Resumo do conteúdo contido na página número 1 
                    
                         
 
 
 
 
 
 
 
 
  
 
 
IBM BladeCenter S  IBM BladeCenter E 
Distributed, small office, Best energy efficiency, 
easy to configure best density 
 
 
 
 
IBM BladeCenter T IBM BladeCenter H IBM BladeCenter HT 
Ruggedized High performance Ruggedized, 
high performance 
 
 
 
 
 
 
IBM BladeCenter Chassis 
Product Guide 
September 2008                                                                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 2 
                    
                                    Table of Contents    Overview 3  BladeCenter Chassis Positioning 4  IBM BladeCenter Chassis 6  BladeCenter I/O Modules 30  Rack vs. Blades Positioning 33  Citrix Solution 37  Virtualization Solution 38                         2. Please see the Legal Information section for important notices and information.                                                                                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 3 
                    
                          Overview  You need to make IT decisions that will drive business success. You face management challenges and technological  complexity such as space constraints, power and cooling limitations, heterogeneous environments and I/O connectivity  issues. IBM brings together the widest choice of compatible chassis, blade servers, storage and networking offerings and  solution providers in the industry to help you build an open and flexible IT environment. And regardless of the size of your  business
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        BladeCenter Chassis Positioning  Which BladeCenter Chassis is Right for You?  IBM offers five different BladeCenter chassis built across a consistent architecture. The chassis are targeted to meet your  unique requirements, yet all encompass the same commitment to excellence. Remember, BladeCenter blades and  switches can be seamlessly moved between chassis. This offers investment protection and incredibly flexible, mix-and- match deployment choices.    IBM BladeCenter S  BladeCenter S is the ch
                    
                    Resumo do conteúdo contido na página número 5 
                    
                          IBM BladeCenter HT  BladeCenter HT is a new telecommunications-optimized version of IBM  BladeCenter H. It delivers outstanding core network performance and high-speed  connectivity.   • Up to 12 blades, 12U design  • Non-traditional environment support—NEBS 3/ETSI (planned)  • Greatest I/O flexibility with up to 8 switch bays  • Supports 30mm blades with up to 8 ports  • Supports 10Gb Ethernet and 4X InfiniBand   • Ruggedized chassis  • AC and DC power input  • Planned availability through 20
                    
                    Resumo do conteúdo contido na página número 6 
                    
                             IBM BladeCenter Chassis Today’s data center environment is tougher than ever. You are looking to reduce IT cost,  Product Overview  complexity, space requirements, power consumption and heat output, while increasing    ® ® flexibility, utilization and manageability. Moving to innovative IBM BladeCenter as your    IT foundation can help you accomplish all of these goals.      The IBM BladeCenter family tightly integrates servers, storage, networking, I/O and   applications, allowing you to b
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Selling Features Price/Performance  • The extremely high degree of integration in the various BladeCenter chassis reduces  the need for server components, replacing numerous fans, KVM and Ethernet cables,  power supplies, external switches and other components with fewer shared hot- swap/redundant components in the BladeCenter chassis themselves. This integration also  can greatly reduce the amount of power consumed and heat produced, relative to an  equivalent number of 1U servers—or competitiv
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        capabilities by “surfacing” pertinent information about your blade server. The easy-to-use  Deployment Wizard also provides step-by-step installation instructions and offers  automated deployment capabilities.  • Each BladeCenter chassis includes an Advanced Management Module (AMM). The  AMM boosts administrator productivity and reduces skill level requirements, which can  help reduce costs, improve overall productivity and make administration easier. Unlike  traditional servers and some competi
                    
                    Resumo do conteúdo contido na página número 9 
                    
                          BladeCenter S provides:  • A choice of installation methods — Designed for either rack or deskside use with the  optional Office Enablement Kit, it’s ideal for offices or remote/branch locations.  • Integrated compute blades, SAN storage, and switches in one chassis — In addition  to six blade servers, the BladeCenter S also supports 12 shared hot-swap 3.5-inch  SAS, SATA, or Nearline SAS HDDs, and four integrated switches (two Ethernet, plus  two Ethernet, Fibre Channel, SAS, or RAID SAS Cont
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        / 1400W high-efficiency hot-swap/redundant power modules (upgradeable to four),  capable of handling the power needs of the entire chassis. Many servers use power  supplies with an efficiency level of approximately 65-75%. Because BladeCenter S uses  power supplies that are at least 90% efficient, much less power is wasted as heat. Not  only is more power available for chassis use, there is less power wasted as excess heat  output. Two additional power modules must be installed when the second S
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        come standard with the chassis. They are capable of providing efficient cooling for up to 14  blades. These modules replace the need for each blade to contain its own fans. The two  blowers are more energy efficient than dozens or hundreds of smaller fans would be, and  they offer many fewer points of potential failure.   • Four module bays for Power Modules — BladeCenter E ships with two 2000W high- efficiency hot-swap/redundant power modules (upgradeable to four), capable of  handling the powe
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        modules interface with all of the blade servers in the chassis and alleviate the need for  external switches or expensive, cumbersome, and error-prone cabling. All connections are  done internally via the midplane. Two module slots are reserved for hot-swap/redundant  Gigabit Ethernet switch modules. Two slots support either high-speed bridge modules  or legacy Gigabit Ethernet, Myrinet, Fibre Channel, InfiniBand and other switch  modules. Two slots are dedicated for bridge modules. Four additio
                    
