Lennox International Inc. Electric Cooling Package Unit (2/4)SA13 user manual

User manual for the device Lennox International Inc. Electric Cooling Package Unit (2/4)SA13

Device: Lennox International Inc. Electric Cooling Package Unit (2/4)SA13
Category: Humidifier
Manufacturer: Lennox International Inc.
Size: 0.45 MB
Added : 11/30/2013
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lennox International Inc. Electric Cooling Package Unit (2/4)SA13. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lennox International Inc. Electric Cooling Package Unit (2/4)SA13.

For your convenience

If looking through the Lennox International Inc. Electric Cooling Package Unit (2/4)SA13 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lennox International Inc. Electric Cooling Package Unit (2/4)SA13 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lennox International Inc. Electric Cooling Package Unit (2/4)SA13 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lennox International Inc. Electric Cooling Package Unit (2/4)SA13 User manual - Online PDF

Explore the detailed user manual for Lennox International Inc. remarkable creation, Model Electric Cooling Package Unit (2/4)SA13. Gain valuable insights and instructions to maximize your device's capabilities and optimize your user experience. Uncover the full potential of your Lennox International Inc. Electric Cooling Package Unit (2/4)SA13 device through this comprehensive user manual, offering step-by-step guidance and expert tips for effortless operation and enjoyment.

Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lennox International Inc. Electric Cooling Package Unit (2/4)SA13 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lennox International Inc. Electric Cooling Package Unit (2/4)SA13. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION AND
MAINTENANCE INSTRUCTIONS
(2,4)SA13 Series
Electric Cooling Package Unit
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause injury or
property damage. Refer to this manual. For assistance or additional information, consult a
qualified installer or service agency.
WARNING
WARNING
Installation and servicing of air conditioning Sharp metal edges can cause injury. When
equipment can be hazardous due to internal installing the unit, use care

Summary of the content on the page No. 2

Location INSTALLATION These instructions explain the recommended method of The unit is designed to be located outdoors with sufficient installation of the SA electric cooling unit and associated clearance for free entrance to the air inlet and discharge air electrical wiring. openings. The location must also allow for adequate service access. This unit is designed and approved for use as a self- contained air-to-air air conditioning system. The unit must be installed on a solid foundation that w

Summary of the content on the page No. 3

Clearances Minimum Clearance Requirements All units require certain clearances for proper operation and service. Refer to Table 1 for the minimum clearances to combustibles as well as minimum clearances necessary To For For for servicing and proper unit operation. Combustible Proper Service Material Operation In the U.S., units may be installed on combustible floors made from wood or class A, B, or C roof covering material. F" ront 0"4" 8 3 In Canada, units may be installed on combustible floors

Summary of the content on the page No. 4

The supply and return air duct systems should be de- clean or replaced. Dirty filters will reduce the airflow of the signed for the CFM and static requirements of the job. unit. Filters should be sized in accordance with Table 2. They should not be sized by matching the dimensions of the duct connections on the unit. Minimum Required Surface Area Outdoor ductwork must be insulated and waterproofed. for Disposable Filters Equipment is shipped for side ductwork connection. The Filter Area unit can

Summary of the content on the page No. 5

WARNING Electrical Access Unit must be grounded in accordance with national and local codes. Failure to ground unit properly can result in personal injury or death. Heater Power Entry Thermostat Power supply to the unit must be N.E.C. Class 1, and must Entry comply with all applicable codes. A fused disconnect switch should be field provided for the unit. The switch must be Line Voltage separate from all other circuits. Entry If any of the wire supplied with the unit must be replaced, replacem

Summary of the content on the page No. 6

manufacturer’s instructions enclosed with thermostat for general installation procedure. Color-coded insulated wires Heater Kit Accessory Installation (#18 AWG) should be used to connect thermostat to unit. Four wires are required for cooling. Compressor Units are shipped with compressor mountings factory- Heater adjusted and ready for operation. Caution: Do not loosen Blockoff compressor mounting bolts. Heater Compartment Heater Kit Accessory (if used) Access Panel The unit is fully equipped fo

Summary of the content on the page No. 7

OPERATION Sequence of Operation Cooling Upon cooling demand, the thermostat closes circuit R and Y. Closing R and Y closes the unit contactor, starting the compressor and outdoor fan. The thermostat automatically closes R to G circuit which also brings on the indoor blower at the same time. Upon satisfying cooling demand, the thermo- stat will open the above circuits and open the main contactor, stopping the compressor and outdoor fan. If the unit is equipped with a delay timer, the blower will

Summary of the content on the page No. 8

MAINTENANCE Owner Record WARNING Model # _________________________________ ELECTRICAL SHOCK, FIRE, Serial # _________________________________ OR EXPLOSION HAZARD Installation Date ___________________________ Failure to follow the safety warnings exactly could result in dangerous operation, serious Installed by: injury, death, or property damage. Dealer __________________________________ Improper servicing could result in dangerous Address _________________________________ operation, serious in

Summary of the content on the page No. 9

# 48392M005 Figure 9 Page 9 WARNING- ELECTRIC SHOCK HAZARD. UNIT MUST BE GROUNDED W1 & W2 CAN BE USED TO STAGE ELECTRIC HEAT ACCESSORY ON 15 & 20KW MODELS. IN ACCORDANCE WITH NATIONAL AND LOCAL CODES. 5, 7.5 & 10KW HEATER ACCESSORIES FUNCTION OFF W1 ONLY. NOTE: THERMOSTAT IF ANY OF THE ORIGINAL WIRE IS REPLACED, S1 THE SAME SIZE AND TYPE WIRE MUST BE USED. LINE VOLTAGE FIELD INSTALLED. C R W1 Y G USE COPPER CONDUCTOR ONLY, MIN 75°C WIRE. MOTOR SPEED TAPS P-3 RED L MH C NO NC P-1 RED C L1 A15 BLO

Summary of the content on the page No. 10

Limited Warranty August 1, 1997 This warranty gives you specific legal rights and you may have other rights which vary from state/province to state/province. Subject to the limitations stated in this warranty, we warrant to the first buyer for use the residential heating, cooling, or heat pump unit, when installed, operated, and maintained as required by this warranty, to be free of defects in workmanship or material for a period of 5 years in residential installations (1 year in non-residential


Alternative user manuals
# User manual Category Download
1 Lennox International Inc. WB2-17 WP2-18 User manual Humidifier 7
2 Lennox International Inc. WB2-12 User manual Humidifier 0
3 Edelbrock 15015 User manual Humidifier 0
4 Adam Equipment PAS 16E User manual Humidifier 0
5 Adam Equipment 9618 Revision D User manual Humidifier 11
6 AdobeAir CMC641 User manual Humidifier 9
7 AdobeAir MD524 User manual Humidifier 2
8 AdobeAir CMC431 User manual Humidifier 15
9 AdobeAir CMC442 User manual Humidifier 1
10 AdobeAir L900790A User manual Humidifier 1
11 AdobeAir CM240 User manual Humidifier 2
12 AdobeAir CMC632 User manual Humidifier 1
13 AdobeAir MMPC12A User manual Humidifier 2
14 AdobeAir CMC441 User manual Humidifier 4
15 AdobeAir MS628 User manual Humidifier 3