Desa PF-4305 user manual

User manual for the device Desa PF-4305

Device: Desa PF-4305
Category: Car Video System
Manufacturer: Desa
Size: 1.93 MB
Added : 3/14/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa PF-4305. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa PF-4305.

For your convenience

If looking through the Desa PF-4305 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa PF-4305 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa PF-4305 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa PF-4305 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa PF-4305 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa PF-4305. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATION
Mode: On-Time Works: Day Night
Test 5 Sec x x
Auto 1, 5, or 10 min x
Manual Until Dawn* x
Motion Sensing
* resets to Auto Mode at dawn.
1
Note: When first turned on wait about 1 / minutes
2
Porch Light
for the circuitry to calibrate.
TEST
Set the ON-TIME switch ON-TIME
on the sensor to TEST.
TEST 1 5 10 MIN
AUTO
PF-4305
ON-TIME
Set ON-TIME switch to
1, 5, or 10 minutes.
FEATURES
• Light comes on when motion is detected.
TEST 1 5 10 MIN
• Automatically turns light off.
• Photocel

Summary of the content on the page No. 2

DISASSEMBLE LIGHT FIXTURE INSTALL UNIVERSAL MOUNTING 1. Remove two decorative nuts from light fixture BRACKET cover. For best performance, mount the fixture at least 8 2. Remove cover from base. feet (2.4 m) above the ground. WARNING: Turn power off at circuit Light Fixture Base breaker. 1. Tighten the two fixture screws finger tight. 2. Attach universal mounting bracket to junction box securely with the two screws provided. Junction Box Light Fixture Cover Universal Mounting Decorative Nut B

Summary of the content on the page No. 3

Bare Ground Wire Other Wiring Options This fixture can be wired to control another standard Ground Screw Metal Junction or motion sensing light fixture(s). See the following Box Pigtail (not wiring diagrams for proper connections. supplied) Note: All wiring should be run in accordance with White to White the National Electrical Code through conduit or Fixture Bare another acceptable means. Contact a qualified Black to Black Ground Wire electrician if there is any question as to the suitabi

Summary of the content on the page No. 4

White to White Black to Black to Red TESTING Black and Black 1. Turn on the circuit breaker and light switch. Red to Black 1 Note: Sensor has a 1 / minute warm up period 2 before it will detect motion. When first turned on Ground to 1 wait 1 / minutes. 2 Ground 2. Set the SENSITIVITY switch to the “M” position and the ON-TIME switch to the TEST position. Motion Sensing Controlled Motion Light Sensing Light SENSITIVITY Wiring Motion Sensing Light to Control Another Motion Sensing Light It i

Summary of the content on the page No. 5

The sensor is less sensitive to motion directly 1. Break off the amount of lens shield needed to towards it and more sensitive to motion across block the desired area of coverage. coverage area. 2. Cut desired amount of foam tape needed to adhere the lens shield to the sensor lens. 3. Remove paper backing from one side of cut Motion foam tape and adhere foam tape to inside of lens shield. Motion 4. Remove paper backing from other side of cut foam tape and adhere lens shield to sensor lens.

Summary of the content on the page No. 6

TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Light will not 1. Light switch is turned off. Light stays on 1. There is a heat source like an come on. continuously. air vent, dryer vent, or brightly- 2. Bulbs are loose or burned out. 3. Fuse is blown or circuit breaker painted, heat-reflective surface in is turned off. the coverage area. (Install shield 4. Daylight turn-off is in effect (re- on sensor in the direction of heat check after dark). source.) 2. Sensitivity is

Summary of the content on the page No. 7

Nota: Cuando lo prenda por primera vez espere 1 1 / minutos para que el circuito se claibre. 2 PRUEBA Ponga el interruptor de ON-TIME ON-TIME (DURACIÓN) del detector en TEST Lámpara de portal con (PRUEBA). TEST 1 5 10 MIN detector de movimiento AUTOMATICO Ponga el interruptor de ON-TIME tiempo (ON-TIME) en la posición de 1, 5 ó 10 minutos. TEST 1 5 10 MIN MODO MANUAL PF-4305 El modo manual funciona sólo CARACTERÍSTICAS por la noche porque la luz del • La luz se prende cuando se detecta