                    Resumo do conteúdo contido na página número 13 
                    
                         • NEBS Level 3/ETSI-tested — Designed for the Network Equipment Provider  (NEP)/Service Provider (SP) environment. Also ideal for government/military, aerospace,    industrial automation/robotics, medical imaging and finance. Certified testing by   Underwriters Laboratories of the BladeCenter HT chassis is in progress; when complete, it  will be covered under a UL-certified NEBS Level 3/ETSI test report.    • Support for Carrier-Grade Linux — Several distributions are supported, include SUSE   
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        switches. (And the integrated switches may be less expensive than external, self-powered  switches.) Plus, the number of power distribution units (PDUs) needed per rack may  be lessened, because there are fewer discrete devices to have to plug in. In addition,  because all the blades are connected to all the switches inside the chassis, there is no  need for external Ethernet or other communication cables to connect the blades  and switches. (Only the few cables needed to connect the switches to
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        • Two hot-swappable Media Trays each contain two external USB 2.0 ports, a light path  diagnostic panel, and support a 1GB/4GB compact flash (CF) option — The media  trays are shared by all the blades in the server. This reduces unnecessary parts (and  reduces the number of parts than can fail). In the event of a failure of the Media Tray the  tray can be swapped for another. While the tray is offline, the servers in the chassis can  remotely access the Media Tray in another chassis. The diagnos
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        • Local update of BMC firmware  • Firmware firewall  • Support for IPMI v2.0 compliant management software (e.g., xCAT)  • Other mandatory and optional IPMI BMC functions  Other systems management features offered for the combination of blade server and  chassis include:  • Predictive Failure Analysis for system processors, memory and HDDs, as well as chassis  switch modules, blower/fan modules and power modules  • Web-based out-of-band control  • Windows “blue screen” capture  • Remote virtual 
                    
                    Resumo do conteúdo contido na página número 17 
                    
                          • Network attached storage (NAS) — Provides a large capacity, highly available and secure  ™ environment for storing mission-critical data. The System Storage N series attaches to IBM    BladeCenter using integrated Ethernet switch modules.    • Storage area network (SAN) — Offers iSCSI and Fibre Channel SANs for high-   performance, block-level storage solutions. With IBM System Storage DS3000, DS4000,  DS6000 and DS8000, IBM can help you create an easy-to-deploy storage solution for your    
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        Additional services include hardware warranty upgrades and factory-installed Product  Customization Services (PCS), such as asset tagging, hardware integration, software  imaging and operating systems personalization.  IBM offers extensive technical support by phone and via the Web. Support options include  links to forums/newsgroups, problem submission, online shopping support, service offerings,  device drivers for all IBM product lines, software downloads and even upcoming technical  seminar 
                    
                    Resumo do conteúdo contido na página número 19 
                    
                          BladeCenter S Chassis Specifications  Machine type 8886-1Ex/Y, 1Mx/1MY, AC1  Rack form factor 7U  # of DVD/CD drives standard 1 DVD-RW/CD-RW (in Media Tray)  # of diskette drives standard None (USB-attached)  # of internal (chassis-based) H/S SAS  12 (3.5-inch)  HDDs supported  # of Media Tray module bays 2  Internal tape drives supported None (SAN-attached)  Internal hot-swap disk drive support 12 hot-swap SAS/SATA/Nearline SAS (mix-and-match)  Internal disk storage capacity 3.6TB (using 12 3
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        BladeCenter S Chassis Specifications  Length of limited warranty 3 years (parts and labor) onsite    BladeCenter E Chassis Images  Front View Rear View Empty Module Slots  CD-ROM Drive  Ethernet Switch Module  Media Tray  Management Module  Blower  Module  Blade  Floppy Drive  Server  Midplane Redundant Management  Module Slot  Other Blade Servers  Blower  Module  Power Modules   Empty Power  Light Path Diagnostics  Module Slots  Panel  Interior View   Diagnostic LEDs USB Port CD-ROM Drive Flopp