Summary of the content on the page No. 1 
                    
                        F14 and 48000 SERIES
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all 
components immediately. See page 3.
Hot Food Tables
Effective May 2003
IMPORTANT INFORMATION
READ BEFORE USE
C A U T I O N
PLEASE SAVE THESE INSTRUCTIONS!                                                                                                                                                                   
                    
                    Summary of the content on the page No. 2 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual CONTENTS SERIAL NUMBER LOCATION The serial number on all 14 Series and 48000 Series hot  SERIAL# LOCATION..............................................................2 food tables is printed on the tag located on the plate shelf. RECEIVING & INSPECTING ..................................................2 Always have the serial number of your unit available when  SPECIFICATIONS ..............
                    
                    Summary of the content on the page No. 3 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual SPECIFICATIONS MODEL          NUMBER OF        NUMBER OF                                             SHIP MODEL                   NUMBER OF                     AMPS                                 SHIP NUMBER       OPENINGS*      GAS BURNERS             BTU                    WEIGHT NUMBER                 OPENINGS                     208/230                            WEIGHT Gas with single 
                    
                    Summary of the content on the page No. 4 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual OPERATION: F14EI & 48300 SERIES (ELECTRIC) Before the unit is used the first time for serving, turn the  Wet operation temperature knob to “10” and heat the well for 20 to 30 minutes.                     1)  Fill food well with two inches of water. For quicker  Do not be alarmed if smoke appears; this preheat should burn off  pre-heating, use hot water to fill the well.  any residue or dust 
                    
                    Summary of the content on the page No. 5 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual OPERATION: F14GW SERIES (GAS) Lighting the pilot Gas connection Only qualified and trained personnel  Only qualified and trained personnel should attempt  should attempt to light the pilot. Wear  to connect the gas. Wear a face shield during this  a face shield during this procedure.  procedure. Delfield is not responsible for injuries  Delfield is not responsible for injuries  resulting fro
                    
                    Summary of the content on the page No. 6 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual GAS BURNER ASSEMBLY: F14GW SERIES (SINGLE SHOWN) NOTE: The same parts are used for the  double burner assembly 7 2 4 8 6 5 2 2 9 1 10 3 16 15 15 16 15 16 2 20 13 17 12 11 1 18 15 21 16 14 23 23 19 22 KEY   QTY       PART#               DESCRIPTION KEY   QTY      PART#               DESCRIPTION 1            2         3547413                 elbow 1/2” NPT 13          1         3234023      de
                    
                    Summary of the content on the page No. 7 
                    
                        5.56 5.50 8.50 2.31 CLEAR F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual DELFIELD FOOD WELL (DFW) ASSEMBLY: WITH THERMOSTATIC CONTROL 11 2 4 THERMOSTATIC CONTROL 7   KEY          PART NAME                                DELFIELD PART # Complete assembly, 115V,  thermostat w/drain      XMK00100 Complete assembly, 115V,  thermostat w/o drain   XMK00101 Complete assembly, 208V,  thermostat w/drain      XMK00102 Complete assembly, 208V,  the
                    
                    Summary of the content on the page No. 8 
                    
                        8.50 2.31 CLEAR F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual DELFIELD FOOD WELL (DFW) ASSEMBLY: WITH INFINITE CONTROL 10 2 4 INFINITE CONTROL 7   KEY          PART NAME                                DELFIELD PART # Complete assembly, 115V, infinite w/drain              XMK00104 Complete assembly, 115V,  infinite w/o drain         XMK00105 Complete assembly, 208V,  infinite w/drain             XMK00068 Complete assembly, 208V,  infinit
                    
                    Summary of the content on the page No. 9 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual MISCELLANEOUS PARTS LISTS F14EI Series (electric) 48300 Series (electric) PART NAME                                                  DELFIELD PART # PART NAME                                                  DELFIELD PART # Faucet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-4075 Bullet feet (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-
                    
                    Summary of the content on the page No. 10 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual WIRING DIAGRAMS: F14EI AND 48300 SERIES pilot light (furnished) 1000 W - 120V H1  or 1000/1222 W -  P 208/230 V  L1 heating element L2 H2 line wires infinite control with “OFF” position to additional 120 or 208-240V food warmers SINGLE PHASE MODELS L1 G L2 (NEUTRAL ON 120V MODELS) "INFINITE" CONTROL HEATER 1 PILOT LIGHT 208-240V 3 PHASE MODELS HEATER 2 L1 G L2 L3 PILOT LIGHT HEATER 3 "INFINI
                    
                    Summary of the content on the page No. 11 
                    
                        RED RED BLACK L3-BLUE L2-BLACK BLACK L1-RED WHITE F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual WIRING DIAGRAMS: F14EW SERIES 120-208 OR 120-240 VOLT SINGLE PHASE SUPPLY Single Phase WHITE-NEUTRAL L2-BLACK L1-RED GREEN-GROUND TO CASE SWITCH BLACK C2 WATER LEVEL POWER RELAY CONTROL BOARD 120VAC COIL HEAT FILL H TEMPERATURE  XL   HI   C N CONTROL PILOT LIGHT BLUE 219-4095 FLOAT THERMAL  LOW WATER LIGHT WATER FILL OVERLOAD  IMMERSION  SOLE
                    
                    Summary of the content on the page No. 12 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours
                    
                    Summary of the content on the page No. 13 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual STANDARD ONE YEAR WARRANTY (One year parts, 90 days labor.) The Delfield Company (“Delfield”) warrants to the Original Purchaser being issued after the part has been received and inspected at Delfield’s  of the Delfield product (herein called the “Unit”)  that such Unit, and all plant and determined by Delfield to be within this warranty. parts thereof, will be free from defects in material 
                    
                    Summary of the content on the page No. 14 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual ADDITIONAL FOUR YEAR PROTECTION PLAN  (for Motor-Compressor only)   Installation Delfield Model# Serial # Date General Conditions Delfield shall not be liable in any manner for any default or delay  in performance hereunder caused by or resulting from any  contingency beyond Delfield’s control, including, but not limited  In addition to the Standard One Year Warranty on the Motor- to, war, g
                    
                    Summary of the content on the page No. 15 
                    
                        F14 AND 48000 Series Service and Installation Manual F14 AND 48000 Series Service and Installation Manual NOTES: 15 14 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com                                                                                                                                                                                              
                    
                    Summary of the content on the page No. 16 
                    
                        AUTHORIZED PARTS DEPOTS NOR TH AMERICA 1 2 8 5 1 3 1 1 2 1 0 6 1 4 4 1 3 7 9 4 1 2 1) The Delfield Company 3) Appliance Installation Service 2) A.I.S. Commercial Parts & Service 4) Pacific Coast Parts 980 South Isabella Road 1816 West 26th Street 1336 Main Street 15024 Staff Court Mt. Pleasant, MI 48858 Buffalo, NY 14209 Erie, PA 16508-1149 Gardena, CA 90248 800.733.8829 800.722.1252 1.800.531.1111 800.332.3732 989.773.7981 814.456.3732 716.884.7425 1.800.782.5747 989.773.3210 FAX 814.452.4843 F