Summary of the content on the page No. 1 
                    
                        Riva Open Log Burning
Convector Fireboxes
16", 22", 24", 26" & 28" Standard and Low models
Instructions for Use,
Installation and Servicing
For use in Great Britain and Republic of Ireland.
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated 
instructions and in some cases the appliance will require modification. Contact Stovax for further information.
IMPORTANT
This appliance will 
                    
                    Summary of the content on the page No. 2 
                    
                        COVERING THE FOLLOWING MODELS:                                       8610/8611/8604/8605/8606/8607/8608/8609/8673   APPLIANCE COMMISSIONING CHECKLIST    3 COMMISSIONING 27 USER INSTRUCTIONS 4 MAINTENANCE & SERVICING 28 General Points 4 Annual Service 28 Using the Appliance for the first time 5 Removal of Flue Damper 28 Recommended Fuels 5 Lighting the appliance 6 Running the appliance 6 SERVICE RECORDS 30 Burning Tips 7 Ash Removal 8 EC DECLARATION OF CONFORMITY 31 Extended burning 9 Over-Firing
                    
                    Summary of the content on the page No. 3 
                    
                        APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information:- Dealer appliance was purchased from Name: ..................................................................................................................................................................................... Address: .........................................................................................................................................................
                    
                    Summary of the content on the page No. 4 
                    
                        USER INSTRUCTIONS 1.12 To access the data plate: 1. GENERAL POINTS  If a Contemporary Steel Frame is fitted, lift the frame off,  see Installation Instructions Section 3 Fitting Of Frames. 1.1 Before use of this appliance please read these  instructions fully.   If fitted remove multi-fuel kit or log tray before lifting out    the base plate, see Installation Instructions Section 2 Fitting  1.2 All local regulations, including those referring to national  Of Fuel Kits. and European Standards nee
                    
                    Summary of the content on the page No. 5 
                    
                        USER INSTRUCTIONS  Poor quality timber:  — Causes low combustion efficiency  WARNING  — Produces harmful condensation  —  Reduces effectiveness of the airwash and life of the   Properly installed operated and maintained this  appliance  appliance will not emit fumes into the room.    Do not burn construction timber, painted, impregnated   Occasional fumes from de-ashing and refuelling may occur. / treated wood, manufactured board products or pallet  wood.     Persistent fume emission is potentia
                    
                    Summary of the content on the page No. 6 
                    
                        USER INSTRUCTIONS 4. LIGHTING THE APPLIANCE 5. RUNNING THE APPLIANCE 4.1 For best results: 5.1 Burning Wood:   	 •	 S e t 	 d a m p e r 	 c o n t r o l s , 	 S e e 	 D i a g r a m 	 6  To burn wood it is required to fit a log box as listed:  Riva Open 16" 22" 24" 26" 28" Cassette Product Code Std 8610/ 8604/ 8606/ 8608/ 8673 Product Code Low 8611 8605 8607 8609 Holyrood Black 8627 8628 8629 8630 Holyrood Polished 8627P 8628P 8629P 8630P Open Castle 8623 8624 8625 Portcullis 8678 8666 8667 8668 8
                    
                    Summary of the content on the page No. 7 
                    
                        USER INSTRUCTIONS  The multi-fuel kit is fitted as shown: 5.7 De-ash the fire bed before re-fuelling, See Section 7 Ash  Removal  Note that this kit must only be used with the appropriate  Steel frame, Diagram 10. 	 •	 Burn	 new	 fuel	 at	 high	 output	 for	 a	 few	 minutes	 before	 adjusting the Air Damper control* to the desired setting  	 •	 Refuel	 little	 and	 often	 for	 clean, 	 efficient	 burning. 5.8 Experience establishes control settings to suit personal  preferences 5.9 Do not burn l
                    
                    Summary of the content on the page No. 8 
                    
                        USER INSTRUCTIONS  — Smoke and small flames 	 •	 Fit	 a	 rain	 cowl	 to	 the	 chimney  — Short life span for grate  Your installer should advise you on possible solutions.  If the appliance emits smoke into the room continuously:  6.3 Flue Draught 	 •	 Allow	 the	 appliance	 to	 go	 out  The chimney has two main functions: 	 •	 Ventilate	 the	 room	 to	 clear	 the	 fumes  1) To safely remove the smoke, gases and fumes from the  house.  Do not re-light the appliance until the problem is solved.  
                    
