Sanyo CVW-EXA284 user manual

User manual for the device Sanyo CVW-EXA284

Device: Sanyo CVW-EXA284
Category: Tool Storage
Manufacturer: Sanyo
Size: 4.31 MB
Added : 3/18/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo CVW-EXA284. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo CVW-EXA284.

For your convenience

If looking through the Sanyo CVW-EXA284 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo CVW-EXA284 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo CVW-EXA284 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo CVW-EXA284 User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo CVW-EXA284 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo CVW-EXA284. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1






MULTI-DECK FRESH PRODUCE CASES

CVW-EXA184 / CVW-EXA124 CVW-EXA284 / CVW-EXA224

(H: 80 7/8”, L: 96 3/8”) / (H: 80 7/8”, L: 144 5/8”) (H: 84 7/8”, L: 96 3/8”) / (H: 84 7/8”, L: 144 5/8”)



INSTALLATION & SERVICE MANUAL

REMOTE TYPE DISPLAY CASE


2010

Summary of the content on the page No. 2

Activity Safety Precautions In order to prevent any injuries to person, equipment and/or damage to the SANYO Cases, sections requiring additional care to be undertaken will have one or all of the following safety reminders: Red Safety Mark (Safety Mark A) Extreme caution and care must be exercised when conducting this operation to ensure personal A and equipment safety, and to prevent product damage. Failure to exercise extreme caution may result in severe personal injury and/or equi

Summary of the content on the page No. 3

TABLE OF CONTENTS 1 SPECIFICATIONS ..................................................................................................................................................5 1.1 CVW-EXA284 / CVW-EXA224........................................................................................................................5 1.2 CVW-EXA184 / CPW-EXA124.........................................................................................................................6 2 DIMENSIONS

Summary of the content on the page No. 4

6 CARE AND CLEANING GUIDELINES.............................................................................................................21 6.1 EXTERIOR PANELS (DAILY CLEANING)............................................................................................................21 6.2 MIRRORS, FLUORESCENT LAMPS, DRAIN TRAP (MONTHLY CLEANING).........................................................21 6.3 HONEYCOMB ASSEMBLIES (AT LEAST EVERY 3 MONTHS) ................................

Summary of the content on the page No. 5

1 Specifications 1.1 CVW-EXA284 (H: 84 7/8”, L: 96 3/8”) / CVW-EXA224 (H: 84 7/8”, L: 144 5/8”) Model Name CVW-EXA284 CVW-EXA224 General Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh Produce) Cooling Capacity: 1224 BTU/h/ft. (2,880W) 1224 BTU/h/ft. (4,321W) Discharge Air: 34°F (1.11°C) 34°F (1.11°C) Evaporator Temperature: 28°F (-2.22°C) 28°F (-2.22°C) Defrost (Off-cycle) Medium Temperature Medium Temperature Frequency: (times per day) 6, once every

Summary of the content on the page No. 6

1.2 CVW-EXA184 (H: 80 7/8”, L: 96 3/8”) / CVW-EXA124 (H: 80 7/8”, L: 144 5/8”) Model Name CVW-EXA184 CVW-EXA124 General Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh produce) Cooling Capacity: 1146 BTU/h/ft. (2682W) 1146 BTU/h/ft. (4195W) Discharge Air: 34°F (1.11°C) 34°F (1.44°C) Evaporator Temperature: 28°F (-2.22°C) 28°F (-2.22°C) Defrost (Off-cycle) Medium Temperature Medium Temperature Frequency: (time per day) 6, once every 4 hours 6, once ov

Summary of the content on the page No. 7

CVW-EXA284 / CVW-EXA224 2 Dimensions 2.2 Footprint 2.1 External Dimensions ① Waste Outlet ② Electrical Connection * Dimensions given in inches and millimeters (mm in parentheses). ③ Refrigeration Outlet

Summary of the content on the page No. 8

CVW-EXA184 / CVW-EXA124 2.4 Footprint 2.3 External Dimensions ① Waste Outlet * Dimensions given in inches and millimeters (mm in parentheses). ② Electrical Connection ③ Refrigeration Outlet

Summary of the content on the page No. 9

3 Unloading and Carpentry Procedures 3.1 NSF Certification The SANYO Cases described in this manual are built to meet the requirements of American National Standard/NSF International Standard 7. Each SANYO Case bears a nameplate identifying the type of application for which it was certified: Type I display refrigerator/freezer: Intended for use in an area where the environmental conditions are controlled and maintained so that the ambient temperature typically does not exceed 75°F. 3.2

Summary of the content on the page No. 10

3.5 Aligning Cases WARNING SANYO Cases are heavy and bulky, and require at least two people for unloading, moving, and installation. Do not walk on the top of the SANYO Cases. Walking on the top of the SANYO Case may lead to serious injury and/or damage to the SANYO Case. Do not place anything on the top of the SANYO Case or use the top of any SANYO Case for short- or long-term storage. 1. Review layout drawings for spaces where SANYO Cases are to be installed. 2. Based on the layout

