Resumo do conteúdo contido na página número 1 
                    
                         
CHAPTER1
Product Overview
This chapter provides an overview of the Cisco XR 12416 router. It contains 
physical descriptions of the router hardware and major components, as well as 
functional descriptions of the hardware-related features.
Physical and Functional Description of Router
The Cisco XR 12416 router chassis is a sheet-metal enclosure that houses router 
components. The major components consist of three power supplies, upper and 
lower line card cages, a switch fabric card cage, and 
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        Chapter 1      Product Overview Physical and Functional Description of Router   � Upper Line card and Route Processor card cage—Has 8 user-configurable  slots that support a combination of line cards, a route processor (RP), and an  alarm card. See the “Alarm Card and Line Card Overview” section on  page 1-18 for additional information. � Switch fabric card cage—Located behind the air filter door, this card cage  contains 5 slots for the switch fabric card set. The switch fabric card set is  mad
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        ROUTE PROCESSOR FAST ETERNET OC-12/STM-4 ATM OC-48/STM-16-SCPOS DOWN CDHNT CD LOOP RA LA 12DS3–SMB  P/H/F DOWN CDHNT CD LOOP RA LA 6DS3–SMB  P/H/F Q OC-3/STM-POS ALARM ALARM ENABLED FAIL EJECT SLOT-1 SLOT-0 RESET AUX CONSOLE COLL LINK RX TX 0 RJ-45 ACTIVE CARRIER RX CELL MII 0 ACTIVE CARRIER RX PKT 1 ACTIVE CARRIER RX PKT CRITICAL MAJOR 2 MINOR ACTIVE CARRIER RX PKT ACO/LT 3 ACCARRIER TIVE RX PKT FAIL ENABLED CSC 0 1 SFC 0 1 2 ACTIVE CARRIER RX PKT TX 0 RX TX 1 RX TX 0 TX RX 2 RX TX 1 TX RX 3 RX
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Chapter 1      Product Overview Physical and Functional Description of Router   AC and DC Power Subsystems A router ships with either an AC or DC powered system. Source power connects  to the power shelf at the back of the chassis which route power to the power  supplies, also referred to as power entry modules (PEMs). Standard AC Power Shelf The standard AC-input power subsystem consists of a single-level AC-input  power shelf that house three AC power supplies which supply full redundant  powe
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        PWR OK PWR OK PWR OK FAULT FAULT FAULT TEMP TEMP TEMP I LIM I LIM I LIM Chapter 1      Product Overview Physical and Functional Description of Router   Figure 1-2 Standard AC-Input Power Subsystem  Caution A router equipped with the standard AC power subsystem must be operated with  three power supplies installed in the power shelf at all times for electromagnetic  compatibility (EMC).  AC power to the router is provided through power cords connected from AC  power outlets to connectors on back 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Chapter 1      Product Overview Physical and Functional Description of Router   Optional AC Power Shelf The power subsystem consists of a double-level AC-input power shelf with bays  for 4 AC-input power supplies. Figure 1-4 shows the optional power shelf. It  attaches to the top of the router chassis and is secured to the chassis the same way  as the standard AC-input power shelf. Note A router equipped with the optional AC-input power subsystem stands 77.5 inches  (196.85 cm) tall and does not
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        PWR OK PWR OK FAULT FAULT TEMP TEMP I LIM I LIM PWR OK PWR OK FAULT FAULT TEMP TEMP I LIM I LIM Chapter 1      Product Overview Physical and Functional Description of Router   Figure 1-4 Optional AC-Input Power Subsystem Caution A router equipped with the optional AC power subsystem must be operated with  4 power supplies installed in the power shelf at all times for electromagnetic  compatibility (EMC). Cisco XR 12416 Router Installation Guide OL-13833-01 1-7 27837                              
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Chapter 1      Product Overview Physical and Functional Description of Router   AC power to the router is provided through power cords connected from AC  power outlets to the connectors on the back of the power shelf as shown in  Figure 1-5. Figure 1-5 Optional Power Shelf AC-Input Connections Power cords Cisco XR 12416 Router Installation Guide OL-13833-01 1-8 27838                                                                                                                                   
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Pwr Ok Fault Temp OC Chapter 1      Product Overview Physical and Functional Description of Router   AC Power Supplies Each AC PEM converts 200 to 240 VAC into -48 VDC, which is distributed  through the chassis backplane to all cards, RPs, and the blower modules. Figure 1-6 identifies the components of a 2500 W AC power supply. Figure 1-6 2500 W AC Power Supply Components 1 2 1 Ejector handle 2 Captive screw Cisco XR 12416 Router Installation Guide OL-13833-01 1-9 Pwr Ok Fault Temp OC 129495    
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Chapter 1      Product Overview Physical and Functional Description of Router   The status LEDs on an AC PEM provide information about the current operational  status of the power supply: � PWR OK (green)—Indicates that the power supply module is operating  normally. � FAULT (yellow)—Indicates that a fault is detected within the PEM. � TEMP (yellow)—Indicates the PEM is in an overtemperature condition and  shutdown has occurred. � ILMI (yellow)—Indicates the PEM is operating in a current-limitin
