Resumo do conteúdo contido na página número 1 
                    
                        ENGLISH ES L
See page 2 Vea la página 21
I n s t a l l a t i o n G u i d e
aoñp
™
 90052/90053/90054/90058 Saturn Bath Ventilator with Light 
READ and SAVE THESE INSTRUCTIONS 
	 41718-013/29/2006 			
41718_EngS_3.29.06.indd   1 3/29/06   10:39:57 PM                                                                                                                                                                                                                                                           
                    
                    Resumo do conteúdo contido na página número 2 
                    
                         W a r n i n g TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:  such  as those published by the National Fire Prevention  1. Use  this unit only in a manner intended by the manufacturer.  Association (NFPA), and the American Society for Heating,  If you have questions, contact the manufacturer at the phone  Refrigeration and Air-Conditioning Engineers (ASHRAE), and  number or address listed in the warranty. the local code authorities. 2. Before  installing, servicing, or c
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        95044-01-000 Check all the parts.  D If damaged, call  95029-01-000 1-888-830-1326  E for replacements. 75191-01-000 F x4 A 03242-07-133 G 95491-01-000 H B * 74508-03-133 x2 I 3/8” Cable Connector 95583-01/02/03/04-000 C J * 75184-01-133 K x2 I Extra Screws NOTE: Strain relief cable connector             94990-01/02/03-000 *  L must be installed. Not Included. Included. Tools Needed. (Not supplied) Estimated assembly time: 30 to 60 minutes  Before Installation NOTE:  Remove all packing materials
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        4 3 H E Remove the motor/blower from the housing. Remove packing material. 5 6 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush  with the side of the housing. 7 8 F G Remove the wiring cover screw. Remove the wiring cover. 	 41718-013/29/2006	 			 	 41718-01			3/29/2006 4 41718_EngS_3.29.06.indd   4 3/29/06   10:40:02 PM                                                                                                                                            
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        9 10 E C B Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and  secure with the washer. Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below  go to step D11, page15  New Construction - attaching to joist A12
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        A13 Pull wires through the strain relief. A14 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light   *Option Black Switch 2 (AC In)  *Option Fan & Main Light Together Connect wires as shown. A0 16 A15 E G Connect 4” duct and vent to the outside. Tape joints.  Install the wiring cover plate. Make sure all  If ducting does not fit securely, an adapter may need  wiring connections are inside the box or under  to be purchased. the wir
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        ON OFF 0000 A17 A18 0000 H Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up  into position. Make sure the wires are not pinched  between the motor and the housing. A19 A20 I Secure the motor by tightening the 2 screws. Turn on the power source. A21 A22 Go to step E1 on page 17  to attach grille. Test the motor. If the motor does not run, check the plug  connection. 	 41718-01			3/29/2006	 	 41718-013/29/2006 			 7 41718_EngS_3.29.0
                    