Summary of the content on the page No. 8

DESARME EL APARATO DE LUZ INSTALE EL SOPORTE UNIVERSAL 1. Retire las dos tuercas decorativas de la tapa DE MONTAJE del aparato de luz. Para un mejor desempeño, monte el aparato al 2. Retire la tapa de la base. menos a 2,4m del suelo. ADVERTENCIA: Desconecte la energía en Base del aparato el disyuntor. de luz 1. Apriete a mano los dos tornillos del aparato. 2. Sujete bien el soporte universal de montaje a la caja de empalme usando los dos tornillos provistos. Tapa del aparato Caja de emp

Summary of the content on the page No. 9

Conductor desnudo de conexión a tierra Cuando controle aparato(s) de luz adicionales, debe observarse la potencia máxima del detector Tornillo de conexión a tierra Conductor flexible de movimiento de este aparato. Vea en la ilustración (no provisto) de abajo un ejemplo para el cálculo de la potencia Caja metálica máxima de la lámpara. de empalme Potencia nominal Conductor Blanco con máxima de la desnudo del lámpara para el Blanco aparato de luz – aparato para 100 vatios Carga máxima para

Summary of the content on the page No. 10

Es también posible cablear dos luces detectoras de PRUEBA movimiento de modo que cualquiera de ellas encienda 1. Prenda el cortacircuitos y el interruptor de ambas luces al mismo tiempo (sistema de control luz. doble). Se recomienda que sólo personas con amplios Nota: El detector tiene un período de cerca conocimientos de electricidad conecten este tipo de 1 de 1 / minutos de calentamiento antes de 2 configuración. Por favor contacto con nuestro depar- detectar movimiento. Cuando lo pren

Summary of the content on the page No. 11

Cubierta de la placa traslúcida El detector es menos sensible a movimientos 2. Corte la canti- hacia el detector y más sensible a movimientos dad necesaria transversales en el área de cobertura. de cinta es- pumosa que necesita para Movimiento adherir la cu- Movimiento bierta a la placa traslúcida. Placa traslúcida del detector 3. Retire el papel protector de un Detector lado de la cinta espumosa y adhiérala al interior de la cubierta. Lo menos sensible Lo más sensible 4. Retire el papel

Summary of the content on the page No. 12

GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se 1. El interruptor de luz está apagado. La luz se queda 1. Hay una fuente de calor como vento- enciende. 2. Las bombillas están flojas o que- prendida conti- sas de aire, respiradero de secadora, madas. nua-mente. o hay en el área de cobertura una 3. El fusible está quemado o el cor- superficie brillante que refleja calor. (Instale la cubierta en el detector en tacircuitos está apagado. 4. La desconexión de


Alternative user manuals
# User manual Category Download
1 Desa 598-1034-02 User manual Car Video System 0
2 Desa 4E769B User manual Car Video System 0
3 Dynabrade 13400, 13410, 13411 User manual Car Video System 1
4 Sony LMD-1950MD User manual Car Video System 36
5 Sony DVX-11B User manual Car Video System 28
6 Sony NSR-1100 User manual Car Video System 5
7 Sony CDX91 User manual Car Video System 5
8 Sony CDX-GT40U User manual Car Video System 35
9 Sony BVM-L230 User manual Car Video System 23
10 Sony XR-C223 User manual Car Video System 63
11 Sony NSR-1200 User manual Car Video System 6
12 Sony HS-Series SDM-HS73 User manual Car Video System 14
13 Sony SSM-20N5E/20N5U/20N5A User manual Car Video System 1
14 Sony LMD-3250MD User manual Car Video System 0
15 Sony SFA-1000 User manual Car Video System 0