Resumo do conteúdo contido na página número 1 
                    
                        AHW 164
 
 User manual
HIGH WALL SPLIT AIR CONDITIONER                                                                                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Resumo do conteúdo contido na página número 2 
                    
                         THANK YOU Thank you for choosing this innovative Amcor air conditioner. We suggest  that you keep this manual in a safe place for future reference. It describes the  many benefits and advanced features this unique product has to offer.  Before you use your new air conditioner you should carefully read these  instructions to maximise this product’s performance and the proper  operation. The appearance of the unit that you purchased may differ from the one  described in the manual. This does not 
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        WARNING • Never operate this appliance if it has a damaged cord. Do not lead the cord  over sharp edges.  • A damaged supply cord should be replaced by the manufacturer, its service  agent or a qualified person in order to avoid a hazard.  • Any service other than regular cleaning or filter replacement should be  performed by an authorized service representative. Failure to do so could  result in a loss of warranty.  • Never operate with wet hands.  • Do not attach, hang or stack anything onto t
                    
                    Resumo do conteúdo contido na página número 4 
                    
                         HOW IT WORKS The compressor (6) in the exterior  1 unit compresses the refrigerant into  a high-temperature, high-pressure  gas. When this gas flows along  a the cooling fins of the condenser  2 (7), heat is exuded and the gas  condenses into a liquid, which is led  3 4 to the evaporator (1) in the interior  unit. The liquid expands into a  c b gas at a low temperature and low  6 7 pressure.  5 This gas absorbs the warmth of the  d air in the room, the cooled air is  blown back into the room an
                    
                    Resumo do conteúdo contido na página número 5 
                    
                         REMOTE CONTROL Note: The symbols on your AHW 164 remote control may differ from the ones  used in this manual. LCD display:   Auto mode   Sleep   Cool   Dehumidify   Fan mode   Temperature   Fan mode   Fan speed indicator   Auto (fan, vane control)   Airflow direction   Clock   Order of timer operation   Timer   Timer on   Timer off   Temperature set Using the remote control The remote control signal has a range of up to 8 m. Point the remote  control at the receiver in the interior unit. A bee
                    
                    Resumo do conteúdo contido na página número 6 
                    
                         OPERATION General  • Turn the appliance on with the ON/OFF button . This activates the most  recent setting.  • The ON/OFF button  turns the appliance off; the type of operation set at  that time is stored in the memory.  • The MODE button cycles through the various modes in this order: auto ,  cool , dehumidify , fan .  • The desired temperature is set with the up  and/or down -button,  within the limits of the thermostat: 64 °F – 86 °F (18 °C – 30 °C). Each time  the -button is pressed, the s
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Dehumidify 1. Press the MODE button until the dehumidify symbol   appears. 2. Set the desired temperature with the up  and/or  down -button. 3. The FAN SPEED button does not work in dehumidify mode.  The fan speed will always be low in this mode. Fan mode 1. Press the MODE button until the fan symbol  appears. 2. Set the desired temperature with the up  and/or  down -button. 3. Use the FAN SPEED button to set the fan speed. Sleep mode 1. Press the SLEEP button to reduce the noise level of the ai
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Air flow direction Fins (vertical vanes) Press the IN FLAP button to let the fins turn left/right for  an air flow direction that is comfortable to you. Vanes Press the OUT FLAP button to change the horizontal direction of the air flow, the  vanes take these positions in sequence:   . Usually the auto position  works fine.  Positions  (1) and  (2) are recommended for cool and  dehumidify mode.  After one hour of operation in position  (4) or  (5), the vane  position will revert to level in order
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Emergency start In the event of a problem or missing remote control, the air  conditioner can be operated using the emergency button  under the panel in the interior unit. Open the front panel  and press the button to switch on (in the mode last set) or  to switch off.  FILTERS Turn the appliance off and disconnect the power. B B C A A To open: at the A recesses, pull the To close: press the front part down at  front part up. The front part will stay the sides at B and in the middle at C.  horiz
                    
                    Resumo do conteúdo contido na página número 10 
                    
                         CLEANING Turn the appliance off and disconnect the power. Interior unit Check that the condensation outlet drains properly. Dust regularly with a dry cloth or slightly damp paper towel.  Never use chemicals or solvents. Never spray a liquid in or over the appliance. Exterior unit Remove dirt and keep the air intake and exhaust openings free of leaves, etc.  Cleaning with chemicals may cause damage.  END OF PERIOD OF USE If the air conditioner is not going to be used for an extended period:  • s
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        2 35 BTU/ft .h 2 125 BTU/ft .h INSTALLATION GUIDELINES Which Air Conditioner is best suited for your room? Many windows Size of the room Much sunshine (floor area) (conservatory) 2 115 ft 2 225 ft Less windows  Less sunshine 2 400 ft 2 575 ft Cooling capacity 8000 11000 14000 17000 20000 BTU/h The most suitable air conditioner depends on the surface area, sun location, window area,  presence of heat sources (lamps, appliances, number of people etc.). Take this into account! Rule of thumb, in ave
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Point of attention for the installation of electric components  • HACR type breaker should be utilized along with proper installation.  • Be sure to use the applicable voltage and cables or wires for the unit to be  installed, before making the connections.  • Read the prompts at the terminal board for wiring. Make sure the wiring is  done correctly.  • Pay attention to the poles of the signal terminal and connect the terminals  to match the identification numbers.  • The connecting wires and th
                    
                    Resumo do conteúdo contido na página número 13 
                    
                         TROUBLE SHOOTING Cases requiring immediate contact with your dealer:  • breaker or fuse breaks off often.  • malfunction of TV, radio or similar devices.  • switch does not result in sure performance  • abnormal noise during operation.  • if a faulty operation does not disappear after restart (after having waited for  3 minutes). Check the following before requesting after sales service from your dealer: The air conditioner does Is the unit connected to a power supply? not operate at all. Has t
                    
                    Resumo do conteúdo contido na página número 14 
                    
                         RATING LABELS INDOOR OUTDOOR UNIT UNIT See barcode See barcode AHW 164 230 V 60 Hz 1 Ph AHW 164 230 V 60 Hz 1 Ph Model Serial number Power supply Model Serial number Power supply 1.2 kW 9.4 A 6.4 A 15 A 5.1 kW 13 BTU/h W IP 20 Minimum Maximum 18000 BTU/h Rated power Rated current circuit amperage current protection Cooling capacity SEER Protection class 5.1 kW 2.4 / 4 MPa o 3 18000 BTU/h 348/580 PSIG 13 BTU/h W 64-86 F 1040 m /h o R410A Pressure range 18-30 C 36700 cu.ft/h Cooling capacity SEER
                    
                    Resumo do conteúdo contido na página número 15 
                    
                         NOTES 15                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Hong Kong Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852 2997 6865 Fax: +852 2997 6091 Email: amcorhk@amcorgroup.com United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: +44 20 8560 4141 Fax: +44 20 8232 88141 Email: amcoruk@amcorgroup.com USA Amcor Inc. 685A Gotham Parkway, Carlstadt, New Yersey 07072, United States of America Tel: +1 201 460 8100 Fax: +