Resumo do conteúdo contido na página número 1 
                    
                        NetworX NX-548E Receiver
Installation Instructions
466-2225B   July 2006
Copyright © 2006, GE Security Inc.
4. Use the mounting screw provided to loosely install the edge 
Contents
guide standoff in the lower mounting hole in the appropriate 
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
space to the left of the control panel (Figure 2). Do not 
Internal mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
tighten the mounting screw
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        2 NetworX NX-548E Receiver Installation Instructions 6. Align the bottom of the circuit board in the edge guide  Mounting standoff and twist the standoff into place (Figure 4). Tighten  The module can be mounted on any interior wall (protected from  the mounting screw (Figure 2). the elements). To mount the module, do the following: 1. Remove the module back plate from the packaging. Figure 4. Installing the circuit board  2. Hold the base against the mounting surface and mark the  two mounting 
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        3 9. To install the circuit board onto the back plate (Figure 7),  DIP switch settings insert the antennas into the antenna shrouds, then gently  The DIP switches (Figure 7) on the circuit board are used to set  slide the top of the circuit board under the two top latches,  the receiver module number. Use Table 2 to set the DIP switches  and snap the circuit board in at the bottom latch to secure it  to the desired module number. in place. Table 2. DIP switch settings   Module number 32  Module 
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        4 NetworX NX-548E Receiver Installation Instructions 7. Enter the zone number (1 through 192) and press *. Three  Programming beeps from the keypad indicate an entry error. This occurs if  This section describes how to program the units. you enter a transmitter number that is not within the  receiver’s zone block or if the location already has a sensor  Programming guidelines learned into it. Use the following programming guidelines: Note:  If you change your mind about your entry, terminate  • 
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        5 UFT settings Transmitter options Use the following guidelines when setting features 4, 5 and 7  LCD touchpads will display instructions when accomplishing  (see Segment 1 in Table 5 on page 7) for UFTs: tasks. • Feature 4 - Input option 1. For UFTs, turn on this feature to  To program the transmitter and partition settings, do the  disable the transmitter’s primary reed. following: • Feature 5 - Input option 2. For UFTs on this feature to  1. Enter * 8 at the keypad. On LED touchpads, the five
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        6 NetworX NX-548E Receiver Installation Instructions Transmitter supervision windows Delete transmitters LCD touchpads will display instructions when accomplishing tasks. LCD touchpads will display instructions when accomplishing tasks. To change the transmitter supervision windows, do the following: The following section describes how to delete transmitters from  the receiver.  1. Enter * 8 at the keypad. On LED touchpads, the five func- tion lights start flashing. Note:  This procedure makes t
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        7 Table 5. Programming settings (continued) Programming settings table Location Segment 1 Segment 2 Table 5. Programming settings Zone _____ 1 - Enable sensor Partition 1 keyfob  Location Segment 1 Segment 2 2 - Supervised Partition 2 keyfob  Assigned to module  3 - Fire supervision Partition 3 keyfob  0 None None #_____. 4 - Input option 1 Partition 4 keyfob  (Transmitter to   5 - Input option 2 Partition 5 keyfob  program) RM    HE    P 6 - 80-bit device Partition 6 keyfob  7 - Input option 3 
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        8 NetworX NX-548E Receiver Installation Instructions Table 5. Programming settings (continued) Table 5. Programming settings (continued) Location Segment 1 Segment 2 Location Segment 1 Segment 2 Zone _____ 1 - Enable sensor Partition 1 keyfob Zone _____ 1 - Enable sensor Partition 1 keyfob  2 - Supervised Partition 2 keyfob 2 - Supervised Partition 2 keyfob  Assigned to module Assigned to module  3 - Fire supervision Partition 3 keyfob 3 - Fire supervision Partition 3 keyfob  #_____. #_____. 4 -
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        9 Table 5. Programming settings (continued) Table 5. Programming settings (continued) Location Segment 1 Segment 2 Location Segment 1 Segment 2 Zone _____ 1 - Enable sensor Partition 1 keyfob Zone _____ 1 - Enable sensor Partition 1 keyfob  2 - Supervised Partition 2 keyfob 2 - Supervised Partition 2 keyfob  Assigned to module Assigned to module  3 - Fire supervision Partition 3 keyfob 3 - Fire supervision Partition 3 keyfob  #_____. #_____. 4 - Input option 1 Partition 4 keyfob 4 - Input option
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        10 NetworX NX-548E Receiver Installation Instructions Table 5. Programming settings (continued) Table 5. Programming settings (continued) Location Segment 1 Segment 2 Location Segment 1 Segment 2 Zone _____ 1 - Enable sensor Partition 1 keyfob 193 1 - Enable jam detect None Receiver options (all  2 - Supervised Partition 2 keyfob 2 - Enable auto  defaults off) Assigned to module advance to next  3 - Fire supervision Partition 3 keyfob  #_____. zone number  4 - Input option 1 Partition 4 keyfob  
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        11 Table 5. Programming settings (continued) Supported devices For 80-bit devices, Feature 6 must be on for Segment 1 on zone  Location Segment 1 Segment 2 location. For 63-bit devices, Feature 6 must be off for Segment 1  200 None None on zone location. Number of rounds  80-bit devices received from last  transmitter learned • 60-849-02-95 ESL Smoke Detector See Testing and trou- • 60-917-95 Universal Fire Transmitter bleshooting on page 6. • 60-832-95R 2 Button Keychain Touchpad * 63-bit devic
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        12 NetworX NX-548E Receiver Installation Instructions Specifications FCC compliance  This device complies with part 15 of the FCC rules. Operation is subject to the  Compatibility NX-4, NX-6, NX-8, NX-8E control panels following conditions:  Frequency 319.5 MHz 1. This device may not cause harmful interference.  2. This device must accept any interference received, including interference  Wireless range 1,000 feet (304 m) that may cause undesired operation.  Required power 12.0 VDC (provided by