Summary of the content on the page No. 1 
                    
                         
 
OIL FIRED FURNACE 
INSTALLATION AND OPERATION MANUAL  
WITH USERS INFORMATION SECTION 
 
MODELS: 
 
OC2-56    OL2-56   OH2-56 
OC5-85    OL5-85   OH3-72 
      OL11-105   OH5-85 
OT5-85    OL16-125   OH11-105 
OT11-105    OL20-151   OH16-125 
OT16-125    OL33-200 
      OL37-250 
      OL39-320 
 
 WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE 
OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. 
DO NOT STORE OR USE GASOL
                    
                    Summary of the content on the page No. 2 
                    
                          I.  SAFETY SECTION    This page contains various warnings and cautions found throughout the Oil Furnace  Manual. Please read and comply with the statements below.      WARNING AND CAUTIONS:    WARNING: This furnace is not to be used as a construction heater. See Page 1.      CAUTION MUST BE TAKEN NOT TO EXCEED 90° ROTATION (OF THE FLUE  ELBOW) COUNTERCLOCKWISE FROM THE VERTICAL POSITION. See Page 2.    WARNING: When cutting openings in the casing DO NOT CUT ANY SUPPORTING  CLIP
                    
                    Summary of the content on the page No. 3 
                    
                        All installations and services must be performed by qualified service personnel.    This page contains reproductions of the various instruction and warning labels placed on  the Thermo Pride Oil Furnaces. Please read and comply with the contents of these labels.     ii                                                                                                                                                                                                                                       
                    
                    Summary of the content on the page No. 4 
                    
                        All installations and services must be performed by qualified service personnel.                                                             TABLE OF CONTENTS  SECTION                                               BEGINNING PAGE    I.   SAFETY SECTION        i   II.   GENERAL INSTRUCTIONS        1                          A. DRAFT REGULATORS       3  B. DUCT WORK/AIR CONDITIONING     3  C. FILTERS MOUNTED EXTERNAL TO FURNACE   4  D. FAN AND LIMIT POSITION  AND LOCATION    6  E. BURNER INSTALLATI
                    
                    Summary of the content on the page No. 5 
                    
                        All installations and services must be performed by qualified service personnel.    II.  GENERAL INSTRUCTIONS - READ BEFORE START OF INSTALLATION    1. The heating output capacity of the furnace proposed for installation should be based on a heat loss calculation  made according to the manuals provided by the Air Conditioning Contractors of America (ACCA) or the American  Society of Heating, Refrigeration and Air Conditioning Engineers, Inc. (ASHRAE).    2. All local codes and/or regulations tak
                    
                    Summary of the content on the page No. 6 
                    
                        All installations and services must be performed by qualified service personnel.    The minimum clearances listed in the preceding table are for fire protection.  Clearance for servicing the front of the  furnace and the rear of the lowboy models should be at least 24 inches.  A clearance of 24 inches is recommended  for passage to all points on the furnace requiring service access.      The OH2-3-5-11-16 furnaces may be installed on combustible flooring.  The OL2-5-11-16-20-33-37-39 and OC2-5  
                    
                    Summary of the content on the page No. 7 
                    
                        All installations and services must be performed by qualified service personnel.    NOTE:  ROTATION OF FLUE PIPE IS ONLY ALLOWED FOR LEFT HAND SIDE VENTING  APPLICATIONS.    TABLE 1: Suggested sizes and positions of flue pipe opening on left hand side of casing.              TRIM COLLAR/  UNIT  DIA. HOLE “X” DIM. “Y” DIM. FLUE DIA. GASKET PART #    OC2  5-1/2”  3-5/8”  28-3/8”  5”  14121/330073  OC5  6-1/2”  4-3/4”  31-7/16”  6”  14131/330005  OH2  5-1/2”  3/5/8”  28-3/8”  5”  14121/330073  OH3 
                    
                    Summary of the content on the page No. 8 
                    
                        All installations and services must be performed by qualified service personnel.    The duct system should again follow the current design standard of Air Conditioning Contractors of America                  (ACCA) or ASHRAE Fundamentals volume.    The most common location for the A-shaped coil (A style) is shown in Fig. 2.    Fig 2: Acceptable locations for the air conditioner evaporator coil.    NOTICE: The minimum coil  pan clearance for a sectional or drum type heat exchanger is three inches
                    
                    Summary of the content on the page No. 9 
                    
                        All installations and services must be performed by qualified service personnel.    On highboy furnaces, it is necessary to cut the return air opening in the side or rear casing, depending upon the  needs of the specific installation.    The filter rack provided with the furnace, refer to Fig. 5, will serve as a template to scribe a mark for the return air  opening on the casing. Place the filter rack on the casing one inch up from the bottom of the furnace and centered  from side to side. Place
                    
                    Summary of the content on the page No. 10 
                    
                        All installations and services must be performed by qualified service personnel.    D.  FAN AND LIMIT POSITION AND LOCATION    WARNING:  The predetermined fan and limit locations on all of the Thermo Pride oil fired  furnaces have been tested and approved by Thermo Products, LLC. in conjunction with  Underwriters Laboratories, Inc. Any attempt to relocate these safety controls or replace these  safety controls with a control that is not approved, or is incompatible, may result in personal  i
                    
