Summary of the content on the page No. 1 
                    
                        DO NOT
DISCARD
R
Owner’s Manual
Installation and Operation
Model:
QV36DC-A
CAUTION
DO NOT DISCARD THIS MANUAL
Important operating and 
Read, understand and follow Leave this manual with 
••
•
maintenance instruc- these instructions for safe party responsible for use 
tions included. installation and operation. and operation.
WARNING
WARNING:  If the information in these 
HOT SURFACES! 
instructions is not followed exactly, a fi re 
Glass and other surfaces are hot during 
or explosion may result 
                    
                    Summary of the content on the page No. 2 
                    
                        SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems  READ and UNDERSTAND all instructions carefully  ! ! described in the Installing the Fireplace section of  before starting the installation. FAILURE TO  the Owner’s Manual. NO OTHER vent systems or  FOLLOW these installation instructions may result in  components MAY BE USED. a possible fi re hazard and will void the warranty. This gas fi replace and vent assembly MUST be  Prior to the fi rst fi ring of the fi replace, READ t
                    
                    Summary of the content on the page No. 3 
                    
                        TABLE OF CONTENTS Safety and Warning Information .................................................2 Service Parts Lists .......................................................................4 Section 1: Approvals and Codes ................................................7 Appliance Certifi cation ....................................................................7 Installation Codes ...........................................................................7 High Altitude Installations ........
                    
                    Summary of the content on the page No. 4 
                    
                        Approvals and  Codes 1 Appliance Certifi cation High Altitude Installations  The  fi replace model discussed in this Owner’s Manual  U.L. Listed gas appliances are tested and approved without  has been tested to certifi cation standards and listed by the  requiring changes for elevations from 0 to 2,000 feet in the  applicable laboratories. U. S. A. and in Canada. When installing this appliance at an elevation above 2,000  Certifi cation feet, it may be necessary to decrease the input rating by  cha
                    
                    Summary of the content on the page No. 5 
                    
                        Inspection Note: The following requirements reference various  The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this  tally vented gas fueled equipment shall not approve the  document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed  Requirements for the Commonwealth of  in accordance with the provisions of 248 CMR 5.08(2)(a)1  Massachusetts through 4.  For all side wall hor
                    
                    Summary of the content on the page No. 6 
                    
                        Getting Started 2 Introducing Quadra-Fire Gas Fireplaces The Hearth & Home Technologies Warranty will be voided  by, and Hearth & Home Technologies disclaims any  Quadra-Fire direct vent gas fi replaces are designed to op- responsibility for, the following actions: erate with all combustion air siphoned from outside of the  • Installation of any damaged fi replace or vent system  building and all exhaust gases expelled to the outside.  component. The information contained in this Owner’s Manual, u
                    
                    Summary of the content on the page No. 7 
                    
                        28 1/2 [724mm] 14 1/4  [362mm] 21 1/2 [548mm] 8 5/8 [219mm] 11 5/8 [297mm] VENT COLLARS 8 5/8 ELECTRICAL [219mm] ACCESS VENT COLLARS GAS LINE ACCESS 34 5/8 38 25 1/4 [879mm] [965mm] [642mm] 26 7/8 2 1/8 3 1/2 [682mm] [55mm] [90mm] 36 1/8 [916mm] 12 3/4 [323mm] 6 7/8 [174mm] 41 1/8 [1044mm] TOP STANDOFFS HOOD RATING PLATE AND LABELS ELECTRICAL GAS ACCESS LINE ACCESS GAS CONTROLS Figure 1. Diagram of the QV36DC-A 10 Quadra-Fire  •  QV36DC-A  •  2161-900 Rev. C  •  6/09                             
                    
                    Summary of the content on the page No. 8 
                    
                        1” MIN. (25mm) B A Installing the Fireplace 3 Constructing the Fireplace Chase A chase is a vertical box-like structure built to enclose the  gas fi replace and/or its vent system. Vertical vents that run  on the outside of a building may be, but are not required  D E to be, installed inside a chase. C CAUTION: TREATMENT OF FIRESTOP SPACERS AND  CONSTRUCTION OF THE CHASE MAY VARY WITH THE  1/2” MIN. (13mm) TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT   A B C D E SUBSTITUTES FOR THE REQUIREMENTS O
                    
