Summary of the content on the page No. 1 
                    
                        www.regency-fi re.com
ULTIMATE U37 Rear Vent 
Owners & 
Direct Vent Freestanding Gas Stove
Installation Manual
MODELS:     U37-NG1 Natural Gas     U37-LP1 Propane
WARNING:  FOR YOUR SAFETY
If the information in these instructions are not followed ex- What to do if you smell gas:
actly, a fi re or explosion may result causing property damage,  Do not try to light any appliance
 Do not touch any electrical 
personal injury or loss of life. 
switch: do not use any phone in 
FOR YOUR SAFETY
your build
                    
                    Summary of the content on the page No. 2 
                    
                        To the New Owner: Congratulations!  You are the owner of a state-of-the-art ULTIMATE Rear Vent Direct Vent Gas Stove by FPI Fireplace  ® Products International. The Regency Gas Series of hand crafted appliances has been designed to provide you with  all  the warmth and charm of a woodstove, at the fl ick of a switch.  The models U37-NG1, and U37-LP1 of this series  has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to  provide you with e
                    
                    Summary of the content on the page No. 3 
                    
                        TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Copy of Serial No. Decal ...............................................4 Operating Instructions .................................................25 Lighting Procedure ......................................................25 Shutdown Procedure ...................................................25 REQUIREMENTS  First Fire ......................................................................25 Convection Fan Operation .........................
                    
                    Summary of the content on the page No. 4 
                    
                        Model/Modele:  Model/Modele:  U37-NG1 U37-LP1 SAFETY LABEL ® This is a copy of the label that accompanies NOTE: Regency units are constantly being  each ULTIMATE Rear Vent Direct Vent Free- improved. Check the label on the unit and if  standing Gas Stove. We have printed a copy there is a difference, the label on the unit is the  of the contents here for your review. The safety correct one. label is located on the inside of the drop down  pedestal door.  Copy of Safety Label for U37 Listed:  GRA
                    
                    Summary of the content on the page No. 5 
                    
                        REQUIREMENTS  MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements:  (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for  residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than  seven (7) feet above finished gr
                    
                    Summary of the content on the page No. 6 
                    
                        INSTALLATION into a manufactured home the unit must be  DUE TO HIGH TEMPERATURES,  IMPORTANT MESSAGE   bolted down to the fl oor. THE APPLIANCE SHOULD BE  SAVE THESE  LOCATED OUT OF TRAFFIC AND  4) We recommend that you plan your instal- INSTRUCTIONS AWAY FROM FURNITURE AND  lation on paper using exact measurements  DRAPERIES. The ULTIMATE Rear Vent Direct Vent Freestand- for clearances and fl oor protection before  ing Gas Stove must be installed in accordance  actually installing this appliance.
                    
                    Summary of the content on the page No. 7 
                    
                        INSTALLATION 2) Ensure proper grounding using the #8 ground  INSTALLATION LOCATING YOUR  lug provided. CHECKLIST GAS STOVE 3) Appliance must be anchored to the fl oor with    the supplied anchoring methods.  1) Locate your appliance.  Refer to the following When selecting a location for your stove, ensure  sections: that the clearances listed above are met as well  as ensuring that there is adequate accessibility   a. Clearances to Combustibles for servicing and proper operation. CLEARANCES TO   
                    
                    Summary of the content on the page No. 8 
                    
                        INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS ® 8 U37-1 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) H= Not to be installed above a meter/regulator assembly within  B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) (3'/90cm) horizontally from the centerline of the regulator. C= Clearance to permanently closed window *(min. 12"/30cm) J= Clearance to service regulator vent outlet *(m
                    
                    Summary of the content on the page No. 9 
                    
                        INSTALLATION other safety hazards may result from any of the   IMPORTANT The gas appliance and vent system  following actions: must be vented directly to the outside  Read  all instructions carefully before starting  of the building, and never be attached  1) Installation of any damaged Direct Vent  the installation. Failure to follow these instruc- to a chimney serving a separate solid  component tions may create a fi re or other safety hazard,  fuel or gas-burning appliance. and will void the w
                    
                    Summary of the content on the page No. 10 
                    
                        INSTALLATION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed.  Not All Rigid Pipe components are available directly from FPI. Simpson  American Metal  ® Simpson Metal-Fab Security ® Selkirk  ® Direct Vent GS Description Products ® ® Direct Vent Pro Sure Seal Secure Vent Direct-Temp™ Amerivent Direct Discontinued 6” Pipe Length, Galvanized 46DVA-06 908 4DT-6 N/A 4D6 SV4L6 6” Pipe Length, Black 46DVA-06B 908B 4DT-6B N/A 4D6B SV4LB6 7” Pipe Leng
                    
