TWO STAGE CONDENSING GAS FURNACE  
 
INSTALLATION AND OPERATION MANUAL 
 
 
MODELS: 
 
FOR USE WITH NATURAL GAS  OR LP GAS (PROPANE) 
CHX1-75N  CDX1-75N 
CHX1-100N  CDX1-100N 
CHX1-125N  CDX1-125N 
 
 
 
: IF YOU DO NOT FOLLOW THE SAFETY PRECAUTIONS BELOW AND IN THIS 
MANUAL, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL 
INJURY, OR LOSS OF LIFE. 
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE 
VICINITY OF THIS OR ANY OTHER APPLIANCE. 
 
WHAT TO 
                    
                    Summary of the content on the page No. 2 
                    
                        All installations and services must be performed by qualified service personnel.    I. SAFETY INFORMATION  This and the following page contain reproductions of the various warning and instruction labels placed on  the Thermo Pride Two Stage Condensing Gas Furnaces.  Please read and comply with the contents of  these labels.        i                                                                                                                                                                      
                    
                    Summary of the content on the page No. 3 
                    
                        All installations and services must be performed by qualified service personnel.    This and the previous page contain reproductions of the various warning and instruction labels placed on  the Thermo Pride Two Stage Condensing Gas Furnaces.  Please read and comply with the contents of  these labels.  The following safety information should be read, understood, and followed by the installer.    ii                                                                                                    
                    
                    Summary of the content on the page No. 4 
                    
                        All installations and services must be performed by qualified service personnel.    1. Use only with type of gas approved for this furnace.  Refer to furnace rating plate.    2. Connect this furnace to an approved vent system only.  Combustion products must be carried outdoors.   Refer to Section III, D thru H, of this manual.     The following pages contain various warnings and cautions found throughout the Thermo Pride  Highboy and Dual Poise Two Stage Condensing Gas Furnace Manual. Please rea
                    
                    Summary of the content on the page No. 5 
                    
                        All installations and services must be performed by qualified service personnel.    : Personal injury or property damage could result from repair or service of this furnace  by anyone other than a qualified heating contractor. Only the homeowner/user routine  maintenance described in the Users Information Manual may be performed by the user.                                                                                         iv                                                                  
                    
                    Summary of the content on the page No. 6 
                    
                        All installations and services must be performed by qualified service personnel.    INDEX    SECTION         BEGINNING PAGE    I. SAFETY INFORMATION       i  II. FURNACE SPECIFICATIONS       1  III. GENERAL INSTALLATION       6   A.  CODES AND CLEARANCES      6   B.  FURNACE LOCATION       7   B1.CDX1 HORIZONTAL APPLICATION      7   C.  REPLACING EXISTING FURNACE FROM A COMMON VENT  9   D.  GENERAL REQUIREMENTS FOR VENTING CHX1/CDX1   9   E.  SIDEWALL VENTING       10   E1.  SINGLE PIPE (SIDEWAL
                    
                    Summary of the content on the page No. 7 
                    
                        All installations and services must be performed by qualified service personnel.      II.  FURNACE SPECIFICATIONS    CHX1 SERIES    MODEL NO. CHX1-75 CHX1-100 CHX1-125  BTU/HR INPUT (High fire/ Low fire) 75,000 / 52,000 100,000 / 70,000 125,000 / 87,500 BTU/HR OUTPUT (High fire/ Low fire) 70,875 / 49,612 94,500 / 66,150 117,500 / 82,250      HEIGHT OF CASING 44-1/4” 44-1/4” 44-1/4”  17” 21” 24”  WIDTH OF CASING  DEPTH OF CASING 27-1/2” 27-1/2” 27-1/2”  WARM AIR OUTLET 15 x 18 19 x 18 22 x 18  25
                    
                    Summary of the content on the page No. 8 
                    
                        All installations and services must be performed by qualified service personnel.        CDX1 SERIES    MODEL NO. CDX1-75 CDX1-100 CDX1-125  BTU/HR INPUT (High fire / Low fire) 75,000 / 56,250 100,000 / 75,000 125,000 / 93,750 69,750 / 52,312 93,000 / 69,750 116,250 / 87,187 BTU/HR OUTPUT (High fire / Low fire)       HEIGHT OF CASING 46-1/4” 46-1/4” 46-1/4”  17” 21” 24”  WIDTH OF CASING  DEPTH OF CASING 27-1/2” 27-1/2” 27-1/2”  WARM AIR OUTLET 15 x 18 19 x 18 22 x 18  15 x 22 19 x 22 22 x 22  RET
                    
                    Summary of the content on the page No. 9 
                    
                        All installations and services must be performed by qualified service personnel.        INSTALLATION PARTS PACKAGES – CHX1-75    PARTS PACKAGE  DESCRIPTION PART # QUANTITY  #S00S4378   2-3/8” ID radiator hose 410017 1  Thermostat lead bushing 350750 1     PVC trap assembly 320816 1   #8 x ¾ coated TEK screws for   300283 4  mounting trap & inlet/outlet collars  11/16” OD x 1/2” ID vinyl tubing 410060 24”     2 x 4 electrical J-box 350024 1   2 x 4 electrical J-box cover 350020 1  #8 x ½ TEK scre
                    