                    Summary of the content on the page No. 9 
                    
                        Step 2.  Framing the Fireplace CAUTION: MEASURE FIREPLACE DIMENSIONS AND  Fireplace framing can be built before or after the fi replace is  VERIFY FRAMING METHODS AND WALL COVERING  set in place. Framing should be positioned to accommodate  DETAILS BEFORE FRAMING. wall coverings and fi replace facing material. The diagram  below shows framing reference dimensions. Noncombustible zone is defined by 3” above the elbow for the entire width and depth (behind the front header) of the firebox. WALL STUD
                    
                    Summary of the content on the page No. 10 
                    
                        DVP90ST 4 6 12 DVP4 DVP6 DVP12 14-1/4 12-3/16 2 MAX. MIN. 24 36 DVP12A 48 9-7/8 DVP24 45.0 10-1/4 DVP45 DVP36 11-1/4 7-1/4 1-1/4 TYP DVP48 1/2 TYP 8-9/16 12-9/16 NOTE:  PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT.  Figure 4.  DVP-Series Direct Vent Component Specifi cations  (5-inch inner pipe / 8-inch outer pipe) Quadra-Fire  •  QV36DC-A  •  2161-900 Rev. C  •  6/09 13                                                                                                                                    
                    
                    Summary of the content on the page No. 11 
                    
                        Step 3.  Installing the Vent System Identifying Vent Components  A.  Vent System Approvals The vent systems installed on this gas fi replace may include    one, two, or three 90° elbow assemblies. The relationships  This model is approved to use DVP-series direct vent  of vertical rise to horizontal run in vent confi gurations using  pipe components and terminations (see Figures 4 and 5).  90° elbows MUST BE strictly adhered to. The rise to run  Approved vent system components are labeled for iden
                    
                    Summary of the content on the page No. 12 
                    
                        CAP STRAIGHT UP VERTICAL VENTING V (FT.) 40’ MAX. (12.4 M) NOTE: On vertical vent- V ing confi gurations over  20 feet install the fl ue re- ADJUSTABLE FLUE strictor  (2027-102). See  RESTRICTORS (2) Figure 7.   fl ue restrictor installation  instructions. - CHART - Vertical Top Vent Top Vent Rear Vent Rear Vent  NG LP NG LP 4’ 2-2 2-3 No No  Restrictor Restrictor 8’ 3-3 2-3 2-2 No  Restrictor 15’ 3-4 3-4 3-3 2-3 20’ 4-4 3-4 3-4 3-4 25’ 4-4 3-4 3-4 3-4 30’ 4-4 4-4 4-4 3-4 35’ 4-4 4-4 4-4 3-4 40’ 4-
                    
                    Summary of the content on the page No. 13 
                    
                        HORIZONTAL VENTING 90-DEGREE Kit No. H Max. Run ELBOWS DVP-TRAP 24” (610 mm) H 45-DEGREE ELBOW Figure 9. Horizontal Installation NOTE: This model is tested and approved to use  45° elbows in corner installations. However, 90°  elbows will result in better performance. Figure 10. Corner Installation 16 Quadra-Fire  •  QV36DC-A  •  2161-900 Rev. C  •  6/09                                                                                                                                                
                    
                    Summary of the content on the page No. 14 
                    
                        VENTING WITH ONE (1) 90° ELBOW        V         H    1’ MIN. (305mm)  2’   MAX.  (610mm)    2’ MIN. (610mm)  4’   MAX.  (1.22m)    3’ MIN. (914mm)  6’   MAX.  (1.86m)    4’ MIN. (1.22m)  8’   MAX.  (2.4m)      V+H=40’ MAX. (12.4m)      H = 8’ MAX.  (2.4m)  NOTE: On vertical venting configurations  where the vertical component is over 10 feet  V install the vertical baffl e included in the manual  bag assembly to improve fl ame appearance. H Figure 11. Venting with One 90° Elbow VENTING WITH ONE (1
                    
