Resumo do conteúdo contido na página número 1 
                    
                        DR-1200/1500/1800/2000EX
Rugged Dome Camera 
 
 
 
                                                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Resumo do conteúdo contido na página número 2 
                    
                          © 2002 Kalatel, a GE Interlogix company  All Rights Reserved.  Any GE Interlogix, Kalatel division, software  This equipment has been tested and  supplied with GE Interlogix, Kalatel division,  found to comply with the limits for a  products is proprietary and furnished under  Class A digital device, pursuant to part  license and can be used or copied only in  15 of the FCC Rules. These limits are  accordance with the terms of such license.  designed to provide reasonable  protection against h
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        Rugged Dome Camera Installation Manual Table of Contents     TABLE OF CONTENTS  BEFORE YOU BEGIN ...............................................................4  1 PREPARING THE HOUSING AND CAMERA ............................5  1.1 RETROFITTING WITH THE UTP MODULE......................6  2 MOUNTING THE UNIT .........................................................8  2.1 SURFACE-MOUNTING THE HOUSING ...........................9  2.2 FLUSH-MOUNTING THE HOUSING..............................11  2.3
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Before You Begin Rugged Dome Camera Installation Manual    BEFORE YOU BEGIN  Read these instructions before installing or operating this product.  Note: This installation should be made by a qualified service person and should conform to  local codes.  This manual provides installation and operation information. To use this  document, you must have the following minimum qualifications:  • A basic knowledge of CCTV systems and components  • A basic knowledge of electrical wiring and low-voltage e
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Rugged Dome Installation Manual Preparing the Housing and Camera     1 PREPARING THE HOUSING AND CAMERA  Using the provided Allen wrench, loosen the tamper-resistant housing  cover screws.  • If your unit has the factory-installed flying lead with coaxial video  cable, proceed to section 2 to mount the unit.  • If your unit has the factory-installed UTP module, ensure that the  jumpers illustrated in Figure 2 are disconnected. Then proceed to  section 2 to mount the unit.  • To retrofit your uni
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Preparing the Housing and Camera Rugged Dome Installation Manual    1.1 RETROFITTING WITH THE UTP MODULE  To put the unit in UTP mode see Figure 2 and perform the following.  1) Disconnect the flying lead from the PC assembly and remove it  from the housing.   2) Disconnect the jumpers on the PC assembly.    Connected   jumpers  Disconnected   jumpers    Figure 2. Disconnecting jumpers on the PC assembly to enable the UTP module    6 1038346B / February 2003                                      
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Rugged Dome Installation Manual Preparing the Housing and Camera     To install the UTP module see Figure 3 and Figure 4 and perform the  following.  M3.5x3 fillister- head screw     Figure 3. Inserting the mounting screw into the UTP module  1) Insert the M3.5x3 fillister-head mounting screw into the middle right  hole of the module.  2) Screw the UTP module onto the UTP module mounting post  (Figure 1) in the housing.      Connection to the PC assembly     Cable to terminal board  Unshielded t
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Mounting the Unit Rugged Dome Installation Manual    2 MOUNTING THE UNIT  Cables should be prepared and accessible at the mounting location.      Figure 5. Surface-mount  Figure 6. Flush-mount   To surface-mount the housing see section 2.1. To flush-mount the  housing see section 2.2.     Pendant mount  3/4-in. pipe NPT (not provided)  Extended pendant mount  Wall mount    Figure 7. Pendant- or wall-mount brackets  To mount the unit on a pendant- or wall-mount bracket see section 2.3.  8 1038346
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Rugged Dome Installation Manual Mounting the Unit     2.1 SURFACE-MOUNTING THE HOUSING  To surface-mount the housing, see Figure 8 and perform the following.   Mounting   surface  Anchors  Outer plate  Inner plate  M4x20 truss-head  tapping screws  (3)   M4x12 pan-head  double-washer    screws (3) (through housing  base)    Figure 8. Surface-mounting the housing  Note: Feed the cables through the mounting surface, plates, and housing at the  appropriate time depending on whether you are using th
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Mounting the Unit Rugged Dome Installation Manual    5) If necessary, cut out the outlined back cable entry hole.  To mount the outer plate, perform the following.  1) Install the provided mounting anchors in the mounting holes.  2) Mount the plates to the anchors in the mounting surface using the  M4x20 truss-head tapping screws.   To install the housing perform the following.  1) Let the housing cover drop down and rest on the hinge.  2) Attach the housing to the inner plate using the M4x12 pa
