Resumo do conteúdo contido na página número 1 
                    
                        Contents Models covered by this manual 
Electric fencing and your energizer..................................2 This manual covers various energizer models: 
1 J model 1000 / X1 / 401 
Installation .....................................................................2 
2 J model 2000 / X2 / 402 
Operation.......................................................................4 
3 J model 3000 / X3 / 403 
Battery selection and management .................................5 
 
Building a permanent el
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        What are the benefits of an electric fence?  Electric fencing and your energizer  Congratulations on the purchase of your energizer. This An electric fence has many benefits over conventional  fencing:  product has been constructed using the latest technology  and construction techniques. It has been engineered to  • Requires less labour and materials to construct.  give superior performance and many years of service.  • Flexibility to change or add paddocks when  It is important to read these i
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        Installing the energizer inside Installing the energizer outside  The energizer must be installed inside when being The energizer may be installed outside, powered by a  powered by the mains/line power supply. battery.  Warning!   Warning!  Do not power the energizer with the  - Do not use a mains/line power extension lead. mains/line power supply if it is being installed outside.  - Allow 25 mm of clear space around the mains/line  power adaptor.  To install the energizer outside:  To install t
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Operation  Select the pulse speed setting using the pulse speed switch.    Pulse speed switch  Setting Description    Off The energizer is off and is not operating.    Fast with The energizer continues to operate at Fast speed (approximately 1.5 seconds between pulses),    Battery Test but the Indicator lights show the battery level. See Battery test setting on page 5 for an  explanation of the Indicator lights.  Slow The energizer is operating at Slow speed (approximately 2.5 seconds between pu
                    
                    Resumo do conteúdo contido na página número 5 
                    
                          Battery test setting  When the energizer is connected to a battery and the pulse speed switch is set to 'Fast with Battery Test' ( ) the  Indicator lights show the charge level of the battery. The battery test is only relevant when a lead-acid battery is used.  Lights Battery-only installation  Excellent battery charge level (90-100%):    • No action required.  Very good battery charge level (70-90%):    • No action required.  Average battery charge level (40-70%):    • Monitor battery charge 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                          Battery safety  Battery management  • Ensure that the battery is well ventilated when  recharging.  Warning!  Batteries contain harmful chemicals and  when used incorrectly, may cause injury. Observe the • Avoid temperatures greater than 50 °C (120 °F).  guidelines for battery care, maintenance and safety in  • Ensure the battery is not exposed to naked flame or  this manual and in the documentation supplied with  sparks.    your battery.    Building a permanent electric fence  Battery chargin
                    
                    Resumo do conteúdo contido na página número 7 
                    
                          15 m (49') spacing with droppers        Fence designs  Wild animals  Fences can be constructed to suit the type of livestock and 7 wire, 10 m (33') spacing with droppers  materials available.  Discuss with your reseller which  design best suits your needs.  Some suggested fence  configurations are below.  Cattle and horses  10-15 m (33-49') spacing, posts only      End assemblies  Angle stay  Suitable for field gate, high-tension strainer.    After firmly setting the footed strainer in the gro
                    
                    Resumo do conteúdo contido na página número 8 
                    
                          4 Using a voltmeter, ensure that the fence voltage is  Horizontal stay  below 2 kV.  Suitable for field gate, high-tension strainer.  5 Check your earth system. Insert the voltmeter's  Very simple to erect and most suitable as a high tension  earth probe into the ground at the full extent of the  strainer, excellent in areas where the soil gets very wet or  lead, and clip the other lead to the last earth rod.  where heavy frost occurs.  The voltmeter should not read more than 0.3 kV.  Anything
                    
                    Resumo do conteúdo contido na página número 9 
                    
                          This energizer is not intended for use by young children or  Safety considerations  by infirm persons without supervision.  Definition of special terms  Young children should be supervised to ensure that they  do not play with the energizer.  Energizer – An appliance that is intended to periodically  Electric animal fence constructions that are likely to lead  deliver voltage impulses to a fence connected to it.  to the entanglement of animals or persons shall be  Fence – A barrier for animals
                    
                    Resumo do conteúdo contido na página número 10 
                    
                          If connecting leads and electric animal fence wires are Ensure that all mains-operated, ancillary equipment  installed near an overhead power line, the clearances shall connected to the electric animal fence circuit provides a  not be less than those shown in the table below. degree of isolation between the fence circuit and the  supply mains equivalent to that provided by the energizer.  Minimum clearances from power lines for electric animal  fences Protection from the weather shall be provi
                    
                    Resumo do conteúdo contido na página número 11 
                    
                          Servicing  This energizer contains no user serviceable parts. It must be returned to an authorised service centre for repair. This  energizer uses Double Insulation, where two systems of insulation are provided instead of grounding. No equipment  grounding means is provided in the supply cord of a double-insulated energizer, nor should a means for equipment  grounding be added to the energizer. Servicing a double-insulated energizer requires extreme care and knowledge of the  system and should
                    