                    Summary of the content on the page No. 15 
                    
                        VENTING WITH TWO (2)  90° ELBOWS H 1 V H V H  H + H 1  1´ MIN. (305 mm) 2´ MAX. (610 mm)  5´  MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2m) V+H+H1 = 40´ MAX. (12.4 m)      H = 8´ MAX. (2.48 m)       H+H = 20´ MAX. (6.2m) 1  Figure 13. Venting with Two 90° Elbows o VENTING WITH TWO (2) 90 ELBOWS    V FT.        H + H (FT.) 1 1’  MIN. (305mm)    5´ MAX. (1.52m) 2’  MIN. (610mm)  10
                    
                    Summary of the content on the page No. 16 
                    
                        VENTING WITH THREE (3) 90° ELBOWS V                           H                              H + H 1  1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m) 4´MIN. (1.22m) 8´MAX. (2.48m) 20´MAX. (6.2m) V +V+H+H = 40´ MAX.(12.4 m)  H = 8´MAX.(2.48 m)  H+H = 20´MAX.(6.2 m) 1 1 1 V 1 V H 1 H   V H H + H + H 1 2  1´MIN. (305mm) 2´MAX. (610mm)   5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6
                    
                    Summary of the content on the page No. 17 
                    
                        VENTING WITH THREE (3) 90° ELBOWS H 1 V 1 V H  V (FT.)         H (FT.)   1’  MIN.  (305mm)   5’ MAX. (1.52m)   2’  MIN. (610mm) 10’ MAX. (3.1m)   3’  MIN. (914mm) 15’ MAX. (4.65m)   4’  MIN. (1.22m)  20’ MAX. (6.2m)        NOTE:   H + H = 20’ MAX. (6.2m) 1  V + V + H + H = 40’ MAX. (12.4m)  1 1 V 1 H 1 V H  V (FT.)                H  + H (FT.) 1  1’  MIN. (305mm) 5’ MAX. (1.52m) 2’  MIN. (610mm) 10’ MAX. (3.1m) 3’  MIN. (914mm) 15’ MAX. (4.65m) 4’  MIN. (1.22m)  20’ MAX. (6.2m)         H +H = 20’
                    
                    Summary of the content on the page No. 18 
                    
                        B.  Installing Vent Components  WARNING: YOU MUST LEAVE THE INSULA- ! After determining which set of starting collars will be used  TION IN PLACE IN THE SET OF COLLARS  (top or rear), follow venting instructions accordingly. YOU ARE NOT USING. Venting Out the Rear Vent If your vertical vent component is over 10 feet, you may  Remove the installed rear seal cap from the rear starting  want to install the included vertical baffl e to improve fl ame  collars by cutting the strap at each end. (see Fig
                    
                    Summary of the content on the page No. 19 
                    
                        • If the combustible materials are not in place at the time  To Install the Heat Shield: of install the elbow heat shield may be screwed to the  1. Determine if the heat shield is required. Do so by mea- exhaust pipe (see Figure 21). Cut the tabs as shown and  suring the vertical distance between the top horizontal  bend down. Secure the heat shield to the pipe maintain- surface of the elbow to any combustible surface above.  ing 3” to 4” between the pipe and shield.  If the distance is more tha
                    
                    Summary of the content on the page No. 20 
                    
                        5.  Install Firestops For Horizontal Runs - Firestops are REQUIRED on  both sides of a combustible wall through which the vent  10 in. passes. INTERIOR WALL SHIELD NOTE: Model DVP-TRAP does not need an exterior  fi restop on an exterior combustible wall. To install fi restops for horizontal runs that pass through  either interior or exterior walls: 12 in. •  Cut a 10-inch by 12-inch (254mm X 305mm) hole through  the wall.  NOTE: The center of the hole is one (1) inch (25.4mm)  above the center of