                    Resumo do conteúdo contido na página número 8 
                    
                         New Construction – suspended between joists B12 B11 E D 5/8 5/8 1/2 1/2 Slide the mounting rails into brackets. Position the correct depth mark at the bottom edge of  the joist based on the thickness of your sheetrock.      B13 B14 1/8” Bit E Mark position of screws by using holes as a template. Drill a hole in the center of each outline. B15 B16 Insert screws, leaving space between the screw Attach the rails onto the screws. head and the joist. Screws are not provided. 	 41718-013/29/2006	 			
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        B17 B18 Tighten screws. Pull wires through the strain relief. Ground B19 Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light   *Option Black Switch 2 (AC In)  *Option Fan & Main Light Together Connect wires as shown. B20 B21 F G Connect 4” duct and vent to the outside. Tape joints.  Install the wiring cover plate. Make sure all wiring  If ducting does not fit securely, an adapter may need  connections are inside the box or under the  to
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        ON OFF B22 B23 H H Reinstall the motor by inserting the tabs and pushing up  Connect wiring from the motor to the wiring cover plate. into position. Make sure the wires are not pinched  between the motor and the housing. B24 B25 I Secure the motor by tightening the 2 screws. Turn on the power source. B26 B27 Go to step E1 on page 17  to attach grille. Test the motor. If the motor does not run,  check the plug connection. 	 41718-013/29/2006	 			 	 41718-01			3/29/2006 10 41718_EngS_3.29.06.indd 
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        8”  Existing Construction – accessible from above EXISTING FAN NO EXISTING FAN C11 OR Remove an existing fan and check to make sure the Use the motor housing as a template to mark position. opening is large enough to accommodate the new  motor housing (8”x 8.5”). C12 E D Cut out an opening for the housing. Slide the mounting rails into brackets. C14 C13 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the Mark position of screws by using holes as a template. joist based on t
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        C15 C16 1/8” Bit Drill a hole in the center of each outline. Insert screws, leaving space between the screw head  and the joist. Screws are not provided. C18 C17 Attach the rails onto the screws. Tighten screws. C19 C20 Connect 4” duct and vent to the outside. Tape joints. Pull wires through the strain relief. If ducting does not fit securely, an adapter may  need to be purchased. 	 41718-013/29/2006	 			 	 41718-01			3/29/2006 12 41718_EngS_3.29.06.indd   12 3/29/06   10:40:24 PM               
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        C21 Tighten the strain relief screws. C22 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Light Black Light   *Option Black Switch 2 (AC In)  *Option Fan & Main Light Together Connect wires as shown. C23 C24 H F G Install the wiring cover plate. Make sure all wiring Connect wiring from the motor  connections are inside the box or under the to the wiring cover plate. wiring cover plate. 	 41718-01			3/29/2006	 	 41718-01			3/29/2006 13 41718_En
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        ON OFF C26 C25 I H Reinstall the motor by inserting the tabs and pushing up Secure the motor by tightening the 2 screws. into position. Make sure the wires are not pinched  between the motor and the housing. C27 C28 Test the motor. If the motor does not run,  Turn on the power source. check the plug connection. C29 Go to step E1 on page 17  to attach grille. 	 41718-013/29/2006	 			 	 41718-01			3/29/2006 14 41718_EngS_3.29.06.indd   14 3/29/06   10:40:29 PM                                      
                    
                    Resumo do conteúdo contido na página número 15 
                    
                         Existing Construction – accessible only from below EXISTING FAN D11 D12 E Remove an existing fan and check to make sure the open- Move the housing into position above the ceiling. ing is large enough to accommodate the new motor hous- ing (8”x 8.5”). D13 D14 Attach existing ducting to duct connector. Tape joints. Pull wires through strain relief. If ducting does not fit securely, an adapter may need to be purchased. D15 E Screw pre-loaded screws into joist or framing. 	 41718-013/29/2006	 			 	
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        D16 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Light Black Light   *Option Black Switch 2 (AC In)  *Option Fan & Main Light Together Connect wires as shown. D17 D18 F H G Install the wiring cover plate. Make sure all wiring  Connect wiring from the motor to the wiring cover plate. connections are inside the box or under  the wiring cover plate. D20 D19 I H Secure the motor by tightening the 2 screws.  Reinstall the motor by inserting the 
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        ON OFF D22 D21 Test the motor. If the motor does not run, check the plug  Turn on the power source. connection. D23 Go to step E1 on page 17  to attach grille.  Attaching the Grille E1 E2 E K J Remove the thumbscrews. Connect wiring harness. 	 41718-013/29/2006	 			 	 41718-01			3/29/2006 17 41718_EngS_3.29.06.indd   17 3/29/06   10:40:37 PM                                                                                                                                                             
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        E3 E4 J K Slide light mount over posts. Attach thumbscrews. WARNING: To reduce the risk of electrical shock,  all 4 thumbscrews MUST be properly installed. E5 E6 L Install 2 Max 60 watt A-15 bulbs (Not Included). Align glass dome and push up. E7 Screw glass dome into position. 	 41718-013/29/2006	 			 	 41718-01			3/29/2006 18 41718_EngS_3.29.06.indd   18 3/29/06   10:40:40 PM                                                                                                                         
                    
                    Resumo do conteúdo contido na página número 19 
                    
                         Trouble Shooting Problem: Fan does not come on. Solution:   • Hunter F an Bath Ventilators are extremely quiet.  To confirm that the fan is running, place your hand near the vents to  feel the air movement.    • Turn power on, replace fuse, or reset breaker.    • Check all plug connections to be sure they are secure.    • Check the wiring to make sure it matches the wiring diagram. Problem: Light does not come on.  Solution:    •  Replace the light bulb with a new bulb.    • T urn power on, rep
                    
                    Resumo do conteúdo contido na página número 20 
                    
                         Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath   exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date  of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge  for parts and labor performed