                    Summary of the content on the page No. 11 
                    
                        All installations and services must be performed by qualified service personnel.    The oil burner will mount on three stud mounting bolts on the lower mounting plate covering the opening in the front  of the heat exchanger. The end of the burner tube should be inserted no further than 1/4 inch back from the inside  surface of the combustion chamber. A distance further than 1/4 inch back from the inside chamber wall may cause  impingement and sooting.    NOTE: OVERFIRE AIR TAP MAY BE LOCATED ON 
                    
                    Summary of the content on the page No. 12 
                    
                        All installations and services must be performed by qualified service personnel.      Fig. 10: (Side view) Burner insertion illustration    F.  HORIZONTAL FURNACE POSITIONS:    The horizontal furnace may be turned end for end, or rotated, making the top into the bottom, as shown in Fig. 11.    Fig. 11: A horizontal furnace rotated 180° (or flipped end for end) to reverse airflow direction    After the furnace has been positioned, the bottom burner mounting stud must be broken off before mounting
                    
                    Summary of the content on the page No. 13 
                    
                        All installations and services must be performed by qualified service personnel.    The OL33, 37 and 39 furnaces have an external wire harness that mounts in pre-punched holes in the side casings  (See Fig. 13).    A Horizontal furnace is shown below with external wire harness and fan speed terminal strip (blower access panel  removed). (See Fig. 14).    Fig. 14: The wiring system of a typical horizontal furnace    H. BURNER SPECIFICATIONS AND APPLICATIONS  THERMO PRIDE BURNER APPLICATIONS  FURN
                    
                    Summary of the content on the page No. 14 
                    
                        All installations and services must be performed by qualified service personnel.    STANDARD BURNER NOZZLES: The OL2, OH2, OC2 and OC1, along with the OL33, OL37 and OL39 have  the nozzles already installed in the burners. The balance of the oil units has the nozzles shipped as loose items with  the furnace. Below is a chart showing the heating capacity of the furnace for each approved nozzle size.      OIL NOZZLE CAPACITY CHART        EQUIVALENT  EFFECTIVE        HEAT   HEATING        INPUT RAT
                    
                    Summary of the content on the page No. 15 
                    
                        All installations and services must be performed by qualified service personnel.    RIELLO BURNER APPLICATION CHART    The optional F3 and F5 Riello flame retention oil burners have been UL listed (UL File #MP3252) for application on  the following Thermo Pride oil fired furnaces.                 MODEL OC5, OL5, OL11, OH11,  OL16, OH16,  OH3 OL20  PART OH5, OT5 OT11 OT16  MTG. PLATE  TOP-25752 35750  35750 35750 35750  PART NO.  BTM-35733   MTG. PLATE  GASKET  330090 330088 330088 330088 330088 
                    
                    Summary of the content on the page No. 16 
                    
                        All installations and services must be performed by qualified service personnel.                                                        Fig. 15: Typical Heat Exchanger Cleanout Cover Locations.    With access to the inside of the heat exchanger through the burner area, clean-out openings, and vent pipe  connection, it is possible to use a long, flexible wire brush and an industrial type vacuum cleaner to remove any soot  build-up. NOTE: A one inch (outside diameter) vacuum cleaner hose will fit 
                    
                    Summary of the content on the page No. 17 
                    
                        All installations and services must be performed by qualified service personnel.    C. INSPECTION AREAS    VESTIBULE:  The furnace vestibule area or burner compartment should be inspected by removing the front door of  the furnace and looking for signs of excessive heat such as discoloration of components materials damage, from rust  or corrosion, soot or carbon build-up.  EXTERIOR OF FURNACE:  The furnace exterior should be inspected for signs of excessive heat such as  discoloration of materia
                    
                    Summary of the content on the page No. 18 
                    
                        All installations and services must be performed by qualified service personnel.        Fig. 17: Location of the air filter and blower compartment access door on the typical lowboy furnace.    OH Series (Highboy)     The filter rack will be located between the return air plenum and the return air opening on the side of the  furnace, refer to figure 18. Slide the dirty filter out, clean it with a mild soap and water solution. Make sure filter is  thoroughly dry before replacing.    Fig. 18: Locat
                    
                    Summary of the content on the page No. 19 
                    
                        All installations and services must be performed by qualified service personnel.    COMBUSTION AND EFFICIENCY TESTING FOR THERMO PRIDE OIL FIRED CENTRAL FURNACES. Complete this form for each Thermo Pride furnace installed. Read instruction manual carefully before making tests. Retain this form with furnace. CUSTOMER NAME ADDRESS CITY, STATE BURNER MODEL NO. BLAST TUBE LGTH. AIR SHUTTER OPENING HEATING INS. % OF MAX. (EST) SYSTEM CONDITION MATERIAL FURNACE MODEL COMBUSTION CHAMBER TYPE OF VENTING
                    
                    Summary of the content on the page No. 20 
                    
                        All installations and services must be performed by qualified service personnel.    APPENDIX-A Replacement Parts List  16