Resumo do conteúdo contido na página número 1 
                    
                        TigerStack 100
Stackable Fast Ethernet Switch
◆ 24 100BASE-FX MT-RJ ports
◆ Optional 100BASE-FX or 1000BASE-X modules
◆ Optional stack module for linking up to four units
◆ 8.8 Gbps of aggregate switch bandwidth
◆ Support for redundant power unit
◆ Up to five port trunks per switch
◆ Port mirroring for non-intrusive analysis
◆ QoS support for two-level priority
◆ Full support for IEEE 802.1Q VLANs
◆ IP Multicasting with IGMP Snooping
◆ Manageable via console, Web, SNMP/RMON
Management Guide
SMC6
                    
                    Resumo do conteúdo contido na página número 2 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        TigerStack 100 Management Guide From SMC’s Tiger line of feature-rich workgroup LAN solutions 38 Tesla Irvine, CA 92618 November 2002 Phone: (949) 679-8000 Pub. # F2.47 150200025700A R01                                                                                                                                                                                                                                                                                                                          
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Information furnished by SMC Networks, Inc. (SMC) is believed to be  accurate and reliable. However, no responsibility is assumed by SMC for its  use, nor for any infringements of patents or other rights of third parties  which may result from its use. No license is granted by implication or  otherwise under any patent or patent rights of SMC. SMC reserves the right  to change specifications at any time without notice. Copyright © 2002 by SMC Networks, Inc. 38 Tesla Irvine, CA 92618 All rights r
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        LIMITED WARRANTY Limited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be  free from defects in workmanship and materials, under normal use and service, for the  applicable warranty term. All SMC products carry a standard 90-day limited warranty from  the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion,  repair or replace any product not operating as warranted with a similar or functionally  equivalent product, during the applicable 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        LIMITED WARRANTY LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION,  MAINTENANCE OR USE OF ITS PRODUCTS. SMC SHALL NOT BE LIABLE  UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE  ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY  CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER  INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR  ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY  ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD. LIMITATION OF
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        TABLE OF CONTENTS 1 Switch Management  . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Required Connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Console Port (Out-of-Band) Connections  . . . . . . . . . . . . . . . . . 1-4 In-Band C
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        TABLE OF CONTENTS Using a Mirror Port for Analysis . . . . . . . . . . . . . . . . . . . . . . . . 2-44 Configuring Port Trunks  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45 IGMP Multicast Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-48 Configuring IGMP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49 Configuring Broadcast Storm Control . . . . . . . . . . . . . . . . . . . . 2-50 Configuring Bridge MIB Extensions . . . . . . . . 
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        TABLE OF CONTENTS Expansion Slot  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 IP Configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 SNMP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 SNMP Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 Trap Managers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        TABLE OF CONTENTS Configuring IGMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43 IP Multicast Registration Table  . . . . . . . . . . . . . . . . . . . . . . . . . 3-44 Port Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45 Port Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45 Port Configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46 Po
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        TABLE OF CONTENTS B Pin Assignments  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Console Port Pin Assignments  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 DB-9 Port Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Console Port to 9-Pin COM Port on PC  . . . . . . . . . . . . . . . . . . B-2 Console Port to 25-Pin DTE Port on PC . . . . . . . . . . . . . . . . . . B-2 Glossary Index vii                                         
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        TABLE OF CONTENTS viii                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        CHAPTER 1 SWITCH MANAGEMENT Configuration Options For advanced management capability, the TigerStack 100 management  agent provides a menu-driven system configuration program. This  program can be accessed by a direct or modem connection to the serial  port on the rear panel (out-of-band), or by a Telnet connection over the  network (in-band). The management agent is based on SNMP (Simple Network Management  Protocol). This SNMP agent permits the switch to be managed from any  PC in the network 
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        SWITCH MANAGEMENT Required Connections Console Port (Out-of-Band) Connections Attach a VT100 compatible terminal or a PC running a terminal emulation  program to the serial port on the switch’s rear panel. Use the null-modem  cable provided with this package, or use a null modem connection that  complies with the wiring assignments shown in Appendix B of this guide.  When attaching to a PC, set terminal emulation type to VT100, specify the  port used by your PC (i.e., COM 1~4), and then set comm
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        REQUIRED CONNECTIONS In-Band Connections Prior to accessing the Network Management Module via a network  connection, you must first configure it with a valid IP address, subnet  mask, and default gateway using an out-of-band connection or the  BOOTP protocol.  After configuring the switch’s IP parameters, you can access the on-board  configuration program from anywhere within the attached network. The  on-board configuration program can be accessed using Telnet from any  computer attached to the
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        SWITCH MANAGEMENT Factory Defaults The default settings for switch configuration parameters. Each parameter  can be changed via the console menus or Telnet. Parameter Default Value System Configuration Management VLAN All IP State USER-CONFIG IP Address 10.1.0.1 NetMark 255.255.0.0 Default Gateway Null User Names admin, guest Password  Screen Timeout 10 min Send Authentication Fail Traps Enabled SNMP Community Name public, private Terminal Baud Rate 19200 Port Configuration Flow Control Di
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        FACTORY DEFAULTS Parameter Default Value Path Cost 4 - 1000Mbps ports 19 - 100Mbps ports 100 - 10Mbps ports Port Priority 128 Spanning Tree Protocol Enabled Spanning Tree Fast Forwarding 10/100 Enabled Mbps ports Virtual LANs Acceptable VLAN Frame Type All Configurable PVID Tagging Yes Untagged VLAN Group Assignment 1 VLAN Ingress Filtering False VLAN Learning SVL 1-5                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        SWITCH MANAGEMENT 1-6                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        CHAPTER 2 USING THE SYSTEM CONFIGURATION PROGRAM Login Screen Once a direct connection to the serial port or a Telnet connection is  established, the login screen for the on-board configuration program  appears as shown below. SSSSSSSSSSSSSSS MMMMM MMMMM CCCCCCCCCCCCCC SSSSSSSSSSSSSSSSS MM MM CCCCCCCCCCCCCCCC SS S MMM MMM CCC CC SS MMMM MMMM CCC SSSSSSSSSSSSSSSS MM MM MM MM CCC SS MM MM MM MM CCC CC SSSMMMMMMMMCCC CC SSSSSSSSSSSSSSSSS MM MMM MM CCCCCCCCCCCCCCCC SSSSSSSSSSSSSSS MMMM MMMMM MMMM CC
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        USING THE SYSTEM CONFIGURATION PROGRAM You should define a new administrator password, record it and put it in a  safe place. Select Console Login Configuration from the Management  Setup Menu and enter a new password for the administrator. Note that  passwords can consist of up to 11 alphanumeric characters and are not  case sensitive. Note: Based on the default configuration, a user is allowed three attempts  to enter the correct password; on the third failed attempt the  current connection is