                    Summary of the content on the page No. 9 
                    
                        USER INSTRUCTIONS  •	 Use	 smokeless	 fuel	 or	 small,	 thick	 logs	 depending	 on	 fuel	 desired Poker 9. OVER-FIRING 9.1 Do not over-fill with fuel or use at maximum output for  long periods or over-firing can occur. If the flue pipe, flue  collar or top plate glow red the appliance is over-firing:  •	Close the Air Damper (Primary if multi-fuel kit fitted)  control to reduce the output 9.2 Over-firing can cause permanent damage to the appliance.   PR8074 10. CHIMNEY FIRE 7.3  Remove components
                    
                    Summary of the content on the page No. 10 
                    
                        USER INSTRUCTIONS Your retailer can provide genuine spare parts when required. An  13. CHIMNEY SWEEPING annual service by a competent engineer is recommended to keep  your appliance in best possible condition. 13.1 To maintain safe and efficient use of the appliance the  chimney/flue must be inspected and swept at least once a  year by a qualified chimney sweep.*  If the appliance is used continuously throughout the year  or it is used to burn wood or smokeless fuel, more frequent  sweeping is r
                    
                    Summary of the content on the page No. 11 
                    
                        TECHNICAL SPECIFICATION RIVA OPEN Model 4 6.5 8 9 10 Wood kW Nominal Heat Output 3 4 5 5 5 Solid Fuel kW 1.25 1.25 1.25 1.25 1.25 mm Flue Draught at Nominal Heat All Fuels 0.05 0.05 0.05 0.05 0.05 inch Wg 39.1 45.0 52.8 53.0 54.1 Wood g/s Flue Gas Mass Flow 27.8 30.0 75.1 45.0 49.5 Solid Fuel g/s 200 155 165 180 220 Wood °C Flue Gas Temperature at Spigot/Socket 110 125 120 150 150 Solid Fuel °C 2x(120x102) 3x(105x105) 3x(122x105) 3x(138x105) 3x(138x105) mm Flue Outlet Size 3 1 1 13 1 7 1 7 1 2x(
                    
                    Summary of the content on the page No. 12 
                    
                        TECHNICAL SPECIFICATION RIVA OPEN DIMENSIONS A C E B D PR8100 16" Low 22" Low 24" Low 26" Low 28" A 474 474 624 624 674 674 724 724 774 B 592 542 652 592 652 592 652 592 652 C 348 348 348 348 348 348 348 348 348 D 550 500 610 550 610 550 610 550 610 E 400 400 550 550 600 600 650 650 700 F 489 489 639 639 689 689 739 739 789 G 595 545 655 595 655 595 655 595 655 H 16 16 16 16 16 16 16 16 16 J 481 - - - - - - - - K 595 - - - - - - - - L 32 - - - - - - - - M Square - - 765 - - - 865 - - M Rectangul
                    
                    Summary of the content on the page No. 13 
                    
                        TECHNICAL SPECIFICATION RIVA OPEN DIMENSIONS PROFIL ARTS STEEL SQUARE/RECTANGULAR M SQUARE/RECTANGULAR P H L F J G K PR8100 PROFIL ARTS 16" 22" 24" 26" 28" 16" 22" 24" 26" 28" Profil Brass -  8633 8635 8637 8639 8626 Arts Frame 8700 - - - - standard height Profil Brass -  STEEL 8674 8636 8638 8640 - low lintel 16" 22" 24" 26" 28" Profil Brushed  Stainless - 8633BS 8635BS 8637BS 8639 8626BS standard height Steel Frame -  8730 8732 - 8736 - Rectangular Profil Brushed  Stainless - 8674BS 8636BS 863
                    
