply cord   G. Ring terminals to external ground conductor screw (A). Tighte
                    
                    Summary of the content on the page No. 10 
                    
                               5" (127 mm) 2. Attach direct wire cable to  4. Connect neutral wire  strain relief  B C Put direct wire cable through the strain relief. The strain relief  Connect neutral wire (white or center) (C) of power supply cord  should have a tight fit with the dryer cabinet and be in a  to center terminal block screw (B). Tighten screw. horizontal position. Tighten strain relief screws. For 3-wire Direct Wire Connection, see page 11. 5. Connect remaining wires For 4 wire Direct Wire Connection, 
                    
                    Summary of the content on the page No. 11 
                    
                            3½" (89 mm) 8. Connect remaining wires 5. Prepare to connect neutral       ground wire and neutral wire A B E Place hooked ends of remaining direct wire cable wires under  outer terminal block screws (hooks facing right). Squeeze hooked  ends together and tighten screws. Finally, reinsert tab of terminal  block cover into slot of dryer rear panel. Secure cover with hold- down screw. Now, go to Venting Requirements.  Remove center  terminal block screw (B). Remove neutral  ground wire (E) fro
                    
                    Summary of the content on the page No. 12 
                    
                        6. Connect neutral wire 2. Connect neutral ground wire  and neutral wire B C C E Place hooked end of neutral wire (white or center) (C) of direct  wire cable under center terminal block screw (B). Squeeze  hooked end together. Tighten screw. Connect neutral ground wire (E) and neutral wire (white or  center wire) (C) of power supply cord or cable under center  7. Connect remaining wires terminal block screw (B). Tighten screw. 3. Connect remaining wires Place hooked ends of remaining direct wire
                    
                    Summary of the content on the page No. 13 
                    
                        VENTING Venting Requirements Exhaust hoods: ■ Must be at least 12" (305 mm) from ground or any object that  may obstruct exhaust (such as flowers, rocks, bushes, or  snow). Recommended Styles: Louvered hood Box hood Acceptable Style: WARNING: To reduce the risk of fire, this dryer MUST BE  EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent,  Angled hood chimney, wall, ceiling, attic, crawlspace, or a concealed space  o
                    
                    Summary of the content on the page No. 14 
                    
                        Alternate installations for close clearances Plan Vent System Venting systems come in many varieties. Select the type best  for your installation. Two close-clearance installations are shown.  Recommended exhaust installations Refer to the manufacturer’s instructions. Typical installations vent the dryer from the rear of the dryer.  Other installations are possible. B C D E F A G Over-The-Top installation (also available with one offset elbow) B H A. Dryer E. Clamps B. Elbow F. Rigid metal or fl
                    
                    Summary of the content on the page No. 15 
                    
                        Special provisions for mobile home installations: Vent System Chart The exhaust vent must be securely fastened to a noncombustible  portion of the mobile home structure and must not terminate (Long Vent Models Only) beneath the mobile home. Terminate the exhaust vent outside. Number of Type  Box/louvered, or   90° turns  of vent Angled hoods or elbows 0 Rigid metal 120 ft. (36.6 m) 1 Rigid metal 110 ft. (33.5 m) 2 Rigid metal 100 ft. (30.5 m) Rigid metal 90 ft. (27.4 m) 3 4 Rigid metal 80 ft. (2
                    
                    Summary of the content on the page No. 16 
                    
                        NOTE: The dryer must be level for the moisture sensing system  Connect Vent to operate correctly. 1. Connect vent to exhaust outlet        Not Level             LEVEL                    Not Level Tighten and adjust leveling legs 2.  Using a 4" (102 mm) clamp, connect vent to exhaust outlet   in dryer. If connecting to existing vent, make sure vent is  clean. Dryer vent must fit over dryer exhaust outlet and inside  exhaust hood. Check that vent is secured to exhaust hood  with a 4" (102 mm) clam
                    
                    Summary of the content on the page No. 17 
                    
                         When the dryer has been running for 5 minutes, open the  q 3. Lift door off top screws dryer door and feel for heat. If you feel heat, cancel cycle and  close the door. If you do not feel heat, turn off dryer, and check the  following: ■ There may be 2 household fuses or circuit breakers for  the dryer. Check that both fuses are intact and tight, or  that both circuit breakers have not tripped. If there is still  no heat, contact a qualified technician. NOTE: You may notice an odor when the dry
                    
                    Summary of the content on the page No. 18 
                    
                        6. Flip door over Switch door catch, bezel, & plug 8. Plug Catch and bezel Flip door over so handle side is down.  9. Attach door hinges Remove the door catch, bezel, and plug from the inside of  the inner door by squeezing and pulling/pushing them. Place  the door catch, bezel, and plug on the sides opposite from  where they were. 7. Rotate outer door Rotate outer door 180º and set it back down on inner door.  Reattach outer door panel to inner door panel so handle is  on the side where hinges 
                    
                    Summary of the content on the page No. 19 
                    
                        10. Remove door strike and  12. Insert screws in hinge holes on   door strike plug dryer cabinet Door strike Door strike plug Remove door strike and door strike plug from dryer cabinet.  NOTE: Two people may be needed to reinstall door. Insert the door strike into door strike plug hole and secure  with screw. Insert door strike plug into original door strike  Insert screws into the bottom holes on left side of dryer  hole and secure with screw. cabinet. Tighten screws halfway. Position door so l
                    
                    Summary of the content on the page No. 20 
                    
                        ®/™ ©2013 Whirlpool. All rights reserved. 01/13  W10514172A  Printed in U.S.A.  W10514174A-SP