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        Rugged Dome Installation Manual Mounting the Unit     2.2 FLUSH-MOUNTING THE HOUSING  To flush-mount the housing, see Figure 9 and perform the following.  Back plate  Ceiling panel  Outer plate      Inner plate  M5x20 pan-head  double-washer  screws (3)  M4x12 pan-head  double-washer  screws (3)  (through housing  base)    Figure 9. Flush-mounting the housing  Note: Feed the cables through the ceiling panel, plates, and housing at the appropriate  time depending on whether you are using the flyi
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Mounting the Unit Rugged Dome Installation Manual    Note: Ensure that you trace the back of the outer plate: this is the side with the  smaller diameter. If you trace the diameter of the front of the plate, your mounting  hole will be too large.  3) Trace the outline of the back of the outer plate onto the ceiling  panel.  4) Use the traced outline as a guide to cut out the mounting hole.  To install the back and outer plates perform the following.  1) From the inside of the back plate, insert 
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Rugged Dome Installation Manual Mounting the Unit     2.3 USING PENDANT- AND WALL-MOUNT BRACKETS  To install the housing on pendant-mount, extended-pendant-mount, or  wall-mount brackets, perform the following.  Note: The extended-pendant-mount bracket is extended with a piece of installer-provided  3/4-inch (1.9 cm) pipe that has standard NPT threads. The extension should be in the  bracket before performing the installation procedure.   Note: Feed the cables through the mounting surface, brack
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Mounting the Unit Rugged Dome Installation Manual    1) Remove the three mounting screws from the pendant of the  mounting bracket.  2) Let the housing cover drop down and rest on the hinge.  3) Feed the cables through the bracket.  4) Slide the housing into the pendant of the mounting bracket.  5) Line up the three holes on the bottom of the housing with the three  corresponding holes in the bracket.  6) Attach the housing to the bracket using the three mounting screws.  To make cable connectio
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        Rugged Dome Installation Manual Making Cable Connections     3 MAKING CABLE CONNECTIONS  To make cable connections using the flying lead with coaxial cable see  section 3.1. To make cable connections using UTP see section 3.2.  3.1 COAXIAL CABLE  To make remaining cable connections see Figure 11.      Coaxial video out Power (12 VDC or 24 VAC)  Figure 11. Camera cables  3.2 UTP CABLE  To make the remaining power cable connections see Figure 12.    Push terminals  Video ground  Video out  Power –
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Adjusting the Camera Rugged Dome Installation Manual    4 ADJUSTING THE CAMERA  To adjust the camera focus see section 4.1. To make phase adjustments  see section 4.2. To make auto-iris lens adjustments see section 4.3.  4.1 FOCUS  1) Loosen the zoom ring thumbscrew.   2) Turn the zoom ring to set the desired zoom.   3) Tighten the zoom ring thumbscrew.  4) Loosen the focus ring thumbscrew.  5) Turn the focus ring to set the desired focus.  Note: To keep the camera in focus, you might have to ad
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Rugged Dome Installation Manual Adjusting the Camera        CAUTION:  The phase adjustment must be made by a qualified service person  or installer.  Line-lock is automatic when the camera is connected to a 24 VAC power  supply. If two cameras are connected to different AC supplies with  different phases, the cameras can be synchronized. Synchronize the  cameras by using a dual-trace oscilloscope to observe the video output  signal (V-rate) of the camera and by adjusting the line-lock phase cont
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        Adjusting the Camera Rugged Dome Installation Manual    4.3 AUTO IRIS LENSES  For auto iris lenses, use an insulated adjustment tool to adjust the DC  level with the blue pot on the PC assembly (Figure 14). Proper  adjustment will ensure the correct exposure depending on the camera’s  situation and the lighting levels.   To set the light level at which the camera switches between daylight and  IR mode, see Figure 14 and perform the following.    DC auto iris level  adjustment pot                
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        Rugged Dome Installation Manual Adjusting the Camera     4.4 SETTING THE DAY/NIGHT CAMERA SWITCH LEVEL  The Day/Night Rugged Dome includes a lens that provides a true-color  picture during daylight hours. The camera includes a photocell that  detects when low-light levels occur and, with the removal of a filter from  the lens, instigates infrared (IR) operation. IR operation provides a true  black and white picture during low light conditions.  To set the light level at which the camera switches
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        Closing the Housing Rugged Dome Installation Manual    5 CLOSING THE HOUSING  Shut the housing cover and use the provided Allen wrench to tighten the  housing cover screws. Ensure that the cover is tightened securely to  maintain the unit’s IP66 ratings.  20 1038346B / February 2003