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        PWR OK PWR OK PWR OK PWR OK FAULT FAULT FAULT FAULT TEMP TEMP TEMP TEMP Chapter 1      Product Overview Physical and Functional Description of Router   In the DC-input power configuration: � Modules A1 and B1 provide redundant power for system load zone 1 (the  upper blower module and the upper card cage). � Modules A2 and B2 provide redundant power for system load zone 2 (the  switch fabric card cage, the lower card cage, and the lower blower module). Figure 1-7 DC-Input Power Shelf Caution A r
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Chapter 1      Product Overview Physical and Functional Description of Router   Figure 1-8 DC-Input Power Shelf Connections  B1 A1- A1+ A2- A2+ B2+ B2- B1+ B1- Ground Cover with slotted screw hole;  fastens to standoff in middle of  cable connection area Cisco XR 12416 Router Installation Guide OL-13833-01 1-12 27964                                                                                                                                                                                      
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        PWR OK FAULT TEMP OC Chapter 1      Product Overview Physical and Functional Description of Router   DC Power Supplies Each DC PEM operates from a nominal source DC voltage of –48 to –60 VDC  and requires a dedicated 60 amp service. Figure 1-9 identifies the components of a 2400 W DC power supply. Figure 1-9 2400 W DC Power Supply Components 2 1 3 4 PWR OK FAULT TEMP OC 1 Handle 3 Ejector lever 2 Fan 4 Power switch Cisco XR 12416 Router Installation Guide OL-13833-01 1-13 129494                 
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Chapter 1      Product Overview Chassis Card Cages   The status LEDs on a DC PEM provide information about the current operational  status of the power supply: � PWR OK (green)—Indicates that the power supply module is operating  normally. � FAULT (yellow)—Indicates that a fault is detected within the PEM. � TEMP (yellow)—Indicates the PEM is in an overtemperature condition and  shutdown has occurred. For additional information about troubleshooting DC PEMs, see the  “Troubleshooting a DC Power 
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        Chapter 1      Product Overview Chassis Card Cages   Lower Card Cage The lower card cage also has eight user-configurable slots that support additional  line cards, an alarm card, and an optional, redundant RP.  Note The lower card cage is an inverted, or head-down, copy of the upper card cage,  which means that cards are installed in an inverted or head-down orientation. The  orientation of the slots is opposite that of the upper card cage. � Slot 8—The far left slot is reserved for an optional
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Chapter 1      Product Overview Switch Fabric Overview   Switch Fabric Overview The switch fabric provides synchronized gigabit-speed connections between line  cards and the RP. The switch fabric card cage is located behind the air filter door  and consists of 2 clock and scheduler cards (CSCs) and 3 switch fabric cards  (SFCs). One CSC and the 3 SFCs are the active switch fabric; the second CSC  provides redundancy for the other 4 cards. Note 10-Gbps switch fabrics do not operate in 1/4-bandwid
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Chapter 1      Product Overview Switch Fabric Overview   Caution Do not remove the blank filler panel unless instructed to do so by a Cisco support  representative. Clock Scheduler Cards Clock scheduler cards provide the following functionality: � Scheduler—Handles all scheduling requests from the line cards for access to  the switch fabric. � System clock—Supplies the synchronizing signal to all SFCs, line cards, and  the RP. The system clock synchronizes data transfers between line cards or  b
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        Chapter 1      Product Overview Alarm Card and Line Card Overview   Alarm Card and Line Card Overview This section provides general information about alarm cards, line cards and types  of route processors installed in the router. Note The Cisco XR 12416 router supports online insertion and removal (OIR), which  allows you to remove and replace a card while the router remains powered on. Alarm Cards The router is equipped with 2 alarm cards: � One alarm card occupies the dedicated far left slot o
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        Chapter 1      Product Overview Alarm Card and Line Card Overview   – ENABLED (green)—The alarm card is operational and functioning  properly. – FAIL (yellow)—The alarm card in that slot is faulty. � A pair of status LEDs that correspond to each of the 5 card slots in the switch  fabric card cage (2 CSCs and 3 SFCs): – ENABLED (green)  On—The card installed in that slot is operational and functioning  properly. Off—Either the slot is empty or the card installed in that slot is faulty. – FAIL (ye
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        Chapter 1      Product Overview Route Processor   Line Cards Up to 15 Cisco XR 12416 router line cards can be installed in the routers upper  and lower card cages to support a variety of physical network media. Ports and  connectors on the line card front panels provide interfaces for external  connections. Line cards communicate with the RP and exchange packet data with  each other through the switch fabric cards. Caution Any unoccupied card slot in the upper and lower card cages must have a bl