                    Summary of the content on the page No. 10 
                    
                        All installations and services must be performed by qualified service personnel.        INSTALLATION PARTS PACKAGES – CDX1-75    PARTS PACKAGE  DESCRIPTION PART # QUANTITY  #S00S4380   2-3/8” ID radiator hose 410017 1  Thermostat lead bushing 350750 1     PVC trap assembly 320816 1   #8 x ¾ coated TEK screws for   300283 6  mounting trap & inlet/outlet collars  11/16” OD x ½” ID vinyl tubing 410060 24”     2 x 4 electrical J-box 350024 1   2 x 4 electrical J-box cover 350020 1  #8 x ½ TEK screws
                    
                    Summary of the content on the page No. 11 
                    
                        All installations and services must be performed by qualified service personnel.        INSTALLATION PARTS PACKAGES – CDX1-100-125    PARTS PACKAGE  DESCRIPTION PART # QUANTITY  #S00S4381   2-3/8” ID radiator hose 410017 1  Thermostat lead bushing 350750 1     PVC trap assembly 320816 1   #8 x ¾ coated TEK screws for   300283 4  mounting trap & inlet/outlet collars  11/16” OD x 1/2” ID vinyl tubing 410060 24”     2 x 4 electrical J-box 350024 1   2 x 4 electrical J-box cover 350020 1  #8 x ½ TEK
                    
                    Summary of the content on the page No. 12 
                    
                        All installations and services must be performed by qualified service personnel.    III. GENERAL INSTALLATION    These Category Type IV furnaces are shipped completely assembled and wired (internally). See the  Dealer Receiving and Freight Claim Procedure Section of the price guide for parts shortage or damage.  The furnace and duct system must be adjusted to obtain a temperature rise of 55°F to 85°F through the  furnace after installation. (See rating label located on side panel inside the furn
                    
                    Summary of the content on the page No. 13 
                    
                        All installations and services must be performed by qualified service personnel.    Equipment must be installed in accordance with regulations of the National Board of Fire  Underwriters. Authorities having jurisdiction should be consulted before installations are made.      B. FURNACE LOCATION    : These high efficiency condensing furnaces are not certified for and shall not be  vented into a standard or any type of chimney.    The following shall be considered for locating the furnace:    1. F
                    
                    Summary of the content on the page No. 14 
                    
                        All installations and services must be performed by qualified service personnel.    NOTE: When the CDX1 is installed as horizontal unit, it is imperative that the auxiliary limit switch and  bracket be located on the upper side of the house air blower; the burner rollout switch located on the  burner box be relocated to the side of the burner box; and that the hose from the single tap pressure  switch be connected to the lower tap on the front of the collector box (See Figure 1).       Figure 1 
                    
                    Summary of the content on the page No. 15 
                    
                        All installations and services must be performed by qualified service personnel.    Equipment must be installed in accordance with regulations of the National Board of Fire  Underwriters and the National Fuel Gas Code. Authorities having jurisdiction should be consulted  before installations are made.      C.  REPLACING AN EXISTING FURNACE FROM A COMMON VENT    : These furnaces may not be common vented with any other appliance.      D.  GENERAL REQUIREMENTS FOR VENTING CHX1/CDX1    The CHX1/CDX1
                    
                    Summary of the content on the page No. 16 
                    
                        All installations and services must be performed by qualified service personnel.    NOTES:  1  The drain tee supplied with CHX1/CDX1 furnaces count as 1 elbow.  2   (2) 45° elbows can be substituted for (1) 90° elbow.    Care should be taken to plan out the vent system to be as short as possible (but not shorter than 8 ft.) and  to contain as few elbows as possible to insure the best possible operation of the furnace.    8. A hack saw may be used to cut the PVC pipe. It must be cut smoothly at r
                    
                    Summary of the content on the page No. 17 
                    
                        All installations and services must be performed by qualified service personnel.    NOTICE:  If exterior sidewall building materials are subject to degradation from flue gases or moisture, a  minimum 12” diameter shield made from stainless steel or high density plastic shall be used for protection.    2.  The PVC vent termination elbow must be installed in accord with local codes and these instructions.  The bottom edge of the vent termination elbow must be installed at least 12 in. above the ou
                    
                    Summary of the content on the page No. 18 
                    
                        All installations and services must be performed by qualified service personnel.    Figure 4  : The vent and air intake elbows must be kept away from bushes, shrubs or any  vegetation that may restrict the flow of flue products. It must also be kept clear of any leaves,  weeds or other combustible materials. Keep the vent hood clear of snow. Avoid locating the  terminals in areas where standing water or condensate drippage may be a problem.    VENT TERMINAL LOCATION GUIDELINES  In addition to fo
                    
                    Summary of the content on the page No. 19 
                    
                        All installations and services must be performed by qualified service personnel.    F.  INSTALLATION OF OUTSIDE VENT/AIR INTAKE TERMINATIONS    NOTICE:  Installation of the outside exhaust and combustion air vents must be performed by a qualified  installer or service person in accord with local codes, the National Fuel Gas Code (NFPA 54, ANSI Z223.1  or latest edition) and the sections on venting in this manual.    1. Observing all clearances specified in this manual, cut two 2-3/8” diameter ho
                    
                    Summary of the content on the page No. 20 
                    
                        All installations and services must be performed by qualified service personnel.        G.  CONNECTING FURNACE TO THE VENT/AIR INTAKE TERMINATION AND         DRAIN    1.  The following diagrams show the typical vent and air inlet connection for a CHX1 and CDX1 furnace  as well as a list of the parts that will be needed to install each.    Figure 6  14