                    Summary of the content on the page No. 11 
                    
                        INSTALLATION 4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.) Components from different Manufacturers may not be mixed.  Not All Rigid Pipe components are available directly from FPI. Simpson American Metal  ® Simpson Metal-Fab Security ® Selkirk  ® Direct Vent GS Description Products ® ® Direct Vent Pro Sure Seal Secure Vent Direct-Temp™ Amerivent Direct Discontinued 46DVA-IS - N/A from FPI N/A N/A 4DAIS12 N/A SV4RSA Attic Insulation Shield 12” Attic Insulation Shield - Cold Climates 36” N/
                    
                    Summary of the content on the page No. 12 
                    
                        INSTALLATION RIGID PIPE VENTING - VERTICAL TERMINATIONS  FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES Vertical Terminations  Vertical Terminations  with Co-linear Flex System using Rigid Piping Systems The shaded  area in the diagram  shows the allowable  vertical  The shaded areas in the two diagrams below show all allowable  terminations installed in a masonry chimney. All vertical  vent instal- combinations of straight vertical and offset to vertical runs with  o lations require the
                    
                    Summary of the content on the page No. 13 
                    
                        INSTALLATION RESIDENTIAL AND MANUFACTURED HOMES /  MOBILE HOMES INSTALLATIONS ® You will require the following components with your new Regency Rear Vent Direct Vent Freestanding Gas Stove. Please review your product to  make sure you have everything you need. In the event that you are missing any part, contact your dealer. Decorative brass or chrome trim kits are  available from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover.  Note: These are the minimum piece
                    
                    Summary of the content on the page No. 14 
                    
                        INSTALLATION  d) Slide the appliance and vent assembly  towards the wall carefully inserting the  vent pipe into the riser vent terminal  assembly. It is important that the vent  pipe extends into the Riser Vent Backing  Plate a suffi cient distance so as to result  in a minimum pipe overlap of   1-1/4 inches. Secure the connection  between the vent pipe and the vent cap  by attaching the two sheet metal strips  extending from the Riser Vent Backing  Plate into the outer wall of the vent pipe.  U
                    
                    Summary of the content on the page No. 15 
                    
                        INSTALLATION VERTICAL TERMINATION WITH  CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING  A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Ar- rangements chart in the "Rigid Pipe Venting - Vertical Terminations" section for minimum and maximum fl ue lengths.See chart  below for minimum  distances from roof. Periodically check that t
                    
                    Summary of the content on the page No. 16 
                    
                        INSTALLATION 4) Pass the fl ex pipe down through the center of  Approved for US Installations Only CONVERTING CLASS-A  the chimney system, and center the adaptor  The use of an existing chimney as an air  on the top of the chimney pipe. Drill four 1/8"  METAL CHIMNEY OR intake is not covered under the ANSI Z21.88b- diameter holes through the adaptor and into  2003/CSA 2.33b-2003 test methods and the  MASONRY CHIMNEY TO the chimney top. Insure that   you are in fact,  resulting ITS/WHI product cer
                    
                    Summary of the content on the page No. 17 
                    
                        INSTALLATION CONVERTING  MASONRY CHIMNEY Important: The existing  masonry fl ue open- ing needs to have an area of at least a 36 sq.  in. to insure proper intake/exhaust fl ow. 1) Before cutting any holes, assemble the  desired sections of black direct vent pipe  to determine the center of the masonry  penetration. Termination Cap Diagram 9 Top Adaptor Flashing 9) Slide the Wall Thimble Cover (Part # 940)  over the Retro Connector and secure with  Diagram 7 masonry bolts. Diagram 10. If you have a
                    
                    Summary of the content on the page No. 18 
                    
                        INSTALLATION CONVERSION KIT# 514-969 FROM NG TO LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 5) Unscrew the pilot orifi ce with the allen  Installation of LPG  Each Kit contains one LPG  key; then replace with the LPG pilot  Conversion Kit: Conversion Kit and one DC orifi ce and the pilot cap, provided in the  1) Shut off the gas supply. kit. Sparker Kit. 2) Open the front door and carefully re- Conversion Kit Contains: move the logs and lava r
                    
                    Summary of the content on the page No. 19 
                    
                        INSTALLATION 16) Re-assemble the black protection cap  9) Pull off the Hi/Lo gas extension knob to 12) Check that the screw is clean and if  access the orifi ce. (Fig. 6). necessary remove dirt. 13) Flip the screw (Fig. 3). Fig.6 17) Reverse steps 4 - 1. Fig.3 WARNING! Also check that the pilot and main  14) Using the Allen wrench  as shown in Fig.4, rotate  burner injectors are appropriate for  the screw clockwise until  the gas type. snug, do not overtighten. Fig.4 10) Remove the black  18)  At
                    
                    Summary of the content on the page No. 20 
                    
                        INSTALLATION GAS CONNECTION LOG SET  AERATION  ADJUSTMENT INSTALLATION o The gas connection is a 3/8" NPT 90 elbow.  The gas line can be rigid pipe or to make in- Read the instructions below carefully and  The burner aeration is factory set but may need  stallation easier, use a listed fl exible connector  adjusting due to either the local gas supply, air refer to the diagrams.  If logs are broken  and/or copper tubing if allowed by local codes.  do not use the unit until they are replaced.  supp