Summary of the content on the page No. 1 
                    
                        www.regency-fi re.com
ULTIMATE U39 
Owners & 
Direct Vent Freestanding Gas Stove
Installation Manual
MODELS: U39-NG1 Natural Gas U39-LP1 Propane
WARNING:  FOR YOUR SAFETY
If the information in these instructions are not followed exactly, What to do if you smell gas:
a fi re or explosion may result causing property damage,  Do not try to light any appliance
personal injury or loss of life.  Do not touch any electrical switch: 
do not use any phone in your 
FOR YOUR SAFETY
building.
Do not store or 
                    
                    Summary of the content on the page No. 2 
                    
                        ® REGENCY ULTIMATE Direct Vent Freestanding Gas Stove To the New Owner: Congratulations!  You are the owner of a state-of-the-art ULTIMATE Direct Vent Gas Stove by FPI Fireplace  ® Products International Ltd. The Regency Gas Series of hand crafted appliances has been designed to  provide you with all  the warmth and charm of a woodstove, at the fl ick of a switch.  The models U39-NG1,  and U39-LP1 of this series has been approved by Warnock Hersey for both safety and effi ciency. As it  also bears
                    
                    Summary of the content on the page No. 3 
                    
                        TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Copy of Safety Label .....................................................4 Operating Instructions  ................................................34 Shutdown Instructions .................................................34 First Fire ......................................................................34 REQUIREMENTS  Lighting Procedure ......................................................34 Automatic Convection Fan Operation ............
                    
                    Summary of the content on the page No. 4 
                    
                        SAFETY LABEL ® label is located on the inside of the drop NOTE: Regency units are constantly  This is a copy of the label that accompanies  being improved. Check the label on the  down pedestal door.  each ULTIMATE Direct Vent Freestanding  unit and if there is a difference, the label  Gas Stove. We have printed a copy of the  on the unit is the correct one. contents here for your review. The safety  Copy of Safety Label for U39 Gas Stove For the State of Massachusetts, installation and repair m
                    
                    Summary of the content on the page No. 5 
                    
                        REQUIREMENTS  MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements:  (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for  residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than  seven (7) feet above finished gr
                    
                    Summary of the content on the page No. 6 
                    
                        INSTALLATION This appliance installation must comply with  IMPORTANT MESSAGE AWAY FROM FURNITURE AND  the manufacturer's installation instructions and  DRAPERIES. local codes, if any. In the absence of local codes  SAVE THESE  follow the current National Fuel Gas Code, ANSI  INSTRUCTIONS Z223.1 and the current National Electrical Code  WARNING: FAILURE TO INSTALL  ANSI/NFPA 70 in the U.S.A., and the current  THIS APPLIANCE CORRECTLY  The ULTIMATE Direct Vent Freestanding Gas CAN/CGA B149 Gas Ins
                    
                    Summary of the content on the page No. 7 
                    
                        INSTALLATION 4) This appliance is Listed for bedroom  Before leaving this unit with the customer,  8) Any safety glass removed for servicing  installations when used with a Listed Millivolt the installer must ensure that the appliance is  must be replaced prior to operating the  Thermostat. Some areas may have further appliance.  fi ring correctly and operation fully explained  requirements, check local codes before to customer. installation. 9) To prevent injury, do not allow anyone who  is  unf
                    
                    Summary of the content on the page No. 8 
                    
                        INSTALLATION A) Cross Corner  VENTING   B) Room Divider C) Island   INTRODUCTION D) Flat on Wall E) Flat on Wall Corner The DV Stove Horizontal Vent Kit and the  F) Flush with Wall/ Alcove Simpson Dura-Vent Direct Vent System Model  DV-GS venting systems, in combination with the  ULTIMATE Direct Vent Freestanding Gas Stove,   U39-NG1, and U39-LP1, have been tested and  listed as direct vent heater systems by Warnock  Hersey. If converting a Class-A Metal Chimney  or Masonry Chimney to a Direct V
                    
                    Summary of the content on the page No. 9 
                    
                        INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS ® 9 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove A= Clearance above grade, veranda, porch, deck, or balcony *(min. with Dura-Vent termination cap (min. 12"/30cm) 12"/30cm) H= Not to be installed above a meter/regulator assembly within (3'/90cm)  B= Clearance to window or door that may be opened *(12"/30cm) horizontally from the centerline of the regulator. C= Clearance to permanently closed window *(min. 12"/30cm) J= Clearance to service r
                    
                    Summary of the content on the page No. 10 
                    
                        INSTALLATION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed.  Not All Rigid Pipe components are available directly from FPI. Simpson  American Metal  ® Simpson Metal-Fab Security ® Selkirk  ® Direct Vent GS Description Products ® ® Direct Vent Pro Sure Seal Secure Vent Direct-Temp™ Amerivent Direct Discontinued 6” Pipe Length, Galvanized 46DVA-06 908 4DT-6 N/A 4D6 SV4L6 6” Pipe Length, Black 46DVA-06B 908B 4DT-6B N/A 4D6B SV4LB6 7” Pipe Leng
                    
