Summary of the content on the page No. 1 
                    
                        ®
Intel RAID Expander Card 
RES2SV240 Hardware User’s Guide
Intel Order Number: E93121-002                                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    Summary of the content on the page No. 2 
                    
                        DISCLAIMER INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL(R)  PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY  INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS  PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL  ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED  WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY  OR WARRANTIES RELATING TO FITNESS FOR A PARTI
                    
                    Summary of the content on the page No. 3 
                    
                        Preface ® This is the primary hardware guide for the Intel RAID Expander Card RES2SV240,  which can be used to manage SAS and SATA disk drives. It contains installation  instructions and specifications. For details on configuring the storage adapters, and for an overview of the software  ® drivers, see the Intel RAID Software User’s Guide on the Resource CD. Audience This document assumes that you have some familiarity with RAID  controllers/modules/expanders and related support devices. The peo
                    
                    Summary of the content on the page No. 4 
                    
                        iv Intel® RAID Expander Card RES2SV240 Hardware User’s Guide                                                                                                                                                                                                                                                                                                                                                                                                                                                        
                    
                    Summary of the content on the page No. 5 
                    
                        Table of Contents Preface ........................................................................................................................iii Audience ............................................................................................................................... iii Organization ......................................................................................................................... iii Related Publication ..................................................
                    
                    Summary of the content on the page No. 6 
                    
                        vi Intel® RAID Expander Card RES2SV240 Hardware User’s Guide                                                                                                                                                                                                                                                                                                                                                                                                                                                        
                    
                    Summary of the content on the page No. 7 
                    
                          List of Figures Figure 1. Changing the bracket................................................................................................. 6 ® Figure 2. Installing Intel RAID Expander Card RES2SV240 ................................................... 7 Figure 3. Installing the Expander Card onto a Customized Chassis Wall................................. 8 Figure 4. Cabling among the Expander Card, RAID Module/Controller and Drives/Backplane 9 Figure 5. Card Layout.........................
                    
                    Summary of the content on the page No. 8 
                    
                          viii Intel® RAID Expander Card RES2SV240 Hardware User’s Guide                                                                                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    Summary of the content on the page No. 9 
                    
                          List of Tables Table 1. Jumper Description ...................................................................................................12 Table 2. SFF8087 to SFF8087 Connector Pin-out.................................................................. 16 Table 3. SATA Connector to SFF8087 Connector Pin-out ......................................................18 Table 4. SFF8087 (with SGPIO) Connector Pin-out ............................................................... 20 Table 5. Tech
                    
                    Summary of the content on the page No. 10 
                    
                          x Intel® RAID Expander Card RES2SV240 Hardware User’s Guide                                                                                                                                                                                                                                                                                                                                                                                                                                                       
                    
                    Summary of the content on the page No. 11 
                    
                        1 Overview ® The Intel RAID Expander Card RES2SV240 offers high performance, high disk drive  connectivity,scalability, and flexibility in various storage environments, and is an  attractive alternative to other expensive and complex topologies. The SAS expander is  ideal for high availability and scalable server clustering environments and front-end  storage subsystems used in clusters, Storage Area Networks (SANs), and Network- Attached Storage (NAS) environments. It is an optimal device for u
                    
                    Summary of the content on the page No. 12 
                    
                        ® Intel RAID Expander Card RES2SV240 ® The SAS/SATA functionality for the Intel RAID Expander Card RES2SV240 is  contained within the LSI* LSISAS2x24 24-Port Serial Attached SCSI/SATA Expander  chip. This expander card has twenty-four independent ports supporting 6Gb/s, 3 Gb/s, or  1.5Gb/s SAS and SATA data transfers using six SFF-8087 mini-SAS connectors. This  controller supports 4 inputs and 20 outputs configuration, or 8 inputs and 16 outputs  configuration. This expander card is powered eit
                    
                    Summary of the content on the page No. 13 
                    
                        • SFF-8485 protocol, using the Serial GPIO (SGPIO) interface provided by the  expander. Operating System Support The operating systems supported are determined by your RAID controller or module. See  the Tested operating system list for your RAID controller or module at  http://support.intel.com/support/motherboards/server/.  Features • Supports both Serial Attached SCSI and Serial ATA devices • 6.0 Gbit/s, 3.0 Gbit/s, and 1.5 Gbit/s data transfer rate • Six SFF-8087 mini-SAS connectors providin
                    
                    Summary of the content on the page No. 14 
                    
                        4 Intel® RAID Expander Card RES2SV240 Hardware User’s Guide                                                                                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    Summary of the content on the page No. 15 
                    
                        ® 2 Intel RAID Expander Card  RES2SV240 Hardware Installation Requirements ® • Intel RAID Expander Card RES2SV240, with full height or low profile brackets,  or with screws • Available PCI Express* x4 connector, or with available RA 4-pin power connector • SAS and SATA hard drives up to 6Gb/s speed • Six provided SAS/SATA cables (for cable requirements, see step 6 in “Installing the  RAID Module”) Note: Intel Corporation strongly recommends using an uninterruptible power supply (UPS).  Installin
                    
                    Summary of the content on the page No. 16 
                    
                        Full-height Bracket Low-profile Bracket AF003490 Figure 1. Changing the bracket 4. Install the expander card into an available server system x4, x8 or x16 PCI- Express* slot (see Figure 2). To locate an appropriate slot and for instructions on  installing an add-in card, see your server system documentation. 6 Intel® RAID Expander Card RES2SV240 Hardware User’s Guide                                                                                                                                   
                    
                    Summary of the content on the page No. 17 
                    
                        PCI Express* Slot AF003491 ® Figure 2. Installing Intel RAID Expander Card RES2SV240 5. (Optional) In case power can be supplied remotely from RA 4-pin 12V/5V power  connector, the expander card can be located elsewhere within the server chassis  instead of using a PCI Express slot, if only the cooling condition can meet the  expander card's thermal and atmospheric requirement. The expander card can  therefore be fastened by removing its bracket and fasten it to a customized chassis  wall (see F
                    
                    Summary of the content on the page No. 18 
                    
                        AF003495 Figure 3. Installing the Expander Card onto a Customized Chassis Wall 6. Connect the SAS/SATA cables from the backplane (or hard drives) to the expander  card, and from the expander card to a RAID module or RAID controller (see  Figure 4, which takes 6-drive and 4-drive non-expander backplanes in Intel's  pedestal chassis as an example for cabling). For information regarding connecting  the recommended Right-angle end or Vertical end of the SAS/SATA cable to the  SAS connectors of the c
                    
                    Summary of the content on the page No. 19 
                    
                        Figure 4. Cabling among the Expander Card, RAID Module/Controller and  Drives/Backplane 7. Install the server system cover and connect the power cords. See your server system  documentation for instructions. Configuring the Expander Card ® After physically installed into a server system, the Intel RAID Expander Card  RES2SV240 is transparent to users in RAID configurations. Refer to the technical  specification or user guide of the RAID controller connected to this expander card to  know how to 
                    
                    Summary of the content on the page No. 20 
                    
                        10 Intel® RAID Expander Card RES2SV240 Hardware User’s Guide