Resumo do conteúdo contido na página número 1 
                    
                         
  LIC022A-R2 LIC026A-R2 LIC054A-R2 
  LIC023A-R2 LIC027A-R2 LIC055A-R2 
  LIC024A-R2 LIC052A-R2 LIC056A-R2 
  LIC025A-R2 LIC053A-R2 LIC057A-R2 
MultiPower Industrial Media Converters 
Choose from four different ways 
to power these hardened media converters. 
                                                                                                                                                                                                                                              
                    
                    Resumo do conteúdo contido na página número 2 
                    
                          TRADEMARKS USED IN THIS MANUAL    Black Box and the Double Diamond logo are registered trademarks of BB  Technologies, Inc.  Any other trademarks mentioned in this manual are acknowledged to be the  property of the trademark owners.                                Page 2 724-746-5500   |   blackbox.com LIC022A-R2                                                                                                                                                                                         
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        FCC and IC RFI Statements    FCC and Industry Canada RF Interference Statements  Class A (using DC terminal power or Power over Ethernet (PoE).  This  equipment has been tested and found to comply with the limits for a Class B  computing device pursuant to Part 15 of the FCC Rules.  These limits are  designed to provide reasonable protection against harmful interference in a  residential installation.  However, there is no guarantee that interference will not  occur in a particular installation.
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Certifications    Certifications         Class 1 Laser product, Luokan 1 Laserlaite,  Laser Klasse 1, Appareil A’Laser de Classe      European Directive 2002/96/EC (WEEE) requires that any equipment that  bears this symbol on product or packaging must not be disposed of with  unsorted municipal waste.  This symbol indicates that the equipment should  be disposed of separately from regular household waste.  It is the  consumer’s responsibility to dispose of this and all equipment so marked  throu
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Table of Contents    Table of Contents    Part Numbers ...................................................................................................... 6  1. Specifications ......................................................................................... 7  2. Overview:  About the MultiPower Industrial Media Converters.............. 8  3. Install the MultiPower Industrial Media Converters................................ 9  3.1 DIN Rail Mounting .....................................
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Part Numbers    Part Numbers    Part Description  Number  LIC022A-R2 TP-TX/FX-MM1300-ST (5 km)  LIC023A-R2 TP-TX/FX-MM1300-SC (5 km)  LIC024A-R2 TP-TX/FX-SM1310/PLUS-ST (30 km)  LIC025A-R2 TP-TX/FX-SM1310/PLUS-SC (30 km)  LIC026A-R2 TP-TX/FX-SM1310/LONG-ST (80 km)  LIC027A-R2 TP-TX/FX-SM1310/LONG-SC (80 km)  LIC052A-R2 TP-TX/SSFX-SM1310-SC (1310xmt/1550rcv) (20km)  LIC053A-R2 TP-TX/SSFX-SM1550-SC (1550xmt/1310rcv) (20km)  LIC054A-R2 TP-TX/SSFX-SM1310/PLUS-SC (1310xmt/1550rcv)  (40km)  LIC055A-R2
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Chapter 1: Specifications    1. Specifications    Ethernet Connections  • 10/100 BaseT  • Auto Negotiation  • Auto-Cross  • Flow Control  • 1916 MTU  • Full Line-Rate Forwarding  DC terminal 7 to 50 VDC, 1 to0.1A  DC (jack) 5 VDC  PoE When MultiPower Industrial Media Converters  use PoE technology to be a PD, the maximum  supply voltage is 50V  AC Wall Adapter 100 to 240 ±10% VAC input, 5 VDC output,  2A max.  Power Consumption 500mA @ 5 VDC  (Typical)  Operating Temperature    DC configurations
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Chapter 2: Overview    2. Overview:  About the MultiPower Industrial Media Converters  The MultiPower Industrial Media Converters provide a single conversion  between 10/100 Base-T twisted pair and 100 Base-SX/FX fiber.  This device  Auto Negotiates speed and duplex on the copper port and the fiber is  100Mbps, FDX.  The unit supports jumbo frames up to 1916 MTU.  The MultiPower Industrial Media Converters are fixed fiber transceiver  models that  include one 10/100 Mbps RJ-45 connector and one 
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        Chapter 3: Install the MultiPower Industrial Media Converters    3. Install the MultiPower Industrial Media Converters  The MultiPower Industrial Media Converters install virtually anywhere as  standalone devices in locations with extremely limited space.  Installation  options include:  • Velcro strips  • DIN rail mounting with DIN Rail clips  • PowerTray/18 for high density applications    3.1 DIN Rail Mounting  The MultiPower Industrial Media Converters ship  from the factory with DIN clips, 
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Chapter 3: Install the MultiPower Industrial Media Converters    3.3 Powering the MultiPower Industrial Media Converters  The MultiPower Industrial Media Converters include multiple powering  options:  • A country-specific, high-reliability AC power adapter (included)  • The IEEE 802.3af Power over Ethernet standard; draws power from  power sourcing equipment  • The 4-terminal DC power block  • IE PowerTray 18-Slot AC for Rack Mounting  • USB cable  • IE-5V DIN rail mount Power Supply  3.4 About
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        Chapter 4: Operation    4. Operation  The MultiPower Industrial Media Converters include two LEDs, located on  the RJ-45 connector.  LED functions are as follows:      LED functions are as follows (above illustration is representative):    FX LNK/ACT Glows green when a link is established on the fiber port;  blinks green when activity is detected on the fiber port.  TX LNK/ACT Glows amber when a link is established on the copper port;  blinks amber when activity is detected on the copper port.  
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Chapter 5: Contacting Black Box    5. Contacting Black Box    Black Box Customer Service  Order toll-free in the U.S.: Call 877-877-BBOX  (outside U.S. call 724-746-5500)  Free technical support, 24 hours a day, 7 days a week.  Call: 724-746-5500 or Fax: 724-746-0746  Mail order: Black Box Corporation  1000 Park Drive, Lawrence, PA 15055-1018  Web site: www.blackbox.com   E-mail: info@blackbox.com      Page 12 724-746-5500   |   blackbox.com LIC022A-R2                                            
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Chapter 6: Fiber Optic Cleaning Guidelines    6. Fiber Optic Cleaning Guidelines    Fiber Optic transmitters and receivers are extremely susceptible to  contamination by particles of dirt or dust, which can obstruct the optic path  and cause performance degradation.  Good system performance requires  clean optics and connector ferrules.  1. Use fiber patch cords (or connectors, if you terminate your own fiber) only  from a reputable supplier; low-quality components can cause many hard-to- diagno
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Chapter 7: Electrostatic Discharge Precautions    7. Electrostatic Discharge Precautions    Electrostatic discharge (ESD) can cause damage to any product, add-in  modules or stand alone units, containing electronic components.  Always  observe the following precautions when installing or handling these kinds of  products.    1. Do not remove unit from its protective packaging until ready to install.  2. Wear an ESD wrist grounding strap before handling any module or  component.  If the wrist str
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        Notes        LIC022A-R2  724-746-5500   |   blackbox.com Page 15                                                                                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 16 
                    
                          LIC022A-R2 Rev. 1 55-80722BB-00 Rev. B3                                                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Resumo do conteúdo contido na página número 17