                    Summary of the content on the page No. 11 
                    
                        INSTALLATION 4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.) Components from different Manufacturers may not be mixed.  Not All Rigid Pipe components are available directly from FPI. Simpson American Metal  ® Simpson Metal-Fab Security ® Selkirk  ® Direct Vent GS Description Products ® ® Direct Vent Pro Sure Seal Secure Vent Direct-Temp™ Amerivent Direct Discontinued 46DVA-IS - N/A from FPI N/A N/A 4DAIS12 N/A SV4RSA Attic Insulation Shield 12” Attic Insulation Shield - Cold Climates 36” N/
                    
                    Summary of the content on the page No. 12 
                    
                        INSTALLATION  RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate  Horizontal Ter- mination Caps WARNING: Do not combine venting components from  different venting systems. TM However use of the the AstroCap and FPI  Riser is acceptable with all systems. This product has been evaluated by Intertek for  using a Rigid Pipe Adaptor in conjunction with  When using Rigid Vent other than Duravent Direct-Vent GS, Selkirk Direct-Temp,  Simpson Dura-Vent, 3 screws must be  Ameri Vent
                    
                    Summary of the content on the page No. 13 
                    
                        INSTALLATION INSTALLATION  RIGID PIPE VENTING ARRANGEMENTS PRECAUTIONS Horizontal Terminations for All Vertical Termination Systems for  These venting systems are engineered Venting Systems Residential Manufactured and  products that have been designed and  Mobile Homes tested for use with the U39-NG1, and The shaded areas in the diagram below show  U39-LP1. The warranty will be voided all allowable combinations of vertical runs  The shaded area in the diagram below shows all  with horizontal te
                    
                    Summary of the content on the page No. 14 
                    
                        INSTALLATION o Horizontal Venting with Two (2) 90 Elbows o o One 90 elbow = Two 45 elbows.  Option     V          H + H1      A) 3'  Min.      2' Max.      B) 5'  Min.      3' Max.      C) 8'  Min.      4' Max.       With these options, maximum total  pipe length is 30 feet with minimum  of 8 feet total vertical and maximum  4 feet total horizontal. Please note minimum 1 foot  o between 90 elbows is required. Lengths do not include elbow  indicated Vent restrictor position A (fully  open), Refer
                    
                    Summary of the content on the page No. 15 
                    
                        INSTALLATION DV STOVE HORIZONTAL VENT KIT (# 946-116 & #946-216) DV Stove Horizontal Vent Kit (2 ft. Part # 946-116 or 4 ft. Part # 946-216) includes all the parts needed to install the U39 with  minimum horizontal  and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents  see the "Dura-vent Termiantion Kit and Component" sections.      Qty. Description 1) 1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,   Kit # 946-216: 4 ft. (1.2m) length), 
                    
                    Summary of the content on the page No. 16 
                    
                        INSTALLATION   Note: if the centerline cannot be met,  the adjustable sections will have to  be cut.  e) Cut the 2 ft. or 4 ft. section of rigid pipe  to length. Ensure that the pipe length  when cut will seat onto both the starter  o collar and the 90 elbow.  Crimped  section of rigid pipe seats into the  o 90 elbow. Only cut the uncrimped  side of pipe.   Dismantle all pipe sections including vent  terminal. 3) Attach the 4" dia. fl ex liner to the vent  terminal ensuring that the fl ex overlaps
                    
                    Summary of the content on the page No. 17 
                    
                        INSTALLATION DURA-VENT DURA-VENT VENTING  TERMINATION KIT COMPONENTS You will require the following components with Minimum components for a Dura-Vent  Planning Your Dura-Vent  ® your new Regency Direct Vent Freestanding Horizontal Installation: Installation Gas Stove. Please review your product to make   sure you have everything you need. In the A) Dura-Vent Horizontal Termination Kit There are two basic types of Dura-Vent Direct  B) Wall Thimble (required  for combus- event that you are missin
                    
                    Summary of the content on the page No. 18 
                    
                        INSTALLATION  Note: Note: DURA-VENT  a) Twist-lock procedure: Four  indentations,   a) The horizontal run of vent should have  located on the female ends of pipes and a 1/4 inch rise for every 1 foot of run  HORIZONTAL  fi ttings, are designed to slide straight  towards the termination. Never allow the  TERMINATIONS onto the male ends of adjacent pipes  vent to run downward. This could cause  and fi ttings, by orienting the four pipe  high temperatures and may present the  indentations so they mat
                    
                    Summary of the content on the page No. 19 
                    
                        INSTALLATION Note: If installing termination on a siding   Below Grade Installation DURA-VENT VERTICAL   covered wall, a vinyl siding standoff   If the Snorkel Termination must be installed   or furring strips must be used to   TERMINATIONS below grade, i.e. basement application, proper   ensure that the termination is not   drainage must be provided to prevent water from   recessed into the siding. The four   entering the Snorkel Termination. Refer to Dia. 1) Maintain the 1-1/4"   wood screws p
                    
                    Summary of the content on the page No. 20 
                    
                        INSTALLATION 4) Assemble the desired lengths of black pipe  Offset Chart     Roof Pitch                   Minimum Vent Height and  elbows necessary to reach from the                                             Feet         Meters appliance adaptor up though the Round  fl at to 7/12 2     0.61 Support Box. Insure that all pipes and elbow  connections are in the fully twist-locked over 7/12 to 8/12 2 0.61 position and sealed. over 8/12 to 9/12 2 0.61 over 9/12 to 10/12 2.5 0.76 5) Cut a hole in the