                    Summary of the content on the page No. 14 
                    
                        SITE REQUIREMENTS 1.5 You must sweep and inspect the flue when the appliance is  1. FLUE OR CHIMNEY installed. 1.6 You must check the flue draught with all windows and  1.1 The flue or chimney system must be in good condition. doors closed and any extraction fans in this or adjoining   It must be inspected by a competent person and passed for  rooms running at maximum speed. (See next section for  use with the appliance before installation additional ventilation requirements)  Products of combus
                    
                    Summary of the content on the page No. 15 
                    
                        SITE REQUIREMENTS 2. FLUE OUTLET POSITIONS IMPORTANT: Seek specialist  advice if installing in a dwelling  with a thatched roof Horizontal  Terminal Measurement Flue 150mm  Vertical  max Measurement Adjacent  Building Insulation The vertical measurement is the lowest from either the  point of discharge or 150mm above insulation. Position On Roof Minimum Clearances On ridge or within 600mm 600mm above ridge A Elsewhere on roof 2300mm horizontally from roof surface and: B a) 1000mm above highest p
                    
                    Summary of the content on the page No. 16 
                    
                        SITE REQUIREMENTS 4.2 The structure of the builders opening will reach high  4. BUILDERS OPENING temperatures. Use insulating blockwork to reduce the heat  transfer to the external walls, in particular the area of the  chimney breast above the opening.  To make installation easier make the opening larger than  the minimum requirements where possible. 4.3 Take care when finishing the chimney breast and  surrounding area. The conducted and convected heat  emitted by the appliance could be high eno
                    
                    Summary of the content on the page No. 17 
                    
                        PRE-INSTALLATION CHECKS 1. VENTILATION Model mm 200 200 200 200 200 Without liner system (round)  minimum dimension (diameter.) inch 8 8 8 8 8 mm 185 185 185 185 185 Without liner system (square)   Flue/Chimney Size minimum dimension inch 7 1/4 7 1/4 7 1/4 7 1/4 7 1/4 Liner or factory made system  mm 200 200 200 200 200 (diameter.)  inch 8 8 8 8 8 installed in accordance with manufacturers instructions Do not connect to systems containing large voids or over 9" (230mm) square/round m 4.5 4.5 4.5
                    
                    Summary of the content on the page No. 18 
                    
                        PRE-INSTALLATION CHECKS 2. ADDITIONAL VENTILATION 2.2 Extractor fans or cooker hoods should not be placed in the  2.1  Open appliances require additional ventilation to comply  same room or space as the appliance. with the requirements of the Building Regulations. This  should be provided using a permanently open air vent, of  2.3  If any of these checks reveal problems do not proceed  the size listed, which is positioned so that it is not liable to  with the fitting of the appliance until they 
                    
                    Summary of the content on the page No. 19 
                    
                        INSTALLATION INSTRUCTIONS 1 LEGAL REQUIREMENTS Before installation of this product please read these  instructions fully. It is very important to understand the requirements of the national  Building Regulations* and standards**, along with any local  regulations and working practices that may apply. Should any  conflict occur between these instructions and these regulations  then the regulations must apply. Your local Building Control Office can advise regarding the  requirements of the regulat
                    
                    Summary of the content on the page No. 20 
                    
                        INSTALLATION INSTRUCTIONS 	 •	 Lift	 over	 frame 3 6 PR8079 2A. FITTING OF FUEL KITS - LOG PR8073 2.1 Install the relevant fuel box. 2.4  Fit the Contemporary Log Bar, Diagram 7    4 	 •	 Slide	 into	 channels	 in	 front	 of	 the	 logbox	  The removable frame plate is not shown for clarity but must  be in place before the Log Bar is fitted, See Section 3A. 7 PR8080 2.2  Fit the Log Retainer (Holyrood, Castle, Portcullis),  Diagram 5.   Note: the Holyrood retainer has a specially curved log- PR80