Summary of the content on the page No. 11

3.7 Joining Instructions 3.7.1 Applying gasket (for connecting cases or installing side panels). ① Make sure that all SANYO Cases are resting level. ② Make sure that all required parts for joining are present (gasket, bolts, joint covers, nuts, etc.). ③ Remove all Rear Interior Panels, Wire Racks, Deck Pans, and Front Air Grilles from the far right and left ends of each case being joined. ④ Thoroughly clean all surfaces where the gasket will be placed to remove anything that might a

Summary of the content on the page No. 12

3.7.2 Connecting cases. ① Apply gasket as described above. ② Connect cases by using the attached bolts, joint covers, and nuts. Silicone seal Note: Connection point must be silicone sealed. Note: Gasket ends that are open must be sealed off by applying silicone at the installation site. 12

Summary of the content on the page No. 13

① Gasket ② M8 Bolts ③ Side Cover 3.8 Installing Patch Ends ④ Suction Lamp Cover Joint ⑤ M5 Bolts CVW-EXA284/224 CVW-EXA184/124 1. Apply gasket to case body (per previous instructions). 2. If present, remove protective film from inside wall of Patch End. 3. Place Patch End to line up with bolt holes. 4. From inside unit ratchet in M8 & optional M5 bolt into Patch End until secure. Apply silicone sealant inside 5. Apply

Summary of the content on the page No. 14

3.9 Installing Kickplate 1. Align the mounting hole in the Kickplate with the slot in the Kickplate Mounting Bracket on the SANYO Case and tighten accordingly. 14

Summary of the content on the page No. 15

3.10 Installing Handrail and Bumper Attaching the Bumper 1. Attach Maintenance Bumper (length 39-3/8 inches) to Bumper Brackets over the electrical connection box (“Raceway”) on each SANYO Case. The Raceway is located on the right end of each SANYO Case. 2. Attach Full-Length Bumpers between Maintenance Bumpers on separate SANYO Cases, and also between Maintenance Bumpers and Patch Ends. 3. Cut Full-Length Bumpers to size on-site. Cut to correct size so

Summary of the content on the page No. 16

4 Refrigeration, Plumbing & Electrical Procedures 4.1 Piping (Plumbing, Refrigeration) ● U-trap installation Install U-trap referring to the drawing below. Part Name Part Number ① Drain Screen 8FL2162000500 ② O-Ring 8FL2646000100 ③ Drain Trap 8FL2658000200 ● Sealing the refrigerant pipe opening Seal pipe completely. Insufficient sealing may cause the following problems:  Insufficient cooling  Excessive frost

Summary of the content on the page No. 17

4.2 Electrical Data Please refer to Specifications section and nameplate attached to merchandiser for electrical information. 4.3 Electrical – Guidelines & Precautions All wiring and electrical field work must comply with the National Electrical Code (“NEC”) and other applicable local codes. All electrical connections must be made inside the raceway area. 4.4 Wiring 4.4.1 Wiring Color Code WARNING! While undertaking any electrical work, ensure that the cas

Summary of the content on the page No. 18

4.4.2 Wiring Diagram CVW-EXA284/184 CVW-EXA224/124 18

Summary of the content on the page No. 19

5 Operation 5.1 Load Limits In order to maintain proper temperature and unit performance, the Dual Air Curtains in each SANYO Case must remain unobstructed:  Do not stock shelves beyond the marked load limits.  Do not block Honeycombs or Return Air Grilles.  Do not block airflow in any other way (with signs, tools, packages, etc.) Failure to follow these precautions will lead to insufficient temperature control, airflow spoilage, merchandise compromise, and excessive frost. COR

Summary of the content on the page No. 20

Installing FDA/NSF Thermometer Magnet Suggested locations for the thermometer required by NSF/ANSI 7 and the FDA Food Code are indicated above. It is the responsibility of the Purchaser/End User of the SANYO Case to determine the location within the food storage area that best meets these code requirements. 20


Alternative user manuals
# User manual Category Download
1 Sanyo CVW-EXA184 User manual Tool Storage 0
2 Sanyo CVW-EXA124 User manual Tool Storage 1
3 Sanyo CVW-EXA224 User manual Tool Storage 0
4 Addonics Technologies ST34ESA User manual Tool Storage 1
5 ATD Tools ATD-7099 User manual Tool Storage 0
6 ATD Tools ATD7275 User manual Tool Storage 0
7 ATD Tools ATD-7162 User manual Tool Storage 0
8 ATD Tools ATD-7110 User manual Tool Storage 0
9 ATD Tools ATD-7102 User manual Tool Storage 0
10 ATD Tools ITB-B520 User manual Tool Storage 0
11 ATD Tools ATD-5165 User manual Tool Storage 0
12 Avanti WCV42DZ User manual Tool Storage 0
13 Bahco MS7056ENG User manual Tool Storage 2
14 Arrow Storage Products 272.98301.491 White User manual Tool Storage 2
15 Bahco 3126N-LHFR User manual Tool Storage 2